Comparison of single-coil lead versus dual-coil lead of implantable cardioverter defibrillator on lead-related venous complications in a canine model

被引:2
|
作者
Yu, Ziqing [1 ,2 ,3 ]
Wu, Yuan [1 ]
Qin, Shengmei [1 ,2 ]
Wang, Jingfeng [1 ,2 ]
Chen, Xueying [1 ,2 ]
Chen, Ruizhen [1 ,4 ]
Su, Yangang [1 ,2 ]
Ge, Junbo [1 ]
机构
[1] Fudan Univ, Shanghai Inst Cardiovasc Dis, Zhongshan Hosp, Dept Cardiol, 180 Fenglin Rd, Shanghai 200032, Peoples R China
[2] Shanghai Inst Med Imaging, Shanghai 200032, Peoples R China
[3] Fudan Univ, Shanghai Med Coll, Shanghai 200032, Peoples R China
[4] Fudan Univ, Shanghai Inst Cardiovasc Dis, Key Lab Viral Heart Dis, Dept Cardiovasc Dis,Zhongshan Hosp,Minist Publ Hl, Shanghai 200032, Peoples R China
基金
中国国家自然科学基金;
关键词
Single-coil lead; Dual-coil lead; Implantable cardioverter defibrillator; Stenosis; Fibrosis; ICD; EXPERIENCE; PREDICTORS; PACEMAKER; OUTCOMES; PATIENT; DEVICE;
D O I
10.1007/s10840-018-0312-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The DCL was proved to increase thrombosis, fibrosis, and stenosis in the SVC. Likewise, the DCL was mechanically harder to be extracted than the SCL. Our study showed that lead-related complications of the DCLs were higher than those of the SCLs regardless of the equal defibrillation thresholds between them. Results of the present study would help to choose the proper lead which could be removed.
引用
收藏
页码:195 / 201
页数:7
相关论文
共 40 条
  • [1] Comparison of single-coil lead versus dual-coil lead of implantable cardioverter defibrillator on lead-related venous complications in a canine model
    Ziqing Yu
    Yuan Wu
    Shengmei Qin
    Jingfeng Wang
    Xueying Chen
    Ruizhen Chen
    Yangang Su
    Junbo Ge
    Journal of Interventional Cardiac Electrophysiology, 2018, 52 : 195 - 201
  • [2] Clinical outcomes of patient with single-coil vs. dual-coil implantable cardioverter defibrillation lead for secondary prevention
    Korai, K.
    Ishibashi, K.
    Kamakura, T.
    Wada, M.
    Yamagata, K.
    Inoue, Y.
    Miyamoto, K.
    Nagase, S.
    Noda, T.
    Aiba, T.
    Noguchi, T.
    Yasuda, S.
    Kusano, K.
    EUROPEAN HEART JOURNAL, 2018, 39 : 1226 - 1226
  • [3] Lead-related complications in 340 patients with an implantable cardioverter/defibrillator
    Schwacke, H
    Drögemüller, A
    Siemon, G
    Werling, C
    Saggau, W
    Senges, J
    Seidl, K
    ZEITSCHRIFT FUR KARDIOLOGIE, 1999, 88 (08): : 559 - 565
  • [4] Outcomes with single-coil versus dual-coil implantable cardioverter defibrillators: a meta-analysis
    Sunderland, Nicholas
    Kaura, Amit
    Murgatroyd, Francis
    Dhillon, Para
    Scott, Paul A.
    EUROPACE, 2018, 20 (03): : E21 - E29
  • [5] Comparison of Single-Coil Versus Dual-Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta-Analysis of Efficacy and Extraction-Related Outcomes
    Tahir, Muhammad Fawad
    Maryyum, Adeena
    Mubbashir, Zainab
    Khan, Abdul Moiz
    Imam, Syed Irtiza
    Mustafa, Fatima
    Hasan, Syeda Zahra
    Shoaib, Umer
    Iqbal, Areej
    Saeed, Osama
    Purushotham, Manisha
    Khan, Maimoona
    Tariq, Shahtaj
    Larik, Muhammad Omar
    Anjum, Muhammad Umair
    Hasanain, Muhammad
    Ayyalu, Tanesh
    Changez, Mah I. Kan
    Iqbal, Javed
    CLINICAL CARDIOLOGY, 2025, 48 (02)
  • [6] OUTCOMES WITH SINGLE-COIL VERSUS DUAL-COIL IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS: A META-ANALYSIS
    Sunderland, Nicholas
    Kaura, Amit
    Murgatroyd, Francis
    Dhillon, Para
    Scott, Paul
    HEART, 2017, 103 : A40 - A40
  • [7] Late failure of a single-coil transvenous implantable cardioverter-defibrillator lead associated with conductor separation
    Richards, Martyn W.
    Warren, Claire E.
    Anderson, Mark H.
    EUROPACE, 2010, 12 (08): : 1191 - 1192
  • [8] Generator and Lead-Related Complications of Implantable Cardioverter Defibrillators
    Yaminisharif, Ahmad
    Soofizadeh, Nader
    Shafiee, Akbar
    Kazemisaeid, Ali
    Jalali, Arash
    Vasheghani-Farahani, Ali
    INTERNATIONAL CARDIOVASCULAR RESEARCH JOURNAL, 2014, 8 (02) : 66 - 70
  • [9] Dual-coil vs single-coil active pectoral implantable defibrillator lead systems: defibrillation energy requirements and probability of defibrillation success at multiples of the defibrillation energy requirements
    Schulte, B
    Sperzel, J
    Carlsson, J
    Schwarz, T
    Ehrlich, W
    Pitschner, HF
    Neuzner, J
    EUROPACE, 2001, 3 (03): : 177 - 180
  • [10] Comparison of single- and dual-coil active pectoral defibrillation lead systems
    Gold, MR
    Olsovsky, MR
    Pelini, MA
    Peters, RW
    Shorofsky, SR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (06) : 1391 - 1394