Comparison of single-coil lead versus dual-coil lead of implantable cardioverter defibrillator on lead-related venous complications in a canine model

被引:2
|
作者
Yu, Ziqing [1 ,2 ,3 ]
Wu, Yuan [1 ]
Qin, Shengmei [1 ,2 ]
Wang, Jingfeng [1 ,2 ]
Chen, Xueying [1 ,2 ]
Chen, Ruizhen [1 ,4 ]
Su, Yangang [1 ,2 ]
Ge, Junbo [1 ]
机构
[1] Fudan Univ, Shanghai Inst Cardiovasc Dis, Zhongshan Hosp, Dept Cardiol, 180 Fenglin Rd, Shanghai 200032, Peoples R China
[2] Shanghai Inst Med Imaging, Shanghai 200032, Peoples R China
[3] Fudan Univ, Shanghai Med Coll, Shanghai 200032, Peoples R China
[4] Fudan Univ, Shanghai Inst Cardiovasc Dis, Key Lab Viral Heart Dis, Dept Cardiovasc Dis,Zhongshan Hosp,Minist Publ Hl, Shanghai 200032, Peoples R China
基金
中国国家自然科学基金;
关键词
Single-coil lead; Dual-coil lead; Implantable cardioverter defibrillator; Stenosis; Fibrosis; ICD; EXPERIENCE; PREDICTORS; PACEMAKER; OUTCOMES; PATIENT; DEVICE;
D O I
10.1007/s10840-018-0312-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The DCL was proved to increase thrombosis, fibrosis, and stenosis in the SVC. Likewise, the DCL was mechanically harder to be extracted than the SCL. Our study showed that lead-related complications of the DCLs were higher than those of the SCLs regardless of the equal defibrillation thresholds between them. Results of the present study would help to choose the proper lead which could be removed.
引用
收藏
页码:195 / 201
页数:7
相关论文
共 40 条
  • [31] Low Defibrillation Threshold in a Patient with a Dual-Coil Defibrillator Lead Implanted through a Persistent Left Superior Vena Cava
    Williams, Thomas A., Jr.
    Abe, Oluwole
    Mitre, Cristina A.
    Kassotis, John
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (09): : e274 - e275
  • [32] Multicentre comparison Of shock efficacy using single-vs. Dual-coil lead systems and Anodal vs. cathodaL polarITY defibrillation in patients undergoing transvenous cardioverter-defibrillator implantation. The MODALITY study
    Baccillieri, Maria Stella
    Gasparini, Gianni
    Benacchio, Luca
    Zorzi, Alessandro
    Marras, Elena
    Zerbo, Francesca
    Tomasi, Luca
    Vaccari, Diego
    Pastore, Gianni
    Bonanno, Carlo
    Molon, Giulio
    Zanotto, Gabriele
    Fusco, Antonio
    Carasi, Massimo
    Zorzi, Andrea
    Calzolari, Vittorio
    Ignatiuk, Barbara
    Cannas, Sergio
    Vaglio, Alessandro
    Al Bunni, Muhamad
    Pedrini, Antonella
    Olivieri, Armando
    Rampazzo, Roberta
    Minicuci, Nadia
    Corrado, Domenico
    Verlato, Roberto
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2015, 43 (01) : 45 - 54
  • [33] Multicentre comparison Of shock efficacy using single-vs. Dual-coil lead systems and Anodal vs. cathodaL polarITY defibrillation in patients undergoing transvenous cardioverter-defibrillator implantation. The MODALITY study
    Maria Stella Baccillieri
    Gianni Gasparini
    Luca Benacchio
    Alessandro Zorzi
    Elena Marras
    Francesca Zerbo
    Luca Tomasi
    Diego Vaccari
    Gianni Pastore
    Carlo Bonanno
    Giulio Molon
    Gabriele Zanotto
    Antonio Fusco
    Massimo Carasi
    Andrea Zorzi
    Vittorio Calzolari
    Barbara Ignatiuk
    Sergio Cannas
    Alessandro Vaglio
    Muhamad Al Bunni
    Antonella Pedrini
    Armando Olivieri
    Roberta Rampazzo
    Nadia Minicuci
    Domenico Corrado
    Roberto Verlato
    Journal of Interventional Cardiac Electrophysiology, 2015, 43 : 45 - 54
  • [34] Effectiveness and safety of transvenous extraction of single- versus dual-coil implantable cardioverter-defibrillator leads at single-center experience (vol 98, e16548, 2020)
    Zabek, A.
    Boczar, K.
    Debski, M.
    MEDICINE, 2020, 99 (03)
  • [35] Comparison study on sensing and identification of Single-Lead Atrial Sensing System, Single-Chamber and Dual-Chamber Implantable Cardioverter Defibrillator System
    Long, Qilin
    Sun, Jie
    Dong, Jianting
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (16) : C135 - C135
  • [36] Isolated subcutaneous implantable cardioverter-defibrillator generator displacement causing inappropriate shocks despite preserved lead tip and coil position: a case report
    Chow, Ji-Jian
    Bilham, James
    Lane, Rebecca
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2023, 7 (02)
  • [37] TEMPORAL TRENDS IN AND FACTORS ASSOCIATED WITH SINGLE VERSUS DUAL COIL IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR LEADS: DATA FROM THE NCDR ICD REGISTRY
    Pokorney, Sean
    Parzynski, Craig
    Daubert, James
    Hegland, Donald
    Varosy, Paul
    Curtis, Jeptha
    Al-Khatib, Sana
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A331 - A331
  • [38] Prognosis after lead extraction in patients with cardiac implantable electronic devices infection: Comparison of lead-related infective endocarditis with pocket infection in a Japanese single-center experience
    Nishii, Nobuhiro
    Morimoto, Yoshimasa
    Miyoshi, Akihito
    Tsukuda, Saori
    Miyamoto, Masakazu
    Kawada, Satoshi
    Nakagawa, Koji
    Watanabe, Atsuyuki
    Nakamura, Kazufumi
    Morita, Hiroshi
    Morimatsu, Hiroshi
    Kusano, Nobuchika
    Kasahara, Shingo
    Shoda, Morio
    Ito, Hiroshi
    JOURNAL OF ARRHYTHMIA, 2019, 35 (04) : 654 - 663
  • [39] Comparison of a Novel, Single-Lead Atrial Sensing System With a Dual-Chamber Implantable Cardioverter-Defibrillator System in Patients Without Antibradycardia Pacing Indications Results of a Randomized Study
    Sticherling, Christian
    Zabel, Markus
    Spencker, Sebastian
    Meyerfeldt, Udo
    Eckardt, Lars
    Behrens, Steffen
    Niehaus, Michael
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (01): : 56 - 63
  • [40] Impact of remote monitoring on reducing the burden of inappropriate shocks related to implantable cardioverter-defibrillator lead fractures: insights from a French single-centre registry
    Souissi, Zouheir
    Guedon-Moreau, Laurence
    Boule, Stephane
    Kouakam, Claude
    Finat, Loic
    Marquie, Christelle
    Brigadeau, Francois
    Wissocque, Ludivine
    Mouton, Stephanie
    Montaigne, David
    Klug, Didier
    Kacet, Salem
    Lacroix, Dominique
    EUROPACE, 2016, 18 (06): : 820 - 827