An Inductance Voltage Vector Control Strategy and Stability Study Based on Proportional Resonant Regulators under the Stationary αβ Frame for PWM Converters

被引:1
作者
Sun, Qiang [1 ]
Wei, Kexin [4 ]
Gao, Chenghai [1 ]
Wang, Shasha [3 ]
Liang, Bin [2 ]
机构
[1] Tianjin Univ, Sch Elect Engn & Automat, Tianjin 300072, Peoples R China
[2] Tianjin Univ Technol, Tianjin Key Lab Control Theory & Applicat Complic, Tianjin, Peoples R China
[3] Tianjin EV Energies Co Ltd, Dept Res & Dev, Tianjin, Peoples R China
[4] Tianjin Univ Technol, Sch Elect Engn, Tianjin, Peoples R China
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金;
关键词
Active damping; Inductance voltage vector; Pole-zero matching; Proportional resonant regulator; Stability; DIRECT POWER-CONTROL; GRID-CONNECTED INVERTERS; LCL FILTERS; DESIGN; MODULATION; OPTIMIZATION;
D O I
10.6113/JPE.2016.16.3.1110
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The mathematical model of a three phase PWM converter under the stationary alpha beta reference frame is deduced and constructed based on a Proportional-Resonant (PR) regulator, which can replace trigonometric function calculation, Park transformation, real-time detection of a Phase Locked Loop and feed-forward decoupling with the proposed accurate calculation of the inductance voltage vector. To avoid the parallel resonance of the LCL topology, the active damping method of the proportional capacitor-current feedback is employed. As to current vector error elimination, an optimized PR controller of the inner current loop is proposed with the zero-pole matching (ZPM) and cancellation method to configure the regulator. The impacts on system's characteristics and stability margin caused by the PR controller and control parameter variations in the inner-current loop are analyzed, and the correlations among active damping feedback coefficient, sampling and transport delay, and system robustness have been established. An equivalent model of the inner current loop is studied via the pole-zero locus along with the pole placement method and frequency response characteristics. Then, the parameter values of the control system are chosen according to their decisive roles and performance indicators. Finally, simulation and experimental results obtained while adopting the proposed method illustrated its feasibility and effectiveness, and the inner current loop achieved zero static error tracking with a good dynamic response and steady-state performance.
引用
收藏
页码:1110 / 1121
页数:12
相关论文
共 33 条
[1]   Control of Grid-Connected Inverters Using Adaptive Repetitive and Proportional Resonant Schemes [J].
Abusara, Mohammad A. ;
Sharkh, Suleiman M. ;
Zanchetta, Pericle .
JOURNAL OF POWER ELECTRONICS, 2015, 15 (02) :518-529
[2]   Table-Based Direct Power Control: A Critical Review for Microgrid Applications [J].
Alonso-Martinez, Jaime ;
Eloy-Garcia Carrasco, Joaquin ;
Arnaltes, Santiago .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (12) :2949-2961
[3]   Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping [J].
Bao, Chenlei ;
Ruan, Xinbo ;
Wang, Xuehua ;
Li, Weiwei ;
Pan, Donghua ;
Weng, Kailei .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1239-1253
[4]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[5]   Predictive Direct Power Control of Three-Phase Pulsewidth Modulation (PWM) Rectifier Using Space-Vector Modulation (SVM) [J].
Bouafia, Abdelouahab ;
Gaubert, Jean-Paul ;
Krim, Fateh .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (01) :228-236
[6]  
BOUAZIZ B, 2015, INT J ELECT ENG INFO, V7, P42
[7]   Filter-Based Active Damping of Voltage Source Converters With LCL Filter [J].
Dannehl, Joerg ;
Liserre, Marco ;
Fuchs, Friedrich Wilhelm .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (08) :3623-3633
[8]   Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters [J].
Dannehl, Joerg ;
Fuchs, Friedrich Wilhelm ;
Hansen, Steffan ;
Thogersen, Paul Bach .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (04) :1509-1517
[9]   Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With LCL Filters [J].
Dannehl, Joerg ;
Wessels, Christian ;
Fuchs, Friedrich Wilhelm .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (02) :380-388
[10]   Passivity-Based Controller Design of Grid-Connected VSCs for Prevention of Electrical Resonance Instability [J].
Harnefors, Lennart ;
Yepes, Alejandro G. ;
Vidal, Ana ;
Doval-Gandoy, Jesus .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (02) :702-710