Accuracy and repeatability of single-pose calibration of inertial measurement units for whole-body motion analysis

被引:75
|
作者
Robert-Lachaine, Xavier [1 ]
Mecheri, Hakim [1 ]
Larue, Christian [1 ]
Plamondon, Andre [1 ]
机构
[1] Inst Rech Robert Sauve Sante & Securite Travail, 505 Boul Maisonneuve Ouest, Montreal, PQ H3A 3C2, Canada
关键词
Inertial sensor; Posture; Error; Kinematics; Precision; Similarity; HUMAN JOINT MOTION; MAGNETIC SENSORS; AMBULATORY MEASUREMENT; ISB RECOMMENDATION; KINEMATICS; SHOULDER; RELIABILITY; MOVEMENT; STEREOPHOTOGRAMMETRY; DEFINITIONS;
D O I
10.1016/j.gaitpost.2017.02.029
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Portable inertial measurement units (IMUs) are suitable for motion analysis outside the laboratory. However, IMUs depend on the calibration of each body segment to measure human movement. Different calibration approaches have been developed for simplicity of use or similarity to laboratory motion analysis, but they have not been extensively examined. The main objective of the study was to determine the accuracy and repeatability of two common single-pose calibrations (N-pose and T-pose) under different conditions of placement (self-placement and passive placement), as well as their similarity to laboratory analysis based on anatomical landmarks. A further aim of the study was to develop two additional single-pose calibrations (chair-pose and stool-pose) and determine their accuracy and repeatability. Postures and movements of 12 healthy participants were recorded simultaneously with a full-body IMU suit and an optoelectronic system as the criterion measure. Three repetitions of the T-pose and the N-pose were executed by self-placement and passive placement, and three repetitions of the chair-pose and stool-pose were also performed. Repeatability for each single-pose calibration showed an average intraclass correlation coefficient for all axes and joints between 0.90 and 0.94 and a standard error of measurement between 1.5 degrees and 2.1 degrees. The T-pose with passive placement is recommended to reduce longitudinal axis offset error and to increase similarity to laboratory motion analysis. Finally, the chair-pose obtained the least longitudinal axis offset error amongst the tested poses, which shows potential for IMU calibration. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:80 / 86
页数:7
相关论文
共 50 条
  • [1] Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis
    Robert-Lachaine, Xavier
    Mecheri, Hakim
    Larue, Christian
    Plamondon, Andre
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (04) : 609 - 619
  • [2] Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis
    Xavier Robert-Lachaine
    Hakim Mecheri
    Christian Larue
    André Plamondon
    Medical & Biological Engineering & Computing, 2017, 55 : 609 - 619
  • [3] Personalized Online Learning of Whole-Body Motion Classes using Multiple Inertial Measurement Units
    Losing, Viktor
    Yoshikawa, Taizo
    Hasenjaeger, Martina
    Hammer, Barbara
    Wersing, Heiko
    2019 INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2019, : 9530 - 9536
  • [4] Estimating Whole-Body Walking Motion from Inertial Measurement Units at Wrist and Heels Using Deep Learning
    Kumano, Yuji
    Kanoga, Suguru
    Yamamoto, Masataka
    Takemura, Hiroshi
    Tada, Mitsunori
    INTERNATIONAL JOURNAL OF AUTOMATION TECHNOLOGY, 2023, 17 (03) : 217 - 225
  • [5] Accuracy of Whole-Body Plethysmography Requires Biological Calibration
    Poorisrisak, Porntiva
    Vrang, Carsten
    Henriksen, Jorn Molgaard.
    Klug, Bent
    Hanel, Birgitte
    Bisgaard, Hans
    CHEST, 2009, 135 (06) : 1476 - 1480
  • [6] Estimating whole-body centre of mass sway during quiet standing with inertial measurement units
    Foulger, Liam H.
    Reiter, Emma R.
    Kuo, Calvin
    Carpenter, Mark G.
    Blouin, Jean-Sebastien
    PLOS ONE, 2025, 20 (01):
  • [7] Single-Network Whole-Body Pose Estimation
    Hidalgo, Gines
    Raaj, Yaadhav
    Idrees, Haroon
    Xiang, Donglai
    Joo, Hanbyul
    Simon, Tomas
    Sheikh, Yaser
    2019 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV 2019), 2019, : 6981 - 6990
  • [8] Validation of a low-cost inertial motion capture system for whole-body motion analysis
    Robert-Lachaine, X.
    Mecheri, H.
    Muller, A.
    Larue, C.
    Plamondon, A.
    JOURNAL OF BIOMECHANICS, 2020, 99
  • [9] Sensor-to-body calibration procedure for clinical motion analysis of lower limb using magnetic and inertial measurement units
    Nazarahari, Milad
    Noamani, Alireza
    Ahmadian, Niloufar
    Rouhani, Hossein
    JOURNAL OF BIOMECHANICS, 2019, 85 : 224 - 229
  • [10] Systematic Calibration for Ultra-High Accuracy Inertial Measurement Units
    Cai, Qingzhong
    Yang, Gongliu
    Song, Ningfang
    Liu, Yiliang
    SENSORS, 2016, 16 (06)