Cavopulmonary assist: Long-term reversal of the Fontan paradox

被引:38
|
作者
Rodefeld, Mark D. [1 ,2 ]
Marsden, Alison [3 ]
Figliola, Richard [4 ]
Jonas, Travis [5 ]
Neary, Michael [6 ]
Giridharan, Guruprasad A. [7 ]
机构
[1] Indiana Univ Sch Med, Sect Cardiothorac Surg, Dept Surg, Indianapolis, IN 46202 USA
[2] James Whitcomb Riley Hosp Children, 702 Barnhill Dr K-21, Indianapolis, IN 46202 USA
[3] Stanford Univ, Dept Bioengn & Pediat, Stanford, CA 94305 USA
[4] Clemson Univ, Dept Mech Engn, Clemson, SC USA
[5] Mech Solut Inc, Whippany, NJ USA
[6] Rotor Bearing Technol & Software Inc, Phoenixville, PA USA
[7] Univ Louisville, Dept Bioengn, Louisville, KY 40292 USA
基金
美国国家卫生研究院;
关键词
Fontan; single ventricle; mechanical circulatory support; MECHANICAL CIRCULATORY SUPPORT; CONGENITAL HEART-DISEASE; FOLLOW-UP; TRANSPLANTATION; HEMODYNAMICS; CHALLENGE; OPERATION; OUTCOMES;
D O I
10.1016/j.jtcvs.2019.06.112
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Fontan circulatory inefficiency can be addressed by replacing the missing subpulmonary power source to reverse the Fontan paradox. An implantable cavopulmonary assist device is described that will simultaneously reduce systemic venous pressure and increase pulmonary arterial pressure, improving preload and cardiac output, in a univentricular Fontan circulation on a long-term basis. Methods: A rotary blood pump that was based on the von Karman viscous pump was designed for implantation into the total cavopulmonary connection (TCPC). It will impart modest pressure energy to augment Fontan flow without risk of obstruction. In the event of rotational failure, it is designed to default to a passive flow diverter. Pressure-flow performance was characterized in vitro in a Fontan mock circulatory loop with blood analog. Results: The pump performed through the fully specified operating range, augmenting flow in all 4 directions of the TCPC. Pressure rise of 6 to 8 mm Hg was readily achieved, ranging to 14 mm Hg at highest speed (5600 rpm). Performance was consistent across a wide range of cardiac outputs. In stalled condition (0 rpm), there was no discernible pressure loss across the TCPC. Conclusions: A blood pump technology is described that can reverse the Fontan paradox and may permit a surgical strategy of long-term biventricular maintenance of a univentricular Fontan circulation. The technology is intended for Fontan failure in which right-sided circulatory inefficiencies predominate and ventricular systolic function is preserved. It may also apply before clinical Fontan failure as health maintenance to preempt the progression of Fontan disease.
引用
收藏
页码:1627 / 1635
页数:9
相关论文
共 50 条
  • [1] A Cavopulmonary Assist Device for Long-Term Therapy of Fontan Patients
    Escher, Andreas
    Strauch, Carsten
    Hubmann, Emanuel J.
    Huebler, Michael
    Bortis, Dominik
    Thamsen, Bente
    Mueller, Marc
    Kertzscher, Ulrich
    Thamsen, Paul U.
    Kolar, Johann W.
    Zimpfer, Daniel
    Granegger, Marcus
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2022, 34 (01) : 238 - 248
  • [2] A long-term mechanical cavopulmonary support device for patients with Fontan circulation
    Granegger, Marcus
    Thamsen, Bente
    Hubmann, Emanuel J.
    Choi, Young
    Beck, Dominik
    Buechel, Emanuela Valsangiacomo
    Voutat, Michael
    Schweiger, Martin
    Meboldt, Mirko
    Hubler, Michael
    MEDICAL ENGINEERING & PHYSICS, 2019, 70 : 9 - 18
  • [3] Long-term outcomes of patients with single ventricle who do not undergo Fontan palliation
    Zheng, Wayne C.
    d'Udekem, Yves
    Grigg, Leeanne E.
    Zentner, Dominica
    Cordina, Rachael
    Celermajer, David S.
    Buratto, Edward
    Konstantinov, Igor E.
    Lee, Melissa G. Y.
    INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE, 2023, 12
  • [4] Long-term management of Fontan patients: The importance of a multidisciplinary approach
    Martino, Diletta
    Rizzardi, Caterina
    Vigezzi, Serena
    Guariento, Chiara
    Sturniolo, Giulia
    Tesser, Francesca
    di Salvo, Giovanni
    FRONTIERS IN PEDIATRICS, 2022, 10
  • [5] Long-term follow-up of Fontan completion in adults and adolescents
    Fuchigami, Tai
    Nagashima, Mitsugi
    Hiramatsu, Takeshi
    Matsumura, Goki
    Tateishi, Minori
    Masuda, Noriyasu
    Yamazaki, Kenji
    JOURNAL OF CARDIAC SURGERY, 2017, 32 (07) : 436 - 442
  • [6] Anatomical Compliance of Cavopulmonary Assist Device Designs: A Virtual Fitting Study in Fontan Patients
    Karner, Barbara
    Escher, Andreas
    Schorn, Therese
    Narayanaswamy, Krishnaraj
    Sachweh, Joerg
    Laufer, Guenther
    Huebler, Michael
    Zimpfer, Daniel
    Granegger, Marcus
    ASAIO JOURNAL, 2023, 69 (11) : 1016 - 1024
  • [7] Long-term outcomes of direct total cavopulmonary connection versus extracardiac conduit in Fontan circulation
    Ma, Jianrui
    Han, Linjiang
    He, Yinru
    Tian, Miao
    Wei, Peijian
    Tan, Tang
    Zhou, Ziqin
    Gao, Manchen
    Liu, Xiaobing
    Yuan, Haiyun
    Chen, Jimei
    JTCVS TECHNIQUES, 2025, 29 : 129 - 137
  • [8] Long-term survival after the Fontan operation: Twenty years of experience at a single center
    Downing, Tacy E.
    Allen, Kiona Y.
    Glatz, Andrew C.
    Rogers, Lindsay S.
    Ravishankar, Chitra
    Rychik, Jack
    Faerber, Jennifer A.
    Fuller, Stephanie
    Montenegro, Lisa M.
    Steven, James M.
    Spray, Thomas L.
    Nicolson, Susan C.
    Gaynor, J. William
    Goldberg, David J.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 154 (01) : 243 - +
  • [9] PULMONARY ARTERY SIZE AT THE TIME OF BIDIRECTIONAL CAVOPULMONARY SHUNT AND FONTAN SURGERY INFLUENCES LONG-TERM OUTCOMES
    Xu, Mary Y.
    Kowalski, Remi
    d'Udekem, Yves
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 143 (04) : 989 - 990
  • [10] Perioperative and long-term management of Fontan patients
    Al-Shawk, May
    Banjoko, Adeolu
    Axiaq, Ariana
    Amin, Kiran
    Harky, Amer
    CARDIOLOGY IN THE YOUNG, 2021, 31 (05) : 775 - 785