共 37 条
Single breath-hold compressed sensing real-time cine imaging to assess left ventricular motion in myocardial infarction
被引:5
作者:
Longere, Benjamin
[1
,2
]
Chavent, Marc-Henry
[1
]
Coisne, Augustin
[2
,3
]
Gkizas, Christos
[1
]
Pagniez, Julien
[1
]
Simeone, Arianna
[1
]
Silvestri, Valentina
[1
]
Schmidt, Michaela
[4
]
Forman, Christoph
[4
]
Montaigne, David
[2
,3
]
Pontana, Francois
[1
,2
]
机构:
[1] CHU Lille, Inst Coeur Poumon, Dept Cardiovasc Radiol, Blvd Pr Jules Leclercq, F-59000 Lille, France
[2] Univ Lille, FR3508, EGID European Genom Inst Diabet, INSERM UMR 1011,Inst Pasteur Lille, F-59000 Lille, France
[3] CHU Lille, Dept Clin Physiol & Echocardiog, Lille, France
[4] Siemens Healthcare GmbH, Erlangen, Germany
关键词:
Cardiac magnetic resonance (CMR);
Compressed sensing;
Coronary artery disease;
Magnetic resonance imaging (MRI);
Myocardial infarction;
CARDIAC MAGNETIC-RESONANCE;
ITERATIVE RECONSTRUCTION;
DIASTOLIC FUNCTION;
HEART;
MRI;
CMR;
QUANTIFICATION;
RESOLUTION;
D O I:
10.1016/j.diii.2020.11.012
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: To evaluate the reliability of a real-time compressed sensing (CS) cine sequence for the detection of left ventricular wall motion disorders after myocardial infarction in comparison with the reference steady-state free precession cine sequence. Materials and Methods: One hundred consecutive adult patients referred for either initial work-up or follow-up by cardiac magnetic resonance (CMR) in the context of myocardial infarction were prospectively included. There were 77 men and 23 women with a mean age of 63.12 +/- 11.3 (SD) years (range: 29-89 years). Each patient underwent the reference segmented multi-breath-hold steady-state free precession cine sequence including one short-axis stack and both vertical and horizontal long-axis slices (SSFPref) and the CS real-time single-breath-hold evaluated sequence (CSrt) providing the same slices. Wall motion disorders were independently and blindly assessed with both sequences by two radiologists, using the American Heart Association left ventricle segmentation. Paired Wilcoxon signed-rank test was used to search for differences in wall motion disorders conspicuity between both sequences and receiver operating characteristic curve (ROC) analysis was performed to assess the diagnosis performance of CSrt sequence using SSFPref as the reference method. Results: Each patient had at least one cardiac segment with wall motion abnormality on SSFPref and CSrt images. The 1700 segments analyzed with SSFPref were classified as normokinetic (360/1700; 21.2%), hypokinetic (783/1700; 46.1%), akinetic (526/1700; 30.9%) or dyskinetic (31/1700; 1.8%). Sensitivity and specificity of the CS sequence were 99.6% (95% CI: 99.1-99.9%) and 99.7% (95% CI: 98.5-100%), respectively. Area under ROC of CSrt diagnosis performance was 0.997 (95% CI: 0.993-0.999). Conclusion: CS real-time cine imaging significantly reduces acquisition time without compromising the conspicuity of left ventricular-wall motion disorders in the context of myocardial infarction. (C) 2020 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:297 / 303
页数:7
相关论文