A performance comparison of serial and parallel solar-assisted heat pump heating systems in Xi'an, China

被引:41
作者
Huan, Chao [1 ,2 ]
Wang, Fenghao [2 ]
Li, Shengteng [1 ,3 ]
Zhao, Yujiao [1 ,3 ]
Liu, Lang [1 ,3 ]
Wang, Zhihua [2 ]
Ji, Changfa [1 ,3 ]
机构
[1] Xian Univ Sci & Technol, Energy Sch, Xian 710054, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian, Shaanxi, Peoples R China
[3] Minist Educ China, Key Lab Western Mines & Hazards Prevent, Xian, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
COP; solar energy; solar-assisted heat pump; TRNSYS; water heating system; DOMESTIC HOT-WATER; ENERGY; SIMULATIONS;
D O I
10.1002/ese3.357
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, a TRNSYS model for a solar-assisted heat pump (SAHP) water heating system for a university bathroom in Xi'an was developed and validated through experimental measurements. Under the typical meteorological conditions in Xi'an, a comparative analysis of the performance of the serial indirect expansion SAHP (IDX-SAHP) system and the parallel IDX-SAHP system during different seasons was conducted using the validated model. The results demonstrated that for annual operation, the parallel IDX-SAHP system showed better performance in the Xi'an district compared to the serial system. Under the same heating load, the average coefficient of performance (COP) of the serial IDX-SAHP system was 3.23 and that of the parallel IDX-SAHP system was 4.34. In particular, during summer and the transition season, the parallel IDX-SAHP system showed large advantages, mainly owing to a larger part of the heating load being provided by the solar collector. However, the serial IDX-SAHP system showed a higher efficiency than that of the parallel IDX-SAHP system during winter conditions.
引用
收藏
页码:1379 / 1393
页数:15
相关论文
共 40 条
[21]  
Li MZ, 2017, PROCEEDINGS OF 2017 CHINA INTERNATIONAL CONFERENCE ON INSURANCE AND RISK MANAGEMENT, P372
[22]   Performance of commercially available solar and heat pump water heaters [J].
Lloyd, C. R. ;
Kerr, A. S. D. .
ENERGY POLICY, 2008, 36 (10) :3807-3813
[23]  
[马洪亭 Ma Hongting], 2014, [太阳能学报, Acta Energiae Solaris Sinica], V35, P2152
[24]   DESCRIBING THE UNCERTAINTIES IN EXPERIMENTAL RESULTS [J].
MOFFAT, RJ .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1988, 1 (01) :3-17
[25]   Numerical analysis of the use of R-407C in direct expansion solar assisted heat pump [J].
Molinaroli, Luca ;
Joppolo, Cesare M. ;
De Antonellis, Stefano .
PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2013), 2014, 48 :938-945
[26]   Seasonal performance rating of heat pump water heaters [J].
Morrison, GL ;
Anderson, T ;
Behnia, M .
SOLAR ENERGY, 2004, 76 (1-3) :147-152
[27]   A method for the dynamic testing and evaluation of the performance of combined solar thermal heat pump hot water systems [J].
Panaras, G. ;
Mathioulakis, E. ;
Belessiotis, V. .
APPLIED ENERGY, 2014, 114 :124-134
[28]   Investigation of the performance of a combined solar thermal heat pump hot water system [J].
Panaras, G. ;
Mathioulakis, E. ;
Belessiotis, V. .
SOLAR ENERGY, 2013, 93 :169-182
[29]   Central solar heating plants with seasonal storage in Germany [J].
Schmidt, T ;
Mangold, D ;
Müller-Steinhagen, H .
SOLAR ENERGY, 2004, 76 (1-3) :165-174
[30]  
Standards B, 1297522001 BSEN