Development of a fast Monte Carlo dose calculation system for online adaptive radiation therapy quality assurance

被引:20
|
作者
Wang, Yuhe [1 ]
Mazur, Thomas R. [1 ]
Park, Justin C. [1 ]
Yang, Deshan [1 ]
Mutic, Sasa [1 ]
Li, H. Harold [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
关键词
GPU; Monte Carlo; variance reduction; MRI guided radiation therapy; adaptive radiation therapy; RADIOTHERAPY; PHOTON; GEANT4; IMPLEMENTATION; SIMULATION; TRANSPORT; EGSNRC; CODE;
D O I
10.1088/1361-6560/aa6e38
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Online adaptive radiation therapy (ART) based on real-time magnetic resonance imaging represents a paradigm-changing treatment scheme. However, conventional quality assurance (QA) methods based on phantom measurements are not feasible with the patient on the treatment couch. The purpose of this work is to develop a fast Monte Carlo system for validating online re-optimized tri-Co-60 IMRT adaptive plans with both high accuracy and speed. The Monte Carlo system is based on dose planning method (DPM) code with further simplification of electron transport and consideration of external magnetic fields. A vendor-provided head model was incorporated into the code. Both GPU acceleration and variance reduction were implemented. Additionally, to facilitate real-time decision support, a C++ GUI was developed for visualizing 3D dose distributions and performing various analyses in an online adaptive setting. A thoroughly validated Monte Carlo code (gPENELOPE) was used to benchmark the new system, named GPU-accelerated DPM with variance reduction (gDPMvr). The comparison using 15 clinical IMRT plans demonstrated that gDPMvr typically runs 43 times faster with only 0.5% loss in accuracy. Moreover, gDPMvr reached 1% local dose uncertainty within 2.3 min on average, and thus is well-suited for ART QA.
引用
收藏
页码:4970 / 4990
页数:21
相关论文
共 50 条
  • [41] Dosimetric verification and clinical evaluation of a new commercially available Monte Carlo-based dose algorithm for application in stereotactic body radiation therapy (SBRT) treatment planning
    Fragoso, Margarida
    Wen, Ning
    Kumar, Sanath
    Liu, Dezhi
    Ryu, Samuel
    Movsas, Benjamin
    Munther, Ajlouni
    Chetty, Indrin J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16) : 4445 - 4464
  • [42] Characterization and evaluation of an integrated quality monitoring system for online quality assurance of external beam radiation therapy
    Hoffman, David
    Chung, Eunah
    Hess, Clayton
    Stern, Robin
    Benedict, Stanley
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (01): : 40 - 48
  • [43] A Monte Carlo dose calculation system for ophthalmic brachytherapy based on a realistic eye model
    Miras del Rio, Hector
    Ortiz Lora, Antonio
    Bertolet Reina, Alejandro
    Terron Leon, Jose Antonio
    MEDICAL PHYSICS, 2021, 48 (08) : 4542 - 4559
  • [44] The development of patient-specific quality assurance (PSQA) for a proton wobbling nozzle using PTSim Monte Carlo code
    Oanh, Luu Dang Hoang
    Aso, Tsukasa
    Wang, Chun-Chieh
    Chao, Tsi-Chian
    Cho, I-Chun
    RADIATION PHYSICS AND CHEMISTRY, 2024, 223
  • [45] Quality assurance for on-table adaptive magnetic resonance guided radiation therapy: A software tool to complement secondary dose calculation and failure modes discovered in clinical routine
    Rippke, Carolin
    Schrenk, Oliver
    Renkamp, C. Katharina
    Buchele, Carolin
    Hoerner-Rieber, Juliane
    Debus, Juergen
    Alber, Markus
    Klueter, Sebastian
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (03):
  • [46] Deep learning-based fast denoising of Monte Carlo dose calculation in carbon ion radiotherapy
    Zhang, Xinyang
    Zhang, Hui
    Wang, Jian
    Ma, Yuanyuan
    Liu, Xinguo
    Dai, Zhongying
    He, Rui
    He, Pengbo
    Li, Qiang
    MEDICAL PHYSICS, 2023, 50 (12) : 7314 - 7323
  • [47] NRG Oncology Survey of Monte Carlo Dose Calculation Use in US Proton Therapy Centers
    Lin, Liyong
    Taylor, Paige A.
    Shen, Jiajian
    Saini, Jatinder
    Kang, Minglei
    Simone, Charles B.
    Bradley, Jeffrey D.
    Li, Zuofeng
    Xiao, Ying
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2021, 8 (02) : 73 - 81
  • [48] Validation and application of a fast Monte Carlo algorithm for assessing the clinical impact of approximations in analytical dose calculations for pencil beam scanning proton therapy
    Huang, Sheng
    Souris, Kevin
    Li, Siyang
    Kang, Minglei
    Montero, Ana Maria Barragan
    Janssens, Guillaume
    Lin, Alexander
    Garver, Elizabeth
    Ainsley, Christopher
    Taylor, Paige
    Xiao, Ying
    Lin, Liyong
    MEDICAL PHYSICS, 2018, 45 (12) : 5631 - 5642
  • [49] Dose calculation differences between Monte Carlo and pencil beam depend on the tumor locations and volumes for lung stereotactic body radiation therapy
    Zhuang, Tingliang
    Djemil, Toufik
    Qi, Peng
    Magnelli, Anthony
    Stephans, Kevin
    Videtic, Gregory
    Xia, Ping
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (02): : 38 - 51
  • [50] Development of accurate dose evaluation technique of X-ray inspection for quality assurance of semiconductor with Monte Carlo simulation
    Park, Hyojun
    Choi, Hyun Joon
    Rhew, Keunho
    Lim, Heonsang
    Lee, Hyunyoung
    Jang, Iloh
    Min, Chul Hee
    APPLIED RADIATION AND ISOTOPES, 2019, 154