Comparison of precipitation chemistry measurements obtained by the Canadian Air and Precipitation Monitoring Network and National Atmospheric Deposition Program for the period 1995-2004

被引:10
作者
Wetherbee, Gregory A. [1 ]
Shaw, Michael J. [2 ]
Latysh, Natalie E. [3 ]
Lehmann, Christopher M. B. [4 ]
Rothert, Jane E. [4 ]
机构
[1] US Geol Survey, Branch Qual Syst, Denver Fed Ctr, Denver, CO 80225 USA
[2] Environm Canada, Toronto, ON M3H 5T4, Canada
[3] US Geol Survey, Geospatial Informat Off, Denver Fed Ctr, Denver, CO 80225 USA
[4] Illinois State Water Survey, Champaign, IL 61820 USA
关键词
Acid rain; Acidic deposition; CAPMoN; Composite samples; NADP/NTN; Network comparability; Precipitation chemistry; CAPMON;
D O I
10.1007/s10661-009-0879-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Precipitation chemistry and depth measurements obtained by the Canadian Air and Precipitation Monitoring Network (CAPMoN) and the US National Atmospheric Deposition Program/National Trends Network (NADP/NTN) were compared for the 10-year period 1995-2004. Colocated sets of CAPMoN and NADP instrumentation, consisting of precipitation collectors and rain gages, were operated simultaneously per standard protocols for each network at Sutton, Ontario and Frelighsburg, Ontario, Canada and at State College, PA, USA. CAPMoN samples were collected daily, and NADP samples were collected weekly, and samples were analyzed exclusively by each network's laboratory for pH, H(+), Ca(2+), Mg(2+), Na(+), K(+), NH(4)(+), Cl(-), NO(3)(-), and SO(4)(2-). Weekly and annual precipitation-weighted mean concentrations for each network were compared. This study is a follow-up to an earlier internetwork comparison for the period 1986-1993, published by Alain Sirois, Robert Vet, and Dennis Lamb in 2000. Median weekly internetwork differences for 1995-2004 data were the same to slightly lower than for data for the previous study period (1986-1993) for all analytes except NO(3)(-), SO(4)(2-), and sample depth. A 1994 NADP sampling protocol change and a 1998 change in the types of filters used to process NADP samples reversed the previously identified negative bias in NADP data for hydrogen-ion and sodium concentrations. Statistically significant biases (alpha = 0.10) for sodium and hydrogen-ion concentrations observed in the 1986-1993 data were not significant for 1995-2004. Weekly CAPMoN measurements generally are higher than weekly NADP measurements due to differences in sample filtration and field instrumentation, not sample evaporation, contamination, or analytical laboratory differences.
引用
收藏
页码:111 / 132
页数:22
相关论文
共 23 条
  • [1] [Anonymous], 1985, The Elements of Graphing Data
  • [2] [Anonymous], 1989, SAS STAT US GUID VER
  • [3] *CAPMON, 1985, CAPMON OP INSTR MAN
  • [4] GOODISON BE, 1989, IAHS PUBL, V179, P57
  • [5] GORDON JD, 1997, 974201 USGS WAT RES
  • [6] GORDON JD, 1999, 994072 USGS, P42
  • [7] GORDON JD, 2003, 034027 USGS, P24
  • [8] HELSEL DR, 2005, 20055275 US GEOL SUR
  • [9] KANJI HK, 1993, 100 STAT TESTS NEWBU
  • [10] Critical evaluation of a modified automatic wet-only precipitation collector for mercury and trace element determinations
    Landis, MS
    Keeler, GJ
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (09) : 2610 - 2615