Assessment of Virtual Monoenergetic Images in Run-off Computed Tomography Angiography: A Comparison Study to Conventional Images From Spectral Detector Computed Tomography

被引:6
作者
Ren, Haiyan [1 ]
Zhen, Yanhua [1 ]
Gong, Zheng [1 ]
Wang, Chuanzhuo [1 ]
Chang, Zhihui [1 ]
Zheng, Jiahe [1 ]
机构
[1] China Med Univ, Shengjing Hosp, Dept Radiol, Shenyang, Peoples R China
关键词
spectral detector CT; virtual monoenergetic images; angiography;
D O I
10.1097/RCT.0000000000001126
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aims of this study were to evaluate image quality of virtual monoenergetic images (VMIs) compared with conventional images (CIs) from spectral detector CT (SDCT) and to explore the optimal energy level in run-off computed tomography angiography (CTA). Methods The data sets of 35 patients who received run-off CTA on the SDCT were collected in this retrospective study. Conventional images were generated via iterative reconstruction algorithm and VMI series from 40 to 120 keV were generated via spectral reconstruction algorithm. The objective indices including vascular attenuation, noise, signal-to-noise ratio, and contrast-to-noise ratio were compared. Two readers performed subjective evaluation using a 5-point scale. Results The attenuation showed higher values compared with CIs at 40 to 60 keV (P < 0.001). The noise was similar in 60- to 80-keV VMIs and significantly decreased in 90- to 120-keV VMIs (P < 0.001) in comparison with CIs. The signal-to-noise ratio and contrast-to-noise ratio were improved in 40- to 60-keV VMIs compared with CIs (P < 0.05). The score of subjective assessment was higher than that of CIs in 50- to 70-keV VMIs (P < 0.001). Conclusions Virtual monoenergetic images can provide improved image quality compared with CIs from SDCT in run-off CTA, and VMIs at 60 keV may be the best choice in evaluating lower extremity arteries.
引用
收藏
页码:232 / 237
页数:6
相关论文
共 23 条
  • [1] Dual Energy CT Angiography of Peripheral Arterial Disease: Feasibility of Using Lower Contrast Medium Volume
    Almutairi, Abdulrahman
    Sun, Zhonghua
    Poovathumkadavi, Abduljaleel
    Assar, Tarek
    [J]. PLOS ONE, 2015, 10 (09):
  • [2] Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT
    Ananthakrishnan, Lakshmi
    Rajiah, Prabhakar
    Ahn, Richard
    Rassouli, Negin
    Xi, Yin
    Soesbe, Todd C.
    Lewis, Matthew A.
    Lenkinski, Robert E.
    Leyendecker, John R.
    Abbara, Suhny
    [J]. ABDOMINAL RADIOLOGY, 2017, 42 (03) : 702 - 709
  • [3] Intra-individual comparison between abdominal virtual mono-energetic spectral and conventional images using a novel spectral detector CT
    Doerner, Jonas
    Wybranski, Christian
    Byrtus, Jonathan
    Houbois, Christian
    Hauger, Myriam
    Heneweer, Carola
    Siedek, Florian
    Hickethier, Tilman
    Hokamp, Nils Grosse
    Maintz, David
    Haneder, Stefan
    [J]. PLOS ONE, 2017, 12 (08):
  • [4] Diagnostic Efficiency of Low-Dose CT Angiography Compared With Conventional Angiography in Peripheral Arterial Occlusions
    Duan, Yanhua
    Wang, Ximing
    Yang, Xiancun
    Wu, Dawei
    Cheng, Zhaoping
    Wu, Lebin
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (06) : W906 - W914
  • [5] Dual-Energy CT: New Horizon in Medical Imaging
    Goo, Hyun Woo
    Goo, Jin Mo
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (04) : 555 - 569
  • [6] Monoenergetic reconstructions for imaging of coronary artery stents using spectral detector CT: In-vitro experience and comparison to conventional images
    Hickethier, Tilman
    Baessler, Bettina
    Kroeger, Jan Robert
    Doerner, Jonas
    Pahn, Gregor
    Maintz, David
    Michels, Guido
    Bunck, Alexander C.
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2017, 11 (01) : 33 - 39
  • [7] Virtual monoenergetic images from spectral detector CT as a surrogate for conventional CT images: Unaltered attenuation characteristics with reduced image noise
    Hokamp, Nils Grosse
    Gilkeson, R.
    Jordan, M. K.
    Laukamp, K. R.
    Neuhaus, Victor-Frederick
    Haneder, S.
    Halliburton, S. S.
    Gupta, A.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2019, 117 : 49 - 55
  • [8] Noise characteristics of virtual monoenergetic images from a novel detector-based spectral CT scanner
    Kalisz, Kevin
    Rassouli, Negin
    Dhanantwari, Amar
    Jordan, David
    Rajiah, Prabhakar
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 98 : 118 - 125
  • [9] Measurement of observer agreement
    Kundel, HL
    Polansky, M
    [J]. RADIOLOGY, 2003, 228 (02) : 303 - 308
  • [10] Lower extremity CT angiography at 80 kVp using iterative model reconstruction
    Liu, B.
    Gao, S.
    Chang, Z.
    Wang, C.
    Liu, Z.
    Zheng, J.
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2018, 99 (09) : 561 - 568