Preconcentration and flame atomic absorption spectrometry determination of cadmium in mussels by an on-line continuous precipitation-dissolution flow system

被引:19
作者
Yebra, MC [1 ]
Enríquez, MF [1 ]
Cespón, RM [1 ]
机构
[1] Univ Santiago, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15706, Spain
关键词
flame atomic absorption spectrometry; flow analysis; precipitation and dissolution; cadmium; mussels;
D O I
10.1016/S0039-9140(00)00367-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid, sensitive, accurate and precise flame atomic absorption method is described for the determination of cadmium in mussels. The method is based on the continuous precipitation of cadmium as an ion pair between tetraiodocadmate and quinine and dissolution of the precipitate with ethanol. The metal can be preconcentrated 32-fold using 15 ml of sample solution by using a time-based technique at a sampling flow rate of 3.0 ml min(-1). The proposed method allows the determination of cadmium in the range 0.25-5.5 mu g g(-1). The precision (relative standard deviation) obtained for different amounts of cadmium is in the range 1.5-4.7% at the 0.25-5.0 mu g g(-1) level. The method demonstrates high tolerance to interferences, and the data obtained are in agreement with the certified value of a selected reference material. This procedure was applied to the determination of cadmium in mussel samples from estuaries in Galicia (Spain). (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:631 / 636
页数:6
相关论文
共 22 条
[1]   Preconcentration and speciation of chromium by the determination of total chromium and chromium(III) in natural waters by flame atomic absorption spectrometry with a chelating ion-exchange flow injection system [J].
CesponRomero, RM ;
YebraBiurrun, MC ;
BermejoBarrera, MP .
ANALYTICA CHIMICA ACTA, 1996, 327 (01) :37-45
[2]   Flow injection on-line coprecipitation-preconcentration system using copper(II) diethyldithiocarbamate as carrier for flame atomic absorption spectrometric determination of cadmium, lead and nickel in environmental samples [J].
Chen, HW ;
Jin, JC ;
Wang, YF .
ANALYTICA CHIMICA ACTA, 1997, 353 (2-3) :181-188
[3]   FLAME ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF CADMIUM IN BIOLOGICAL SAMPLES USING A PRECONCENTRATION FLOW SYSTEM WITH AN ACTIVATED CARBON COLUMN AND DITHIZONE AS A CHELATING AGENT [J].
DEPENA, YP ;
GALLEGO, M ;
VALCARCEL, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (06) :691-696
[4]   On-line precipitation/dissolution system for the preconcentration and determination of manganese traces by atomic absorption spectrometry [J].
Dittfurth, C ;
Ballesteros, E ;
Gallego, M ;
Valcarcel, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (14) :1935-1941
[5]   Determination of cadmium in mussels by flame atomic absorption spectrometry with preconcentration on a chelating resin in a flow injection system [J].
Enríquez-Domínguez, MF ;
Yebra-Biurrun, MC ;
Bermejo-Barrera, MP .
ANALYST, 1998, 123 (01) :105-108
[6]  
ESMADI FT, 1992, CAN J APPL SPECTROSC, V37, P119
[7]  
Fang Z., 1993, FLOW INJECTION SEPAR
[8]  
FURNEE RW, 1988, HEAVY METALS MARINE
[9]  
Kartikeyan S, 1997, ANAL LETT, V30, P1037
[10]  
KUCEROVA H, 1975, PLANTA MED, V27, P185