Investigation of concrete compressive strength of existing buildings depending on number of core samples

被引:2
作者
Inel, Mehmet [1 ]
Cayci, Bayram Tanik [1 ]
Ozmen, Hayri Baytan [2 ]
机构
[1] Pamukkale Univ, Engn Fac, Dept Civil Engn, Denizli, Turkey
[2] Usak Univ, Engn Fac, Dept Civil Engn, Usak, Turkey
来源
PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI | 2019年 / 25卷 / 06期
关键词
Concrete compressive strength; Core; Reinforced concrete building; PARAMETERS; DAMAGES;
D O I
10.5505/pajes.2018.00236
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Concrete strength is one of the most critical parameters that affect the seismic performance of reinforced concrete constructions. One of the common methods to determine the concrete compressive strength is to take core samples from structural members. However, the number of taken core samples-based on the size of the construction-is important for reliable results, especially in old constructions. This study aims to investigate the possibility of determination of the concrete compressive strength values of existing buildings using lower number of core samples than the required number of cores. For this purpose, experimental results of core samples taken from 148 slightly or moderately damaged reinforced concrete buildings during 2011 Simav Earthquake. Concrete compressive strength values based on 15 different sets obtained by using 50% and 70% of the core samples of each building are compared. The compressive strength values calculated from the sets were compared with the average compressive strengths of all core samples to investigate accuracy of estimation of compressive strength with using lower number of core samples. The study also investigates whether there is a significant difference between samples taken from a single story (i.e. ground story) compared to the whole building. It is concluded that the use of %50 of the required core samples is possible for the rapid assessment or large-scale field investigation studies when the obtained concrete strength is equal to or greater than 8 MPa. However, additional core samples to complete 70% of the code required samples are required for concrete strength values lower than 8 MPa.
引用
收藏
页码:621 / 626
页数:6
相关论文
共 12 条
[1]  
[Anonymous], 1999, C42C42M99 ASTM
[2]  
[Anonymous], 2000, Prestandard and Commentary for the Seismic Rehabilitation of Buildings
[3]  
Binici H., 2000, Pamukkale Univ. J. Eng. Sci., V6, P203
[4]  
CEN (European Comittee for Standardisation), 2004, EUR 8 DES STRUCT E 3
[5]  
Disaster and Emergency Management Presidency (DEMP), 2011, BUILD DAM RES KUT
[6]  
Inel M, 2011, REPORT DISASTER EMER
[7]   Observations on the building damages after 19 May 2011 Simav (Turkey) earthquake [J].
Inel, Mehmet ;
Ozmen, Hayri Baytan ;
Akyol, Erdal .
BULLETIN OF EARTHQUAKE ENGINEERING, 2013, 11 (01) :255-283
[8]   Evaluation of the main parameters affecting seismic performance of the RC buildings [J].
Ozmen, Hayri Baytan ;
Inel, Mehmet ;
Meral, Emrah .
SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2014, 39 (02) :437-450
[9]   Evaluations on the relation of RC building damages with structural parameters after May 19, 2011 Simav (Turkey) earthquake [J].
Ozmen, Hayri Baytan ;
Inel, Mehmet ;
Akyol, Erdal ;
Cayci, Bayram Tanik ;
Un, Hayri .
NATURAL HAZARDS, 2014, 71 (01) :63-84
[10]  
*TS, 1992, 10465 TS