Heat Transfer in Radially Rotating Pin-Fin Channel at High Rotation Numbers

被引:36
作者
Chang, Shyy Woei [1 ]
Liou, Tong-Miin [2 ]
Yang, Tsun Lirng [3 ]
Hong, Guo Fang [3 ]
机构
[1] Natl Kaohsiung Marine Univ, Dept Marine Engn, Thermal Fluids Lab, Kaohsiung 811, Taiwan
[2] Natl Tsing Hua Univ, Dept Power Mech Engn, Hsinchu 300, Taiwan
[3] Natl Kaohsiung Marine Univ, Kaohsiung 81143, Taiwan
来源
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME | 2010年 / 132卷 / 02期
关键词
boundary layer turbulence; channel flow; heat transfer; rotational flow; RIB TURBULATORS; CROSS-SECTIONS; SQUARE DUCT; FLOW; ARRAYS; OPTIMIZATION; TRANSVERSE; ENDWALL;
D O I
10.1115/1.3147103
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Endwall heat transfer measurements for a radially rotating rectangular pin-fin channel with the width-to-height ratio (aspect ratio) of 8 are performed at the parametric conditions of 5000 < Re < 20,000, 0 < Ro < 1.4, and 0.1 <Delta rho/rho < 0.21. Centerline heat transfer levels along the leading and trailing endwalls of the rotating pin-fin channel are, respectively, raised to 1.77-3.72 and 3.06-5.2 times of the Dittus-Boelter values. No previous attempt has examined the heat transfer performances for the pin-fin channel at such high rotation numbers. A selection of experimental data illustrates the individual and interactive Re, Ro, and buoyancy number (Bu) effects on heat transfer. Spanwise heat transfer variations between two adjoining pin rows are detected with the averaged Nusselt numbers (Nu) determined. A set of empirical equations that calculates Nu values over leading and trailing endwalls in the developed flow region is derived to correlate all the heat transfer data generated by this study and permits the evaluation of interactive and individual effects of Re, Ro, and Bu on Nu. With the aid of the Nu correlations derived, the operating conditions with the worst heat transfer scenarios for this rotating pin-fin channel are identified.
引用
收藏
页数:12
相关论文
共 32 条
[1]   Heat transfer in a rotating twin-pass trapezoidal-sectioned passage roughened by skewed ribs on two opposite walls [J].
Chang, Shyy Woei ;
Yang, Tsun Lirng ;
Wang, Wei Jen .
HEAT TRANSFER ENGINEERING, 2006, 27 (10) :63-79
[2]   Heat transfer in a radially rotating square duct fitted with in-line transverse ribs [J].
Chang, SW ;
Morris, WD .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2003, 42 (03) :267-282
[3]   A comparative study of heat transfer between rotating circular smooth-walled and square rib-roughened ducts with cooling application for gas turbine rotor blades [J].
Chang, SW ;
Morris, WD .
JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1998, 41 (02) :302-315
[4]  
CHANG SW, 2007, ASME, V129, P188, DOI DOI 10.1115/1.2409988
[5]  
CHANG SW, 2008, ASME, V130
[6]  
Chyu M. K., 2007, ASME Paper No. GT2007-28138
[7]   Heat transfer contributions of pins and endwall in pin-fin arrays: Effects of thermal boundary condition modeling [J].
Chyu, MK ;
Hsing, YC ;
Shih, TIP ;
Natarajan, V .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1999, 121 (02) :257-263
[8]   Heat transfer on the base surface of three-dimensional protruding elements [J].
Chyu, MK ;
Natarajan, V .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1996, 39 (14) :2925-2935
[9]   HEAT-TRANSFER AND PRESSURE-DROP FOR SHORT PIN-FIN ARRAYS WITH PIN-ENDWALL FILLET [J].
CHYU, MK .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1990, 112 (04) :926-932
[10]  
Dittus FW, 1930, U CALIFORNIA PUBLICA, V2