T2-weighted spine Imaging with a fast three-point Dixon technique: Comparison with chemical shift selective fat suppression

被引:48
作者
Ma, JF
Singh, SK
Kumar, AJ
Leeds, NE
Zhan, JP
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
关键词
magnetic resonance imaging; chemical shift; fat suppression; image processing; phased array; spine imaging;
D O I
10.1002/jmri.20201
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a phased-array coil-compatible, fast three-point Dixon (TPD) technique, and compare its performance in T2-weighted spine imaging with that of the standard chemical shift selective (CHESS) fat suppression technique. Materials and Methods: We acquired T2-weighted spine images of 27 patients using essentially identical scanning parameters with the fast TPD technique and standard fast spin echo (FSE) with CHESS fat suppression. A phased-array coil-compatible image reconstruction algorithm was developed to generate separate water and fat images from the data acquired with the fast TPD technique. Three neuroradiologists independently scored the images from the two different techniques for uniformity of fat suppression and lesion conspicuity using a four-point system (1 = poor, 2 = fair, 3 = good, 4 = best). Results: The reviewers' mean scores were 3.2 and 2.1 for the uniformity of fat suppression, and 3.0 and 2.0 for the lesion conspicuity for the fast TPD and the CHESS fat suppression techniques, respectively. The fast TPD technique was statistically superior to the CHESS technique at P < 0.0005. Conclusion: The fast TPD technique provides superior fat suppression and lesion conspicuity, and potentially can be used as an alternative to T2-weighted imaging of the spine. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:1025 / 1029
页数:5
相关论文
共 16 条
[1]   MR IMAGING - CLINICAL USE OF THE INVERSION RECOVERY SEQUENCE [J].
BYDDER, GM ;
YOUNG, IR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :659-675
[2]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[3]   CHEMICAL-SHIFT SELECTIVE MR IMAGING USING A WHOLE-BODY MAGNET [J].
FRAHM, J ;
HAASE, A ;
HANICKE, W ;
MATTHAEI, D ;
BOMSDORF, H ;
HELZEL, T .
RADIOLOGY, 1985, 156 (02) :441-444
[4]   MULTIPOINT DIXON TECHNIQUE FOR WATER AND FAT PROTON AND SUSCEPTIBILITY IMAGING [J].
GLOVER, GH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (05) :521-530
[5]   3-POINT DIXON TECHNIQUE FOR TRUE WATER FAT DECOMPOSITION WITH BO INHOMOGENEITY CORRECTION [J].
GLOVER, GH ;
SCHNEIDER, E .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :371-383
[6]   SEPARATION OF FAT AND WATER IN FAST SPIN-ECHO MR-IMAGING WITH THE 3-POINT DIXON TECHNIQUE [J].
HARDY, PA ;
HINKS, RS ;
TKACH, JA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (02) :181-185
[7]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833
[8]  
JONES KM, 1994, AM J NEURORADIOL, V15, P401
[9]   Method for efficient fast spin echo Dixon imaging [J].
Ma, JF ;
Singh, SK ;
Kumar, AJ ;
Leeds, NE ;
Broemeling, LD .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (06) :1021-1027
[10]   THE NMR PHASED-ARRAY [J].
ROEMER, PB ;
EDELSTEIN, WA ;
HAYES, CE ;
SOUZA, SP ;
MUELLER, OM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :192-225