A paper platform for colorimetric determination of aluminum Chink fer hydrochloride in antiperspirant samples

被引:8
作者
Polli Silvestre, Amanda Leticia [1 ]
Milani, Maria Izabel [1 ]
Rossini, Eduardo Luiz [1 ]
Pezza, Leonardo [1 ]
Pezza, Helena Redigolo [1 ]
机构
[1] Univ Estadual Paulista, Inst Quim, R Prof Francisco Degni 55,POB 355, BR-14800900 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Diffuse reflectance; Aluminum; Paper platform; Antiperspirant; SPOT TEST/DIFFUSE REFLECTANCE; DEODORANTS; HYDROXIDE; RISK;
D O I
10.1016/j.saa.2018.06.049
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A simple, fast, low-cost, portable, and eco-friendly method using a spot test on a paper platform, together with diffuse reflectance spectroscopy, was developed and validated for the quantification of aluminum hydrochloride, a potential neurotoxic agent, in antiperspirant samples. The determination of aluminum hydrochloride was performed at a wavelength of 615 nm, by measuring consumption of the purple colorimetric reagent Alizarin S, due to reaction with aluminum. The linear range was from 10.0 to 125.0 mg L-1 and could be described by the equation: A(R) = 0.4479-0.002543 C-AI (R = 0.999). The limits of detection (LOD) and quantification (LOQ) were 3.06 and 10.2 mg L-1 respectively. The method was specific, accurate, and repeatable, with relative standard deviation (RSD) <5.0%. The recovery was between 92.2 and 103.4%. The method was successfully used for the determination of aluminum hydrochloride in commercial antiperspirant samples, revealing concentrations below the maximum permitted by current legislation. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:432 / 435
页数:4
相关论文
共 32 条
  • [1] Electrochemical paper-based microfluidic devices
    Adkins, Jaclyn
    Boehle, Katherine
    Henry, Charles
    [J]. ELECTROPHORESIS, 2015, 36 (16) : 1811 - 1824
  • [2] ALUMINUM TOXICITY IN PATIENTS WITH CHRONIC-RENAL-FAILURE
    ALFREY, AC
    [J]. THERAPEUTIC DRUG MONITORING, 1993, 15 (06) : 593 - 597
  • [3] Antiperspirants and deodorants
    Benohanian, A
    [J]. CLINICS IN DERMATOLOGY, 2001, 19 (04) : 398 - 405
  • [4] Digital imaging as a detector for generic analytical measurements
    Byrne, L
    Barker, J
    Pennarun-Thomas, G
    Diamond, D
    Edwards, S
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (08) : 517 - 522
  • [5] Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
    Carrilho, Emanuel
    Martinez, Andres W.
    Whitesides, George M.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (16) : 7091 - 7095
  • [6] Flotation spectrophotometric determination of aluminum with alizarin
    Chamsaz, M
    Zavar, MHA
    Hosseini, MS
    [J]. ANALYTICAL LETTERS, 2000, 33 (08) : 1625 - 1633
  • [7] Aluminium and breast cancer: Sources of exposure, tissue measurements and mechanisms of toxicological actions on breast biology
    Darbre, Philippa D.
    Mannello, Ferdinando
    Exley, Christopher
    [J]. JOURNAL OF INORGANIC BIOCHEMISTRY, 2013, 128 : 257 - 261
  • [8] Draelos Z. D., 2012, DERMATOLOGIA COSMETI
  • [9] Use of multiple colorimetric indicators for paper-based microfluidic devices
    Dungchai, Wijitar
    Chailapakul, Orawon
    Henry, Charles S.
    [J]. ANALYTICA CHIMICA ACTA, 2010, 674 (02) : 227 - 233
  • [10] Egbuna O., 2004, INTERNET J NEPHROL, V2, P2