The use of pure materials in chemical analysis is currently in high demand due to the need to provide reliable measurement results. In the Electrochemistry Laboratory of the National Institute of Metrology from Brazil (Inmetro) is located the primary system of coulometry, which is considered the standard of the measurement for the amount of substance. The main function of this primary system is to certify primary reference materials to ensure reliability and metrological traceability for titration analyses. Some important certified reference materials (CRMs), homogeneous, stable, and characterized with an accurate property value have been developed. This work aims to present the stages for certifying the primary reference materials in a metrological approach: potassium hydrogen phthalate for acid-base titration, potassium chloride for precipitation titration, and potassium dichromate for redox titration. In addition, the key comparisons that were necessary to demonstrate the national traceability structure's equivalence for these CRMs' international recognition will be shown.
引用
收藏
页码:1411 / 1420
页数:10
相关论文
共 13 条
  • [1] Metrological evaluation of the certification of primary reference materials characterized by high-precision constant-current coulometry for the reliability of the titration analyses
    Paulo Paschoal Borges
    Wiler Batista da Silva
    Journal of Applied Electrochemistry, 2014, 44 : 1411 - 1420
  • [2] HIGH-PRECISION ANALYSIS OF NUCLEAR MATERIALS BY CONSTANT-CURRENT COULOMETRY
    GOODE, GC
    HERRINGT.J
    JONES, WT
    ANALYTICA CHIMICA ACTA, 1967, 37 (04) : 445 - &
  • [3] A CELL FOR HIGH-PRECISION CONSTANT-CURRENT COULOMETRY WITH EXTERNAL GENERATION OF TITRANT
    KNOECK, J
    DIEHL, H
    TALANTA, 1969, 16 (05) : 567 - &
  • [4] INEXPENSIVE HIGH-PRECISION CONSTANT-CURRENT SYSTEM WITH METERING ELECTRONICS
    VANCE, DL
    WATSON, DE
    IEEE TRANSACTIONS ON GEOSCIENCE ELECTRONICS, 1971, GE 9 (01): : 72 - &
  • [5] HIGH-PRECISION ANALYSIS OF NUCLEAR MATERIALS BY CONSTANT-CURRENT COULOMETR .2. DETERMINATION OF THORIUM
    GOODE, GC
    JONES, WT
    ANALYTICA CHIMICA ACTA, 1967, 38 (03) : 363 - &
  • [6] A High-precision Constant Current Primary Side Controller with Inductance Compensation
    Xu, Yang
    Chang, Changyuan
    Bian, Bin
    Chen, Yao
    Hu, Junjie
    2015 IEEE INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2015,
  • [7] High-precision Constant Current Controller for Primary-side Feedback LED Drivers
    Wang, Yulin
    Jiang, Junmin
    He, Lenian
    2013 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2013,
  • [8] Primary-Side Peak Current Measurement Strategy for High-Precision Constant Output Current Control
    Wu, Cheng-Nan
    Chen, Yang-Lin
    Chen, Yaow-Ming
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (02) : 967 - 975
  • [9] High-Precision Constant Output Current Control for Primary-Side Regulated Flyback Converters
    Wu, Cheng-Nan
    Chen, Yaow-Ming
    Chen, Yang-Lin
    2013 TWENTY-EIGHTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2013), 2013, : 3092 - 3095
  • [10] High-Precision Digital Constant Current Controller with Demagnetization-Time Compensation for Primary-Side Regulation Flyback Converter
    Chang, Changyuan
    Huang, Xiaomin
    Li, Yuanye
    Chen, Yao
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2016, 25 (08)