A Fault-Component based Adaptive Distance Protection Scheme

被引:0
|
作者
Lin, Xiangning [1 ]
Weng, Hanli [2 ]
Wang, Bin [1 ]
Bo, Zhiqian [3 ]
机构
[1] Three Gorges Univ, Coll Elect Engn & Informat Technol, Yichang 443002, Hubei Province, Peoples R China
[2] Huazhong Univ Sci & Technol, Elect Power Secur & High Efficiency Lab, Wuhan 430074, Peoples R China
[3] AREVA T&D Automat & Informat Syst, Stafford ST17 4LX, England
关键词
Transmission Line; Self-adaptive; Fault-component based; Distance Protection; Power Swing;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Utilizing information of the wide area phasor measurement units (PMU), a novel self-adaptive fault-component based distance protection scheme is proposed. It aims at removing the defects of the conventional fault-component based distance relay. This scheme can adjust the operation threshold dynamically, depending on the real-time parameter measurement of two equivalent power systems. The limitations of the conventional solutions are analyzed in the beginning. Then, the boundary conditions of mal-operation of previous criteria are deduced in theory. Further, a new criterion combining self-adaptive threshold with criterion switching is proposed. The effectiveness of the new criterion is verified with the result of ATP simulations.
引用
收藏
页码:1146 / +
页数:3
相关论文
共 50 条
  • [41] Adaptive directional current protection scheme based on steady state component in distribution network with DG
    Ma J.
    Liu J.
    2018, Electric Power Automation Equipment Press (38): : 1 - 9
  • [42] A Novel Distance Protection Scheme for Island Grid Based on Control Combined With Protection Under Single-phase Ground Fault
    Li Z.
    Wu Y.
    Zheng Y.
    Xiao S.
    Wei F.
    Li Z.
    Lin X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (24): : 9509 - 9522
  • [43] APPLICATION OF ADAPTIVE KALMAN FILTERING IN FAULT CLASSIFICATION, DISTANCE PROTECTION, AND FAULT LOCATION USING MICROPROCESSORS
    GIRGIS, AA
    MAKRAM, EB
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1988, 3 (01) : 301 - 309
  • [44] The Implementation Scheme of Distance Protection Based on Parameter Identification
    Cheng, Qiutao
    Yun, Baoji
    2014 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C 2014), 2014, : 646 - 649
  • [45] Adaptive distance protection of double-circuit lines based on differential equation fault loop model
    Bozek, Marcin
    Izykowski, Jan
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 150 - 154
  • [46] Analysis of Unsymmetrical fault using Symmetrical component for Improvement of Overcurrent Protection Scheme
    Mrugsarita
    Borkar, D.
    Kawita
    Thakur, D.
    2013 INTERNATIONAL CONFERENCE ON COMPUTER COMMUNICATION AND INFORMATICS, 2013,
  • [47] Application of a Recursive Phasor Estimation Method for Adaptive Fault Component Based Differential Protection of Power Transformers
    Ashrafian, Abdolaziz
    Mirsalim, Mojtaba
    Masoum, Mohammad A. S.
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2017, 13 (03) : 1381 - 1392
  • [48] Fault classification for distance protection
    Akke, M
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 835 - 839
  • [49] Adaptive 100% Stator Ground Fault Protection Based on Third-Harmonic Differential Voltage Scheme
    Safari-Shad, Nader
    Franklin, Russ
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (04) : 1429 - 1436
  • [50] Transmission line adaptive protection scheme: A new fault detection approach based on pilot superimposed impedance
    Khoshbouy, Morteza
    Yazdaninejadi, Amin
    Bolandi, Tohid Ghanizadeh
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 137