An improved control method of fault ride-through for DPMWT-based wind farm considering coupling effect of HVDC transmission system

被引:5
作者
Ouyang, Jinxin [1 ]
Yu, Jianfeng [1 ]
Pang, Mingyu [1 ]
Diao, Yanbo [2 ]
机构
[1] Chongqing Univ, Sch Elect Engn, State Key Lab Power Transmiss Equipment & Syst Sec, Peoples Republ China, Chongqing 400044, Peoples R China
[2] Chongqing City Management Coll, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
DPMWT; Wind farm; HVDC; Fault ride-through; Reactive power control; COMMUTATION FAILURE; CONTROL STRATEGY; VOLTAGE; PERFORMANCE; TURBINE; DESIGN;
D O I
10.1016/j.ijepes.2022.108064
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the continuous increase of wind power penetration, a large number of wind farm have been constructed. The large-scale wind farm is usually transmitted through high voltage direct current(HVDC) transmission system. The reactive power output on the grid-side converter is utilized to support grid voltage, which is a common method of fault ride-through for direct-drive permanent magnet synchronous generator-based wind turbine (DPMWT). The power control capability of DPMWT-based wind farm(DPMWF) is affected by safety constraints and operating characteristics of the external system. However, the control strategy of DPMWF cannot yet take into account the coupling effect of HVDC and may be difficult to meet the voltage recovery requirements of the grid during the grid fault. Even the DPMWT may oscillate due to the over-threshold of the control setting value. Therefore, a power coupling model between DPMWF and rectifier station of HVDC transmission system is established, and an evaluation method for the power controllability of DPMWF under fault considering the coupling effect of HVDC transmission system is proposed. A calculation method of maximum reference value of reactive power control of DPMWF based on model predictive control is proposed taking into account the con-verter constraints of DPMWF and the influence of the external system. An improved control method of fault ride-through is further proposed, which takes into account the coupling effect of HVDC transmission system. The simulation shows that the proposed method can improve the voltage recovery characteristics under the grid fault, effectively guarantee the fault ride-through of DPMWF.
引用
收藏
页数:8
相关论文
共 50 条
[41]   Fault Ride-Through and Power Smoothing Control of PMSG-Based Wind Generation Using Supercapacitor Energy Storage System [J].
Muhammed Y. Worku ;
M. A. Abido .
Arabian Journal for Science and Engineering, 2019, 44 :2067-2078
[42]   Enhancement of demagnetization control for low-voltage ride-through capability in DFIG-based wind farm [J].
Dosoglu, M. Kenan ;
Guvenc, Ugur ;
Sonmez, Yusuf ;
Yilmaz, Cemal .
ELECTRICAL ENGINEERING, 2018, 100 (02) :491-498
[43]   Fault Ride-Through for PMVG-Based Wind Turbine System Using Coordinated Active and Reactive Power Control Strategy [J].
Palanimuthu, Kumarasamy ;
Mayilsamy, Ganesh ;
Lee, Seong Ryong ;
Jung, Sang Yong ;
Joo, Young Hoon .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (06) :5797-5807
[44]   Steady-state control and fault ride-through method of IPC-CSC for offshore wind integration [J].
Feng, Dingteng ;
Xiong, Xiaoling ;
Yao, Chenhao ;
Zhao, Chengyong .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 162
[45]   Protection and fault ride-through techniques of VSC-HVDC systems for offshore wind power transmission-Research status, challenges, and prospects [J].
He, Jiawei ;
Xue, Lei ;
Li, Bin ;
Li, Ye ;
Prieto-Araujo, Eduardo ;
Gomis-Bellmunt, Oriol .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2025, 210
[46]   DC Pole-to-ground Fault Ride-through Strategy of Hybrid HVDC System Based on LCC and Hybrid MMC [J].
Zhang D. ;
Fan Z. ;
Xu H. ;
Miao S. ;
Wang Y. ;
Liu Z. .
Gaodianya Jishu/High Voltage Engineering, 2020, 46 (06) :2072-2080
[47]   Improved Fault -Ride -Through Control Scheme without Requiring Fault -Detection System for a Doubly Fed Induction Generator in a Wind System [J].
Papagiannis, Dimitrios ;
Kosseoglou, Markos ;
Tsioumas, Evangelos ;
Jabbour, Nikolaos ;
Karlis, Athanasios ;
Mademlis, Christos ;
Solomin, Evgeny .
2020 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), VOL 1, 2020, :1349-1355
[48]   Smoothing of Wind Power Fluctuations for Permanent Magnet Synchronous Generator-Based Wind Energy Conversion System and Fault Ride-through Consideration [J].
Pratap, Alok ;
Ziadi, Zakaria ;
Urasaki, Naomitsu ;
Senjyu, Tomonobu .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2015, 43 (03) :271-281
[49]   A Flywheel Energy Storage System for Fault Ride Through Support of Grid-Connected VSC HVDC-Based Offshore Wind Farms [J].
Daoud, Mohamed I. ;
Massoud, Ahmed M. ;
Abdel-Khalik, Ayman Samy ;
Elserougi, Ahmed ;
Ahmed, Shehab .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (03) :1671-1680
[50]   Advanced Fault Ride-Through Operation Strategy Based on Model Predictive Control for High Power Wind Turbine [J].
Catalan, Pedro ;
Wang, Yanbo ;
Arza, Joseba ;
Chen, Zhe .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2024, 15 (01) :513-526