Prospective nationwide fluoroscopic and electrical longitudinal follow-up of recalled Riata defibrillator leads in Denmark

被引:9
作者
Larsen, Jacob M. [1 ]
Nielsen, Jens C. [2 ]
Johansen, Jens B. [3 ]
Haarbo, Jens [4 ]
Petersen, Helen H. [5 ]
Thogersen, Anna M. [1 ]
Hjortshoj, Soren P. [1 ]
机构
[1] Aalborg Univ Hosp, Dept Cardiol, Ctr Cardiovasc Res, DK-9000 Aalborg, Denmark
[2] Univ Aarhus, Hosp Skejby, Dept Cardiol, Aarhus, Denmark
[3] Odense Univ Hosp, Dept Cardiol, DK-5000 Odense, Denmark
[4] Copenhagen Univ Hosp, Gentofte Hosp, Dept Cardiol, Copenhagen, Denmark
[5] Copenhagen Univ Hosp, Rigshosp, Dept Cardiol, Copenhagen, Denmark
关键词
Riata; Implantable cardioverter-defibrillator; Defibrillation lead; Lead failure; Recall; Advisory; Fluoroscopy; Lead extraction; SPRINT FIDELIS; EXTERNALIZED CONDUCTORS; PREVALENCE; FAILURE; MULTICENTER; PREDICTORS;
D O I
10.1016/j.hrthm.2014.07.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Recalled St. Jude Medical Riata defibrillator leads are prone to insulation failures with externalized conductors (ECs). Longitudinal studies are needed to guide lead management. OBJECTIVE The purpose of this study was to describe the dynamic nature of EC and the association with electrical abnormalities and lead extraction outcomes. METHODS A nationwide cohort established in 2012 of 295 patients with recalled Riata leads with dwell time 5.1 +/- 1.1 years, 34 ECs, and 19 electrical abnormalities were followed until death, lead discontinuation with fluoroscopy, or a new 2013 screening with fluoroscopy and device interrogation. RESULTS Fluoroscopic follow-up of 239 patients with normal baseline fluoroscopy revealed incident overt EC in 8 leads and borderline EC in 2 leads after 1.1 +/- 0.2 years, with an incidence rate of 3.7 per 100 person-years (95% confidence interval Fluoroscopic follow-up in 27 patients with baseline EC showed an increase in EC length of 4 +/- 1 mm (P < .001) after 1.1 +/- 0.3 years. Electrical follow-up in 276 patients with normal baseline electrical function demonstrated 20 incident electrical abnormalities after 1.0 +/- 0.3 years, with an incidence rate of 7.1 per 100 person-years (95% confidence interval 4.6-11.0). This rate was significantly higher in leads with baseline EC, with an adjusted incidence rate ratio of 4.4 (95% confidence interval 1.7-11.5, P = .002). In 15 extractions, all leads were removed, with 2 major complications. CONCLUSION The development of EC is a dynamic process despite long lead dwell time. ECs are associated with a higher risk of electrical abnormalities. Therefore, lead replacement should be considered, especially in patients with a long life expectancy.
引用
收藏
页码:2141 / 2147
页数:7
相关论文
共 22 条
[1]   Independent multicenter study of Riata and Riata ST implantable cardioverter-defibrillator leads [J].
Abdelhadi, Raed H. ;
Saba, Samir F. ;
Ellis, Christopher R. ;
Mason, Pamela K. ;
Kramer, Daniel B. ;
Friedman, Paul A. ;
Gura, Melanie T. ;
DiMarco, John P. ;
Mugglin, Andrew S. ;
Reynolds, Matthew R. ;
Bazaz, Raveen R. ;
Retel, Linda Kat Linen ;
Hayes, David L. ;
Hauser, Robert G. .
HEART RHYTHM, 2013, 10 (03) :361-365
[2]   Transvenous extraction of implantable cardioverter-defibrillator leads under advisory-A comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leads [J].
Brunner, Michael P. ;
Cronin, Edmond M. ;
Jacob, Jessen ;
Duarte, Valeria E. ;
Tarakji, Khaldoun G. ;
Martin, David O. ;
Callahan, Thomas ;
Borek, P. Peter ;
Cantillon, Daniel J. ;
Niebauer, Mark J. ;
Saliba, Walid I. ;
Kanj, Mohamed ;
Wazni, Oussama ;
Baranowski, Bryan ;
Wilkoff, Bruce L. .
HEART RHYTHM, 2013, 10 (10) :1444-1450
[3]   Mechanisms, predictors, and trends of electrical failure of Riata leads [J].
Cheung, Jim W. ;
Al-Kazaz, Mohamed ;
Thomas, George ;
Liu, Christopher F. ;
Ip, James E. ;
Bender, Seth R. ;
Siddiqi, Faisal K. ;
Markowitz, Steven M. ;
Lerman, Bruce B. .
HEART RHYTHM, 2013, 10 (10) :1453-1459
[4]   Comparison of Sprint Fidelis and Riata defibrillator lead failure rates [J].
Fazal, Iftikhar A. ;
Shepherd, Ewen J. ;
Tynan, Margaret ;
Plummer, Christopher J. ;
McComb, Janet M. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) :848-852
[5]   Riata implantable cardioverter-defibrillator lead failure: Analysis of explanted leads with a unique insulation defect [J].
Hauser, Robert G. ;
McGriff, Deepa ;
Retel, Linda Kallinen .
HEART RHYTHM, 2012, 9 (05) :742-749
[6]   Prevalence of externalized conductors in Riata and Riata ST silicone leads: Results from the prospective, multicenter Riata Lead Evaluation Study [J].
Hayes, David ;
Freedman, Roger ;
Curtis, Anne B. ;
Niebauer, Mark ;
Kay, G. Neal ;
Dinerman, Jay ;
Beau, Scott .
HEART RHYTHM, 2013, 10 (12) :1778-1782
[7]   Fluoroscopic and Electrical Assessment of a Series of Defibrillation Leads: Prevalence of Externalized Conductors [J].
Kodoth, Vivek N. ;
Hodkinson, Emily C. ;
Noad, Rebecca L. ;
Ashfield, Kyle P. ;
Cromie, Nicholas A. ;
McEneaney, David J. ;
Wilson, Carol M. ;
Roberts, Michael J. D. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (12) :1498-1504
[8]   Nationwide Fluoroscopic Screening of Recalled Riata Defibrillator Leads in Denmark [J].
Larsen, Jacob M. ;
Riahi, Sam ;
Nielsen, Jens C. ;
Videbaek, Regitze ;
Haarbo, Jens ;
Due, Karen M. ;
Theuns, Dominic A. M. J. ;
Johansen, Jens B. .
HEART RHYTHM, 2013, 10 (06) :821-827
[9]   Longitudinal Follow-Up of Externalized Riata Leads [J].
Liu, Jeffrey ;
Qin, Dingxin ;
Rattan, Rohit ;
Bazaz, Raveen ;
Adelstein, Evan ;
Jain, Sandeep ;
Saba, Samir .
AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (10) :1616-1618
[10]   Fluoroscopic Screening of Asymptomatic Patients Implanted With the Recalled Riata Lead Family [J].
Liu, Jeffrey ;
Rattan, Rohit ;
Adelstein, Evan ;
Barrington, William ;
Bazaz, Raveen ;
Brode, Susan ;
Jain, Sandeep ;
Mendenhall, G. Stuart ;
Nemec, Jan ;
Razak, Eathar ;
Shalaby, Alaa ;
Schwartzman, David ;
Voigt, Andrew ;
Wang, Norman C. ;
Saba, Samir .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (04) :809-814