New Sol-Gel Hybrid Material in Solid Phase Extraction Combined with Liquid Chromatography for the Determination of Non-steroidal Anti-inflammatory Drugs in Water Samples

被引:19
作者
Abd Rahim, Mashkurah [1 ]
Ibrahim, Wan Aini Wan [1 ,2 ]
Ramli, Zainab [1 ]
Sanagi, Mohd Marsin [1 ,3 ]
Aboul-Enein, Hassan Y. [4 ]
机构
[1] Univ Teknol Malaysia, Dept Chem, Fac Sci, Utm Johor Bahru 81310, Johor, Malaysia
[2] Univ Teknol Malaysia, Separat Sci & Technol Grp, Frontier Mat Res Alliance, Utm Johor Bahru 81310, Johor, Malaysia
[3] Univ Teknol Malaysia, Ibnu Sina Inst Sci & Ind Res, Utm Johor Bahru 81310, Johor, Malaysia
[4] Natl Res Ctr, Pharmaceut & Med Dept, Pharmaceut & Drug Ind Res Div, Giza 12622, Egypt
关键词
Sol-gel; Organic-inorganic hybrid; Solid phase extraction; Non-steroidal anti-inflammatory drugs; High performance liquid chromatography; METHYLTRIMETHOXYSILANE-TETRAETHOXYSILANE; SORBENT; FIBER; POLYDIMETHYLSILOXANE; DICLOFENAC; IBUPROFEN; COATINGS; PLASMA; SILICA; HPLC;
D O I
10.1007/s10337-016-3059-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new sol-gel hybrid methyltrimethoxysilane-mercaptopropyltrimethoxysilane (MTMOS-MPTMS) was synthesized, characterized and applied as sorbent for solid phase extraction (SPE) of selected non-steroidal anti-inflammatory drugs (NSAIDs) as target analytes. Analysis was performed using high performance liquid chromatography with UV detection at 234 nm. Under the optimum extraction conditions (100 mg sorbent, 20 mL sample loading volume and 7 mL acetonitrile as desorption eluent), the method using the sol-gel organic-inorganic hybrid MTMOS-MPTMS as SPE sorbent showed good linearity in the range of 1-550 mu g L-1, good repeatability (RSD 1.4-6.0 %, n = 3), low limits of detection at S/N = 3 (0.10-0.29 mu g L-1) and limit of quantification (0.330.89 mu g L-1, S/N = 10). The developed MTMOS-MPTMS SPE method was successfully applied to real sample analysis of the selected NSAIDs from several water samples. In-house MTMOS-MPTMS sol-gel hybrid material was able to extract the selected NSAIDs (diclofenac sodium, ketoprofen, mefenamic acid) in water samples comparable to commercial cyano sorbent. Excellent relative recoveries (RR) and RSDs of the NSAIDs were obtained from the various water samples (RR: 85.8-104.2 %, RSDs 1.2-6.0 %, n = 3) using the MTMOS-MPTMS SPE sorbent. The sol-gel hybrid MTMOS-MPTMS SPE sorbent demonstrates promising potential as an alternative inexpensive extraction sorbent for NSAIDs from water samples and with higher selectivity.
引用
收藏
页码:421 / 429
页数:9
相关论文
共 28 条
[1]   Analyses of Nonsteroidal Anti-inflammatory Drugs in Human Plasma Using Dispersive Nano Solid-Phase Extraction and High-Performance Liquid Chromatography [J].
Ali, Imran ;
Kulsum, Umma ;
AL-Othman, Zeid A. ;
Saleem, Kishwar .
CHROMATOGRAPHIA, 2016, 79 (3-4) :145-157
[2]   Optimization of the derivatization reaction and the solid-phase microextraction conditions using a D-optimal design and three-way calibration in the determination of non-steroidal anti-inflammatory drugs in bovine milk by gas chromatography-mass spectrometry [J].
Arroyo, David ;
Ortiz, M. Cruz ;
Sarabia, Luis A. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (28) :4487-4497
[3]   Sol-gel-based SPME and GC-MS for trace determination of geosmin in water and apple juice samples [J].
Bagheri, Habib ;
Aghakhani, Ali ;
Es-haghi, Ali .
CHROMATOGRAPHIA, 2007, 66 (9-10) :779-783
[4]   Functional coatings: The sol-gel approach [J].
Belleville, Philippe .
COMPTES RENDUS CHIMIE, 2010, 13 (1-2) :97-105
[5]   Applications of monolithic solid-phase extraction in chromatography-based clinical chemistry assays [J].
Bunch, Dustin R. ;
Wang, Sihe .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (10) :3021-3033
[6]   Molecularly imprinted silica as a selective SPE sorbent for triazine herbicides [J].
Costa Silva, Raquel Gomes ;
Morais Vigna, Camila Rosa ;
Bottoli, Carla B. G. ;
Collins, Carol H. ;
Augusto, Fabio .
JOURNAL OF SEPARATION SCIENCE, 2010, 33 (09) :1319-1324
[7]   Development of novel sol-gel coatings by chemically bonded ionic liquids for stir bar sorptive extraction-application for the determination of NSAIDS in real samples [J].
Fan, Wenying ;
Mao, Xiangju ;
He, Man ;
Chen, Beibei ;
Hu, Bin .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (28) :7261-7273
[8]  
FDA, 1998, GUID IND ENV ASS HUM
[9]   Multi-residue determination of non-steroidal anti-inflammatory drug residues in animal serum and plasma by HPLC and photo-diode array detection [J].
Gallo, Pasquale ;
Fabbrocino, Serena ;
Vinci, Floriana ;
Fiori, Maurizio ;
Danese, Vincenzo ;
Nasi, Antonella ;
Serpe, Luigi .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2006, 44 (10) :585-590
[10]  
Galuszka A, 2012, TRENDS ANAL CHEM, V50, P78