The nocturnal acoustical intensity of the intensive care environment: an observational study

被引:38
作者
Delaney, Lori J. [1 ,2 ,8 ]
Currie, Marian J. [1 ,2 ]
Huang, Hsin-Chia Carol [3 ]
Lopez, Violeta [4 ,5 ]
Litton, Edward [5 ,6 ]
Van Haren, Frank [2 ,7 ]
机构
[1] Univ Canberra, Fac Nursing, Canberra, ACT, Australia
[2] Australian Natl Univ, Coll Med Biol & Environm, Canberra, ACT, Australia
[3] Canberra Hosp, Resp & Sleep Med, Canberra, ACT, Australia
[4] Yong Loo Lin Sch Med, Alice Lee Ctr Nursing Studies, Singapore, Singapore
[5] St John God Hosp, Subiaco, WA, Australia
[6] Univ Western Australia, Sch Med & Pharmacol, Perth, WA 6009, Australia
[7] Canberra Hosp, Intens Care Unit, Canberra, ACT, Australia
[8] Univ Canberra, Discipline Nursing, Fac Hlth, Canberra, ACT 2601, Australia
关键词
Critical care; Disturbance; Intensive care; Noise; Sleep disturbance; Staff; SLEEP DISRUPTION; UNIT; NOISE; ICU; POLYSOMNOGRAPHY; METAANALYSIS; PERCEPTION; QUALITY; ROOMS;
D O I
10.1186/s40560-017-0237-9
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The intensive care unit (ICU) environment exposes patients to noise levels that may result in substantial sleep disruption. There is a need to accurately describe the intensity pattern and source of noise in the ICU in order to develop effective sound abatement strategies. The objectives of this study were to determine nocturnal noise levels and their variability and the related sources of noise within an Australian tertiary ICU. Methods: An observational cross-sectional study was conducted in a 24-bed open-plan ICU. Sound levels were recorded overnight during three nights at 5-s epochs using Extech (SDL 600) sound monitors. Noise sources were concurrently logged by two research assistants. Results: The mean recorded ambient noise level in the ICU was 52.85 decibels (dB) (standard deviation (SD) 5.89), with a maximum noise recording at 98.3 dB (A). All recorded measurements exceeded the WHO recommendations. Noise variability per minute ranged from 9.9 to 44 dB (A), with peak noise levels > 70 dB (A) occurring 10 times/hour (SD 11.4). Staff were identified as the most common source accounting for 35% of all noise. Mean noise levels in single-patient rooms compared with open-bed areas were 53.5 vs 53 dB (p = 0.37), respectively. Conclusion: Mean noise levels exceeded those recommended by the WHO resulting in an acoustical intensity of 193 times greater than the recommended and demonstrated a high degree of unpredictable variability, with the primary noise sources coming from staff conversations. The lack of protective effects of single rooms and the contributing effects that staffs have on noise levels are important factors when considering sound abatement strategies.
引用
收藏
页数:8
相关论文
共 49 条
[1]   Environmental noise as a cause of sleep disruption in an intermediate respiratory care unit [J].
Aaron, JN ;
Carlisle, CC ;
Carskadon, MA ;
Meyer, TJ ;
Hill, NS ;
Millman, RP .
SLEEP, 1996, 19 (09) :707-710
[2]   SLEEP IN THE SURGICAL INTENSIVE-CARE UNIT - CONTINUOUS POLYGRAPHIC RECORDING OF SLEEP IN 9 PATIENTS RECEIVING POSTOPERATIVE CARE [J].
AURELL, J ;
ELMQVIST, D .
BRITISH MEDICAL JOURNAL, 1985, 290 (6474) :1029-1032
[3]   NOISE IN THE ICU [J].
BALOGH, D ;
KITTINGER, E ;
BENZER, A ;
HACKL, JM .
INTENSIVE CARE MEDICINE, 1993, 19 (06) :343-346
[4]   Sleep monitoring in the intensive care unit: comparison of nurse assessment, actigraphy and polysomnography [J].
Beecroft, Jaime M. ;
Ward, Michael ;
Younes, Magdy ;
Crombach, Shelley ;
Smith, Orla ;
Hanly, Patrick J. .
INTENSIVE CARE MEDICINE, 2008, 34 (11) :2076-2083
[5]  
Berglund B., 1999, World health organization: Guidelines for community noise
[6]  
Call R.B., 2007, Academy Journal
[7]   Nurses' perception of single-occupancy versus multioccupancy rooms in acute care environments: An exploratory comparative assessment [J].
Chaudhury, Habib ;
Mahmood, Atlya ;
Valente, Maria .
APPLIED NURSING RESEARCH, 2006, 19 (03) :118-125
[8]  
Christensen Martin, 2007, Nurs Crit Care, V12, P188, DOI 10.1111/j.1478-5153.2007.00229.x
[9]  
Connor Alison, 2009, Perm J, V13, P23
[10]  
Delaney L., 2014, JBI Database System Reviews and Implementation Reports, V12, P505