Accuracy and repeatability of single-pose calibration of inertial measurement units for whole-body motion analysis

被引:75
|
作者
Robert-Lachaine, Xavier [1 ]
Mecheri, Hakim [1 ]
Larue, Christian [1 ]
Plamondon, Andre [1 ]
机构
[1] Inst Rech Robert Sauve Sante & Securite Travail, 505 Boul Maisonneuve Ouest, Montreal, PQ H3A 3C2, Canada
关键词
Inertial sensor; Posture; Error; Kinematics; Precision; Similarity; HUMAN JOINT MOTION; MAGNETIC SENSORS; AMBULATORY MEASUREMENT; ISB RECOMMENDATION; KINEMATICS; SHOULDER; RELIABILITY; MOVEMENT; STEREOPHOTOGRAMMETRY; DEFINITIONS;
D O I
10.1016/j.gaitpost.2017.02.029
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Portable inertial measurement units (IMUs) are suitable for motion analysis outside the laboratory. However, IMUs depend on the calibration of each body segment to measure human movement. Different calibration approaches have been developed for simplicity of use or similarity to laboratory motion analysis, but they have not been extensively examined. The main objective of the study was to determine the accuracy and repeatability of two common single-pose calibrations (N-pose and T-pose) under different conditions of placement (self-placement and passive placement), as well as their similarity to laboratory analysis based on anatomical landmarks. A further aim of the study was to develop two additional single-pose calibrations (chair-pose and stool-pose) and determine their accuracy and repeatability. Postures and movements of 12 healthy participants were recorded simultaneously with a full-body IMU suit and an optoelectronic system as the criterion measure. Three repetitions of the T-pose and the N-pose were executed by self-placement and passive placement, and three repetitions of the chair-pose and stool-pose were also performed. Repeatability for each single-pose calibration showed an average intraclass correlation coefficient for all axes and joints between 0.90 and 0.94 and a standard error of measurement between 1.5 degrees and 2.1 degrees. The T-pose with passive placement is recommended to reduce longitudinal axis offset error and to increase similarity to laboratory motion analysis. Finally, the chair-pose obtained the least longitudinal axis offset error amongst the tested poses, which shows potential for IMU calibration. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:80 / 86
页数:7
相关论文
共 50 条
  • [31] ANTHROPOMORPHIC MODELS FOR CHECKING THE CALIBRATION OF WHOLE-BODY COUNTERS AND ACTIVATION-ANALYSIS SYSTEMS
    BEWLEY, DK
    PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (07): : 805 - 813
  • [32] Synthetized inertial measurement units (IMUs) to evaluate the placement of wearable sensors on human body for motion recognition
    Hoareau, Damien
    Jodin, Gurvan
    Chantal, Pierre-Antoine
    Bretin, Sara
    Prioux, Jacques
    Razan, Florence
    Journal of Engineering, 2022, 2022 (05): : 536 - 543
  • [33] Synthetized inertial measurement units (IMUs) to evaluate the placement of wearable sensors on human body for motion recognition
    Hoareau, Damien
    Jodin, Gurvan
    Chantal, Pierre-Antoine
    Bretin, Sara
    Prioux, Jacques
    Razan, Florence
    JOURNAL OF ENGINEERING-JOE, 2022, 2022 (05): : 536 - 543
  • [34] MEASUREMENT OF WHOLE-BODY OXYGEN IN LIVING HUMANS BY NEUTRON-ACTIVATION ANALYSIS
    WILLIAMS, ED
    BODDY, K
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1978, 29 (4-5): : 281 - 283
  • [35] UPPER BODY JOINT ANGLE CALCULATION AND ANALYSIS USING MULTIPLE INERTIAL MEASUREMENT UNITS
    Freedkin, Aaron S.
    Ryu, Ji-Chul
    Hwang, Jaejin
    PROCEEDINGS OF ASME 2023 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2023, VOL 5, 2023,
  • [36] Whole-body motion retargeting using constrained smoothing and functional principle component analysis
    Morishima, Saori
    Ayusawa, Ko
    Yoshida, Eiichi
    Venture, Gentiane
    2016 IEEE-RAS 16TH INTERNATIONAL CONFERENCE ON HUMANOID ROBOTS (HUMANOIDS), 2016, : 294 - 299
  • [37] Repeatability of an off-the-shelf, full body inertial motion capture system during clinical gait analysis
    Cloete, Teunis
    Scheffer, Cornie
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 5125 - 5128
  • [38] Physical Fatigue Analysis of Assistive Robot Teleoperation via Whole-body Motion Mapping
    Lin, Tsung-Chi
    Krishnan, Achyuthan Unni
    Li, Zhi
    2019 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2019, : 2240 - 2245
  • [39] Whole-body single-frequency bioimpedance analysis in pediatric hemodialysis patients
    Oh, Gia
    Wong, Cynthia
    Begin, Brandy
    Salsbery, Kari
    Sutherland, Scott
    Chaudhuri, Abanti
    PEDIATRIC NEPHROLOGY, 2014, 29 (08) : 1417 - 1423
  • [40] Whole-body single-frequency bioimpedance analysis in pediatric hemodialysis patients
    Gia Oh
    Cynthia Wong
    Brandy Begin
    Kari Salsbery
    Scott Sutherland
    Abanti Chaudhuri
    Pediatric Nephrology, 2014, 29 : 1417 - 1423