A flow injection sampling resonance light scattering system for total protein determination in human serum

被引:18
作者
Dong, Lijun [1 ]
Li, Ying [1 ]
Zhang, Yaheng [1 ]
Chen, Xingguo [1 ]
Hu, Zhide [1 ]
机构
[1] Lanzhou Univ, Dept Chem, Lanzhou 730000, Peoples R China
关键词
flow injection resonance light scattering; Methyl Blue; proteins;
D O I
10.1016/j.saa.2006.06.020
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A novel flow injection method with resonance light scattering detection was developed for the determination of total protein concentrations. This method is based on the enhancement of RLS signals from Methyl Blue (MB) by protein. The enhanced RLS intensities at 333 nm, in a pH 4.1 acidic aqueous solution, were proportional to the protein concentration over the range 2.0-37.3 and 1.0-36.0 mu g ml(-1) for human serum albumin (HSA) and bovine serum albumin (BSA), respectively. The corresponding limits of detection (3(T) of 45 ng ml(-1) for HSA and 80 ng ml(-1) for BSA were attained. The method was successfully applied to the quantification of total proteins in human serum samples, the maximum relative error is less than 1% and the recovery is between 98% and 102%. The sample throughput was 60 h(-1). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1317 / 1322
页数:6
相关论文
共 35 条
[1]   Detection of fast capillary electrophoresis peptide and protein separations using electrospray ionization with a time-of-flight mass spectrometer [J].
Banks, JF ;
Dresch, T .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1480-1485
[2]   High-sensitivity detection of DNA hybridization on microarrays using resonance light scattering [J].
Bao, P ;
Frutos, AG ;
Greef, C ;
Lahiri, J ;
Muller, U ;
Peterson, TC ;
Warden, L ;
Xie, XY .
ANALYTICAL CHEMISTRY, 2002, 74 (08) :1792-1797
[3]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[4]   Determination of protein content using a solid phase spectrophotometric procedure [J].
Capitán-Vallvey, LF ;
Duque, O ;
Mirón-García, G ;
Checa-Moreno, R .
ANALYTICA CHIMICA ACTA, 2001, 433 (01) :155-163
[5]   A simple and sensitive assay of nucleic acids based on the enhanced resonance light scattering of zwitterionics [J].
Chen, ZG ;
Ding, WF ;
Ren, FL ;
Liu, JB ;
Liang, YZ .
ANALYTICA CHIMICA ACTA, 2005, 550 (1-2) :204-209
[6]   Improved o-sulfophenylfluorone-titanium(IV) complex method for total urinary protein assay [J].
Fujita, Y ;
Mori, I ;
Matsuo, T .
ANALYTICAL SCIENCES, 1997, 13 (03) :513-516
[7]   A highly sensitive assay for protein using resonance light-scattering technique with dibromohydroxyphenylfluorone-molybdenum(VI) complex [J].
Guo, ZX ;
Shen, HX .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1999, 55 (14) :2919-2925
[8]   Determination of proteins with α,β,γ,δ-tetrakis(4-sulfophenyl)porphine by measuring the enhanced resonance light scattering at the air/liquid interface [J].
Huang, CZ ;
Li, YF ;
Feng, P .
ANALYTICA CHIMICA ACTA, 2001, 443 (01) :73-80
[9]   Interactions of Janus Green B with double stranded DNA and the determination of DNA based on the measurement of enhanced resonance light scattering [J].
Huang, CZ ;
Li, YF ;
Huang, XH ;
Li, M .
ANALYST, 2000, 125 (07) :1267-1272
[10]   Resonance light scattering imaging detection of proteins with α, β, γ, δ-tetrakis(p-sulfophenyl)porphyrin [J].
Huang, CZ ;
Liu, Y ;
Wang, YH ;
Guo, HP .
ANALYTICAL BIOCHEMISTRY, 2003, 321 (02) :236-243