Fault Diagnosis and Tolerant Control of Dual-Active-Bridge Converter With Triple-Phase Shift Control for Bidirectional EV Charging Systems

被引:53
|
作者
Wen, Huiqing [1 ]
Li, Jinglin [1 ]
Shi, Haochen [2 ]
Hu, Yihua [3 ]
Yang, Yong [4 ]
机构
[1] Xian Jiaotong Liverpool Univ, Dept Elect & Elect Engn, Suzhou 215123, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[3] Univ York, Dept Elect Engn, York YO10 5DD, N Yorkshire, England
[4] Soochow Univ, Sch Rail Transportat, Suzhou 215131, Peoples R China
来源
IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION | 2021年 / 7卷 / 01期
关键词
Inductors; Fault diagnosis; Circuit faults; Voltage control; Transportation; Reliability; Power transmission; Bidirectional isolated dc; dc converter; fault analysis; operation modes; triple-phase-shift (TPS) control; DC-DC CONVERTER; TO-BACK CONVERTERS; DC/DC CONVERTER; RMS CURRENT; VOLTAGE; RELIABILITY; SWITCH;
D O I
10.1109/TTE.2020.3045673
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Efficiency and reliability are essential for isolated bidirectional dc-dc converters in electric vehicle (EV) battery charging systems. As one promising power interface between energy storage components and power bus, dual-active-bridge (DAB) dc-dc converters have gained wide applications due to the advantages of galvanic isolation, symmetric circuit structure, high power density, and easy control implementation. In this article, based on the triple-phase shift (TPS) control, a fast and effective fault diagnosis strategy is proposed for DAB converters to improve both the power conversion efficiency and reliability. First, the operation principle of DAB converters with TPS control is presented. Then, a fast and effective open-circuit fault (OCF) analysis under different operation modes of TPS control is presented. Based on the resonant phenomenon during the fault conditions, an OCF diagnosis strategy that uses midpoint voltage as diagnosis criteria is proposed for DAB converters under the advanced TPS control to identify the faulty devices quickly and avoid the system collapse. After the failure switches are located, fault-tolerant operation is adopted to maintain the power transmission ability of DAB converters and ensure safe operation. The experimental results are provided to validate the correctness and effectiveness of the OCF performance analysis, fault diagnosis, and tolerant method.
引用
收藏
页码:287 / 303
页数:17
相关论文
共 50 条
  • [1] Bidirectional Dual-Active-Bridge DC-DC Converter with Triple-Phase-Shift Control
    Wen, H.
    Xiao, W.
    2013 TWENTY-EIGHTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2013), 2013, : 1972 - 1978
  • [2] Fault Analysis and Fault-Tolerant Method of Dual Active Bridge Converter under Triple Phase Shift Control
    Shi, Haochen
    Wen, Huiqing
    Li, Jinglin
    2019 10TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE 2019 - ECCE ASIA), 2019,
  • [3] Current Stress Minimization and Optimal Control Strategy of Dual-Active-Bridge Converter With Bidirectional Inner Dual Phase Shift Control
    Deng, Zifeng
    Jin, Xinyu
    Kong, Lingchao
    Gong, Linxiao
    Wong, Yong
    2020 IEEE STUDENT CONFERENCE ON ELECTRIC MACHINES AND SYSTEMS (SCEMS 2020), 2020, : 762 - 768
  • [4] Triple Phase Shift Control of an LLL Tank Based Bidirectional Dual Active Bridge Converter
    Muthuraj, Shiva S.
    Kanakesh, V. K.
    Das, Pritam
    Panda, Sanjib Kumar
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (10) : 8035 - 8053
  • [5] The Dynamic Model and Hybrid Phase-Shift Control of a Dual-Active-Bridge Converter
    Bai, Hua
    Mi, Chunting
    Wang, Chongwu
    Gargies, Sonya
    IECON 2008: 34TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-5, PROCEEDINGS, 2008, : 2750 - +
  • [6] Power Characterization of Isolated Bidirectional Dual-Active-Bridge DC-DC Converter With Dual-Phase-Shift Control
    Zhao, Biao
    Song, Qiang
    Liu, Wenhua
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (09) : 4172 - 4176
  • [7] High Efficiency Dual-Active-Bridge Converter with Triple-Phase-Shift Control for Battery Charger of Electric Vehicles
    Kuo, Shih-hao
    Chiu, Huang-Jen
    Chiang, Che-Wei
    Huang, Ta-Wei
    Chang, Yu-Chen
    Bachman, Serafin
    Piasecki, Szymon
    Jasinski, Marek
    Turzynski, Marek
    ENERGIES, 2024, 17 (02)
  • [8] Novel Dual-Phase-Shift Control With Bidirectional Inner Phase Shifts for a Dual-Active-Bridge Converter Having Low Surge Current and Stable Power Control
    Liu, X.
    Zhu, Z. Q.
    Stone, David A.
    Foster, Martin P.
    Chu, W. Q.
    Urquhart, Iain
    Greenough, James
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (05) : 4095 - 4106
  • [9] Deep Reinforcement Learning Aided Variable-Frequency Triple-Phase-Shift Control for Dual-Active-Bridge Converter
    Tang, Yuanhong
    Hu, Weihao
    Cao, Di
    Hou, Nie
    Li, Zhuoqiang
    Li, Yun Wei
    Chen, Zhe
    Blaabjerg, Frede
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (10) : 10506 - 10515
  • [10] A Novel Dual-Phase-Shift Control Strategy for Dual-Active-Bridge DC-DC Converter
    Feng, Bo
    Wang, Yubin
    Man, Jingbin
    IECON 2014 - 40TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2014, : 4140 - 4145