Rapid acquisition of magnetic resonance imaging of the shoulder using three-dimensional fast spin echo sequence with compressed sensing

被引:31
作者
Lee, Seung Hyun [1 ,2 ,3 ]
Lee, Young Han [1 ,2 ]
Song, Ho-Taek [1 ,2 ]
Suh, Jin-Suck [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Med Convergence Res Inst, Dept Radiol,Res Inst Radiol Sci, 50-1 Yonsei Ro, Seoul 03722, South Korea
[2] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, 50-1 Yonsei Ro, Seoul 03722, South Korea
[3] Ilsan Hosp, Dept Radiol, Natl Hlth Insurance Serv, 100 Ilsan Ro, Goyang Si 10444, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Shoulder; MRI; 3D fast spin echo; Compressed sensing; Fast imaging; FAT-SUPPRESSION; MRI; MOTION; KNEE;
D O I
10.1016/j.mri.2017.07.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility of 3D fast spin-echo (FSE) imaging with compressed sensing (CS) for the assessment of shoulder. Materials and methods: Twenty-nine patients who underwent shoulder MRI including image sets of axial 3D-FSE sequence without CS and with CS, using an acceleration factor of 1.5, were included. Quantitative assessment was performed by calculating the root mean square error (RMSE) and structural similarity index (SSIM). Two musculoskeletal radiologists compared image quality of 3D-FSE sequences without CS and with CS, and scored the qualitative agreement between sequences, using a five-point scale. Diagnostic agreement for pathologic shoulder lesions between the two sequences was evaluated. Results: The acquisition time of 3D-FSE MRI was reduced using CS (3 min 23 s vs. 2 min 22 s). Quantitative evaluations showed a significant correlation between the two sequences (r = 0.872-0.993, p<0.05) and SSIM was in an acceptable range (0.940-0.993; mean standard deviation, 0.968 +/- 0.018). Qualitative image quality showed good to excellent agreement between 3D-FSE images without CS and with CS. Diagnostic agreement for pathologic shoulder lesions between the two sequences was very good (kappa = 0.915-1). Conclusions: The 3D-FSE sequence with CS is feasible in evaluating the shoulder joint with reduced scan time compared to 3D-FSE without CS. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:152 / 157
页数:6
相关论文
共 22 条
[1]   Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information [J].
Candès, EJ ;
Romberg, J ;
Tao, T .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) :489-509
[2]   Fat suppression in MR imaging: Techniques and pitfalls [J].
Delfaut, EM ;
Beltran, J ;
Johnson, G ;
Rousseau, J ;
Marchandise, X ;
Cotten, A .
RADIOGRAPHICS, 1999, 19 (02) :373-382
[3]   Compressed sensing [J].
Donoho, DL .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (04) :1289-1306
[4]   Six-Fold Acceleration of High-Spatial Resolution 3D SPACE MRI of the Knee Through Incoherent k-Space Undersampling and Iterative ReconstructionFirst Experience [J].
Fritz, Jan ;
Raithel, Esther ;
Thawait, Gaurav K. ;
Gilson, Wesley ;
Papp, Derek F. .
INVESTIGATIVE RADIOLOGY, 2016, 51 (06) :400-409
[5]  
Gonzalez R.C., 1987, Digital image processing, P503
[6]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[7]  
Guobin Li DP, 2012, P 20 ANN M ISMRM MEL
[8]   Compressed sensing MRI: a review of the clinical literature [J].
Jaspan, Oren N. ;
Fleysher, Roman ;
Lipton, Michael L. .
BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1056)
[9]   Three-dimensional Isotropic Shoulder MR Arthrography: Comparison with Two-dimensional MR Arthrography for the Diagnosis of Labral Lesions at 3.0 T [J].
Jung, Jee Young ;
Yoon, Young Cheol ;
Choi, Sang-Hee ;
Kwon, Jong Won ;
Yoo, Jaechul ;
Choe, Bong-Keun .
RADIOLOGY, 2009, 250 (02) :498-505
[10]   Routine 3D Magnetic Resonance Imaging of Joints [J].
Kijowski, Richard ;
Gold, Garry E. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) :758-771