Calibration of silicone for passive sampling of semivolatile organic contaminants in indoor air

被引:15
作者
Sedlackova, Lenka [1 ]
Melymuk, Lisa [1 ]
Vrana, Branislav [1 ]
机构
[1] Masaryk Univ, RECETOX, Kamenice 753-5, Brno 62500, Czech Republic
关键词
Sampler calibration; Inhalation exposure; Persistent organic compounds; Model; LOW-DENSITY POLYETHYLENE; PERFORMANCE REFERENCE COMPOUNDS; POLYCHLORINATED-BIPHENYLS; FLAME RETARDANTS; COMPOUNDS SVOCS; DIFFUSION; SAMPLERS; POLYDIMETHYLSILOXANE; EXPOSURE; LDPE;
D O I
10.1016/j.chemosphere.2021.130536
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Semivolatile organic compounds (SVOCs) are mostly man-made chemicals that distribute between the gas and solid phase in the environment. Many of them could pose harm to people and therefore it is important to know their concentrations in the indoor environment to evaluate the related risks. Inhalation exposure can be assessed using passive sampling. In this study, we employed silicone elastomer as a passive sampler for monitoring gaseous polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polybrominated diphenyl ethers (PBDEs) in indoor air. We performed a sampler calibration study in which samplers consisting of 0.5 mm thick silicone sheets with a total surface area of 300 cm(2) were exposed to indoor air in a university lecture theatre for up to 56 days. Uptake kinetics of SVOCs was studied by collecting 2 samplers every week. The results were used to develop a model based on mass transfer theory that can be used to estimate the air sampling rate R-S as a function of compound's molecular volume. We examined release kinetics of performance reference compounds that covered a broad range of silicone-air partition coefficient (log K-SA 5.95-9.49) and investigated a hypothesis of isotropic exchange kinetics, i.e. equality of rate constants for uptake and release, of SVOCs. PCBs and OCPs concentration in air calculated from contaminant amounts accumulated in passive samplers were in good agreement with those determined by active sampling running simultaneously during the entire study. The use of performance reference compounds is suitable for in situ passive sampler calibration. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 44 条
[1]   DIFFUSION OF SATURATED-HYDROCARBONS IN LOW-DENSITY POLYETHYLENE (LDPE) FILMS [J].
ASFOUR, AFA ;
SALEEM, M ;
DEKEE, D ;
HARRISON, BH .
JOURNAL OF APPLIED POLYMER SCIENCE, 1989, 38 (08) :1503-1514
[2]  
ATSDR, 2019, Toxicological profile for DDT, DDE, and DDD, P1
[3]   Passive air sampling theory for semivolatile organic compounds [J].
Bartkow, ME ;
Booij, K ;
Kennedy, KE ;
Müller, JF ;
Hawker, DW .
CHEMOSPHERE, 2005, 60 (02) :170-176
[4]   Evaluation of performance reference compounds in polyethylene-based passive air samplers [J].
Bartkow, Michael E. ;
Jones, Kevin C. ;
Kennedy, Karen E. ;
Holling, Neil ;
Hawker, Darryl W. ;
Mueller, Jochen F. .
ENVIRONMENTAL POLLUTION, 2006, 144 (02) :365-370
[5]   Observations on persistent organic pollutants in indoor and outdoor air using passive polyurethane foam samplers [J].
Bohlin, Pernilla ;
Jones, Kevin C. ;
Tovalin, Horacio ;
Strandberg, Bo .
ATMOSPHERIC ENVIRONMENT, 2008, 42 (31) :7234-7241
[6]  
Bohlin P, 2014, ENVIRON SCI-PROC IMP, V16, P2617, DOI [10.1039/c4em00305e, 10.1039/C4EM00305E]
[7]   Spiking of performance reference compounds in low density polyethylene and silicone passive water samplers [J].
Booij, K ;
Smedes, F ;
van Weerlee, EM .
CHEMOSPHERE, 2002, 46 (08) :1157-1161
[8]  
Booij K, 2007, COMP ANAL C, V48, P141, DOI 10.1016/S0166-526X(06)48007-7
[9]   An Improved Method for Estimating in Situ Sampling Rates of Nonpolar Passive Samplers [J].
Booij, Kees ;
Smedes, Foppe .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (17) :6789-6794
[10]  
Cheminformatics molinspiration, MOLINSPIRATION