Effect of embedded printed circuit board (PCB) sensors on the mechanical behavior of glass fiber-reinforced polymer (GFRP) structures

被引:6
作者
Javdanitehran, M. [1 ]
Hoffmann, R. [2 ]
Groh, J. [3 ]
Vossiek, M. [3 ]
Ziegmann, G. [1 ]
机构
[1] Tech Univ Clausthal, Clausthal Ctr Mat Technol, Agricolastr 2, Clausthal Zellerfeld, Germany
[2] Tech Univ Clausthal, Inst Polymer Mat & Plast Engn, Agricolastr 6, Clausthal Zellerfeld, Germany
[3] Univ Erlangen Nurnberg, Inst Microwaves & Photon LHFT, Cauerstr 9, D-91054 Erlangen, Germany
关键词
glass fibres; embedded sensor; mechanical properties; analytical modelling; OPTICAL-FIBERS; COMPOSITES; TENSILE; DAMAGE;
D O I
10.1088/0964-1726/25/6/065016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The embedding of dielectric chipless sensors for cure monitoring into fiber-reinforced thermosets allows for monitoring and controlling the curing process and consequently higher quality in production. The embedded sensors remain after the processing in the structure. This affects the integrity of the composite structure locally. In order to investigate these effects on the mechanical behavior of the glass fiber-reinforced polymer (GFRP), sensors made on special low loss substrates are integrated into laminates with different lay-ups and thicknesses using vacuum assisted resin transfer molding (VARTM) method. In a parametric study the size of the sensor is varied to observe its influence on the strength and the stiffness of the laminates according to its lay-up and thickness. The size and orientation of the resin rich areas near sensors as well as the distortion in load bearing area as the consequences of the introduction of the sensors are investigated in conjunction with the strength of the structure. An empirical model is proposed by the authors which involves the previously mentioned factors and is used as a rapid tool for the prediction of the changes in bending and tensile strength of simple structures with embedded sensors. The methodology for model's calibration as well as the validation of the model against the experimental data of different laminates with distinct lay-ups and thicknesses are presented in this work. Mechanical tests under tensile and bending loading indicate that the reduction of the structure's strength due to sensor integration can be attributed to the size and the orientation of rich resin zones and depends over and above on the size of distorted load bearing area. Depending on the sensor's elastic modulus the stiffness of the structure may vary through the introduction of a sensor.
引用
收藏
页数:11
相关论文
共 33 条
  • [21] Performance Improvement Method of CFRP with Embedded Optical Fiber
    刘荣梅
    肖军
    梁大开
    王桂娜
    [J]. Transactions of Nanjing University of Aeronautics and Astronautics, 2015, 32 (03) : 261 - 267
  • [22] Monotonic and fatigue loading behavior of quasi-isotropic graphite/epoxy laminate embedded with piezoelectric sensor
    Mall, S
    Coleman, JM
    [J]. SMART MATERIALS & STRUCTURES, 1998, 7 (06) : 822 - 832
  • [23] Use of piezoelectric as acoustic emission sensor for in situ monitoring of composite structures
    Masmoudi, Sahir
    El Mahi, Abderrahim
    Turki, Said
    [J]. COMPOSITES PART B-ENGINEERING, 2015, 80 : 307 - 320
  • [24] Model evaluation guidelines for systematic quantification of accuracy in watershed simulations
    Moriasi, D. N.
    Arnold, J. G.
    Van Liew, M. W.
    Bingner, R. L.
    Harmel, R. D.
    Veith, T. L.
    [J]. TRANSACTIONS OF THE ASABE, 2007, 50 (03) : 885 - 900
  • [25] Structural assessment of microvascular self-healing laminates using progressive damage finite element analysis
    Nguyen, Alex T. T.
    Orifici, Adrian C.
    [J]. COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2012, 43 (11) : 1886 - 1894
  • [26] Rahman M., 2011, International Journal of Education Research, V6, P9
  • [27] Roellig M, 2012, P 6 EUR WORK STRUCT, P981
  • [28] Mechanical properties of composite materials with integrated embedded sensor networks
    Schaaf, K
    Cook, B
    Ghezzo, F
    Starr, A
    Nemat-Nasser, S
    [J]. Smart Structures and Materials 2005: Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace, Pts 1 and 2, 2005, 5765 : 781 - 785
  • [29] Failure mechanics of a composite laminate embedded with a fiber optic sensor
    Shivakumar, K
    Bhargava, A
    [J]. JOURNAL OF COMPOSITE MATERIALS, 2005, 39 (09) : 777 - 798
  • [30] The Effect of Different Optical Fibers on The Tensile Property of CFRPs
    Tian, Heng
    Wang, Jihui
    Ji, Yundong
    Hao, Xufeng
    Yin, Yanzi
    Sun, Jiuxiao
    [J]. EMERGING FOCUS ON ADVANCED MATERIALS, PTS 1 AND 2, 2011, 306-307 : 884 - +