Impact of DC Bias on the Magnetic Loading of Three Phase Three Limb Transformer Based on Finite Element Method

被引:1
作者
Kohli, Saurabh [1 ]
Mahajan, S. B. [1 ]
Sanjeevikumar, Padmanaban [2 ]
Fedak, Viliam [3 ]
Oleschuk, Valentin [4 ]
机构
[1] Marathwada Inst Technol, Dept Elect & Elect Engn, Aurangabad, Maharashtra, India
[2] Univ Johannesburg, Dept Elect & Elect Engn, Johannesburg, South Africa
[3] Tech Univ Kosice, Dept Elect Engn & Mechatron, Kosice, Slovakia
[4] Moldavian Acad Sci, Inst Power Engn, Kishinev 2028, MD, Moldova
来源
ADVANCES IN POWER SYSTEMS AND ENERGY MANAGEMENT | 2018年 / 436卷
关键词
Three phase transformer model; DC bias; Half cycle saturation; Harmonics; Magnetizing currents; Geo-magnetically induced currents; SATURATION; HARMONICS; FEM;
D O I
10.1007/978-981-10-4394-9_10
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article proposes a modelling mechanism based on Finite Element Method (FEM) to understand the impact of DC currents on the magnetic loading of the transformer. It details on the way magnetizing currents vary and harmonics develop in a transformer. The analysis is performed using ANSYS tool for generating the scaled transformer model and MATLAB for plotting the results. The analysis shows that on varying the primary voltage to different levels of voltages and injecting DC currents based on a weakly coupled multi harmonic approach the three phase three limb transformer is subjected to varying magnetizing currents with the development of odd harmonics based on the saturation level of transformer. The even harmonics are not observed owning to the structure of three phase three limb transformer which offers a high reluctance to DC flux. Furthermore the scaled transformer is observed in ANSYS and it is visualized that the stray fluxes and the saturation levels of the three limb transformer raises to a higher level on impact of DC currents of varying magnitudes.
引用
收藏
页数:10
相关论文
共 13 条
[1]  
Bjorn R, 2015, ARCHIEVE ELECT ENG, V64, P129
[2]  
Bjorn R., 2013, INT J COMPUT MATH EL, V32
[3]   Modeling and simulation, and their validation of three-phase transformers with three legs under DC bias [J].
Fuchs, EF ;
You, Y ;
Roesler, DJ .
IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (02) :443-449
[4]  
Girgis R., 2012, PES T D 2012, P1, DOI [10.1109/TDC.2012.6281595, DOI 10.1109/TDC.2012.6281595]
[5]  
KAPPENMAN JG, 1996, IEEE POWER ENG REV
[6]   HARMONICS GENERATED FROM A DC BIASED TRANSFORMER [J].
LU, S ;
LIU, YL ;
DELAREE, J .
IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (02) :725-731
[7]   FEM ANALYSIS OF DC SATURATION TO ASSESS TRANSFORMER SUSCEPTIBILITY TO GEOMAGNETICALLY INDUCED CURRENTS [J].
LU, S ;
LIU, YL ;
WALLING, RA ;
CHEN, X .
IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) :1367-1376
[8]  
Ngnegueu T., 2012, BEHAV TRANSFORMERS D
[9]   Geomagnetically induced current effects on transformer's [J].
Price, PR .
IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (04) :1002-1008
[10]  
Vassell G. S, 1991, IEEE POWER ENG REV