Calibration of silicone for passive sampling of semivolatile organic contaminants in indoor air

被引:15
作者
Sedlackova, Lenka [1 ]
Melymuk, Lisa [1 ]
Vrana, Branislav [1 ]
机构
[1] Masaryk Univ, RECETOX, Kamenice 753-5, Brno 62500, Czech Republic
关键词
Sampler calibration; Inhalation exposure; Persistent organic compounds; Model; LOW-DENSITY POLYETHYLENE; PERFORMANCE REFERENCE COMPOUNDS; POLYCHLORINATED-BIPHENYLS; FLAME RETARDANTS; COMPOUNDS SVOCS; DIFFUSION; SAMPLERS; POLYDIMETHYLSILOXANE; EXPOSURE; LDPE;
D O I
10.1016/j.chemosphere.2021.130536
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Semivolatile organic compounds (SVOCs) are mostly man-made chemicals that distribute between the gas and solid phase in the environment. Many of them could pose harm to people and therefore it is important to know their concentrations in the indoor environment to evaluate the related risks. Inhalation exposure can be assessed using passive sampling. In this study, we employed silicone elastomer as a passive sampler for monitoring gaseous polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polybrominated diphenyl ethers (PBDEs) in indoor air. We performed a sampler calibration study in which samplers consisting of 0.5 mm thick silicone sheets with a total surface area of 300 cm(2) were exposed to indoor air in a university lecture theatre for up to 56 days. Uptake kinetics of SVOCs was studied by collecting 2 samplers every week. The results were used to develop a model based on mass transfer theory that can be used to estimate the air sampling rate R-S as a function of compound's molecular volume. We examined release kinetics of performance reference compounds that covered a broad range of silicone-air partition coefficient (log K-SA 5.95-9.49) and investigated a hypothesis of isotropic exchange kinetics, i.e. equality of rate constants for uptake and release, of SVOCs. PCBs and OCPs concentration in air calculated from contaminant amounts accumulated in passive samplers were in good agreement with those determined by active sampling running simultaneously during the entire study. The use of performance reference compounds is suitable for in situ passive sampler calibration. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 44 条
[11]  
Cussler E.L., 2009, Diffusion mass transfer in fluid systems: Mass transfer in fluid systems, P237, DOI DOI 10.1017/CBO9780511805134.010
[12]  
Fiedler H, 2003, HANDB ENVIRON CHEM, V3, P123
[13]   DIFFUSION ON SURFACES .1. EFFECT OF CONCENTRATION ON DIFFUSIVITY OF PHYSICALLY ADSORBED GASES [J].
GILLILAND, ER ;
BADDOUR, RF ;
PERKINSON, GP ;
SLADEK, KJ .
INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1974, 13 (02) :95-100
[14]   Measuring Personal Exposure to Organophosphate Flame Retardants Using Silicone Wristbands and Hand Wipes [J].
Hammel, Stephanie C. ;
Hoffman, Kate ;
Webster, Thomas F. ;
Anderson, Kim A. ;
Stapleton, Heather M. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2016, 50 (08) :4483-4491
[15]   Calibration and application of PUF disk passive air samplers for tracking polycyclic aromatic compounds (PACs) [J].
Harner, Tom ;
Su, Ky ;
Genualdi, Susie ;
Karpowicz, Jessica ;
Ahrens, Lutz ;
Mihele, Cristian ;
Schuster, Jasmin ;
Charland, Jean-Pierre ;
Narayan, Julie .
ATMOSPHERIC ENVIRONMENT, 2013, 75 :123-128
[16]   Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices [J].
Huckins, JN ;
Petty, JD ;
Lebo, JA ;
Almeida, FV ;
Booij, K ;
Alvarez, DA ;
Clark, RC ;
Mogensen, BB .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (01) :85-91
[17]   Field calibration of low density polyethylene passive samplers for gaseous POPs [J].
Khairy, Mohammed A. ;
Lohmann, Rainer .
ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2014, 16 (03) :414-421
[18]   Associations of organochlorine pesticides and polychlorinated biphenyls with total, cardiovascular, and cancer mortality in elders with differing fat mass [J].
Kim, Se-A ;
Kim, Ki-Su ;
Lee, Yu-Mi ;
Jacobs, David R. ;
Lee, Duk-Hee .
ENVIRONMENTAL RESEARCH, 2015, 138 :1-7
[19]   Health consequences of exposure to brominated flame retardants: A systematic review [J].
Kim, Young Ran ;
Harden, Fiona A. ;
Toms, Leisa-Maree L. ;
Norman, Rosana E. .
CHEMOSPHERE, 2014, 106 :1-19
[20]   The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutants [J].
Klepeis, NE ;
Nelson, WC ;
Ott, WR ;
Robinson, JP ;
Tsang, AM ;
Switzer, P ;
Behar, JV ;
Hern, SC ;
Engelmann, WH .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2001, 11 (03) :231-252