Simultaneous Determination of Trace Elements and Lead Isotopes in Fused Silicate Rock Powders Using a Boron Nitride Vessel and fsLA-(MC)-ICP-MS

被引:67
作者
Bao Zhian [1 ]
Yuan Honglin [1 ]
Zong Chunlei [1 ]
Liu Ye [1 ]
Chen Kaiyun [1 ]
Zhang Yulin [1 ]
机构
[1] NW Univ Xian, Dept Geol, State Key Lab Continental Dynam, Xian 710069, Peoples R China
基金
中国国家自然科学基金;
关键词
LA-ICP-MS; PLASMA-MASS SPECTROMETRY; NM ND-YAG; GEOLOGICAL GLASSES; RATIO MEASUREMENT; LASER; ABLATION; BHVO-2G; SAMPLES; HEATER;
D O I
10.1039/c5ja00410a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new glass-making method was developed to allow the in situ analysis of trace elements and lead isotopes in rock samples. The apparatus used to prepare homogeneous glass samples from silicate rock powder consisted of a small (450 mm(3)) boron nitride vessel and a high-temperature furnace. The concentrations of trace elements were measured by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and lead isotopic compositions were measured by femtosecond laser ablation multicollector inductively coupled plasma mass spectrometry (fsLA-MC-ICP-MS). The method was evaluated by analyzing glass disks fused from six geochemical reference materials (spanning the compositional range basalt-andesite-rhyolite). The measured 34 trace element contents match the reference values within 15%, and the mean Pb isotopic ratios measured by fsLA-MC-ICP-MS agree with those obtained by solution nebulizer MC-ICP-MS within 2s uncertainty intervals. By using seven Faraday cups operating in static mode we were able to obtain Pb-207/Pb-206 and Pb-208/Pb-206 results with improved precisions by a factor of 2-3 compared to those obtained by previous single-collector sector-field ICPMS and LA-MC-ICP-MS. The accuracies of Pb-207/Pb-206 and Pb-208/Pb-206 values obtained by fsLA-MC-ICP-MS lie between -0.073% and +0.023%, which are well determined for geological research. Measured Pb-208/Pb-204, Pb-207/Pb-204 and Pb-206/Pb-204 isotope ratios for the USGS reference RGM-2 (20 mu g g(-1) total Pb) and BCR-2 (11 mu g g(-1) total Pb) agree within 0.029% and 0.055% respectively of the preferred values. For GSR-3 (4.27 mu g g(-1) total Pb), the accuracies of the Pb-208/Pb-204, Pb-207/Pb-204 and Pb-206/Pb-204 ratios obtained by fsLA-MC-ICP-MS lie between -0.064% and -0.004% with the accepted external precision of <0.15% (1RSD), which are better than previous LA-MC-ICP-MS data in terms of quantification limits. We also provide precise Pb isotopic data for the reference materials GSR-2, GSR-3, QLO-1, and RGM-2 obtained by solution nebulizer MC-ICP-MS. Our method is simpler, cheaper and faster to determine trace elements and Pb isotopic ratios in geological samples, while retaining similar levels of accuracy and precision.
引用
收藏
页码:1012 / 1022
页数:11
相关论文
共 37 条
[1]   Pb isotopic analysis of standards and samples using a 207Pb-204Pb double spike and thallium to correct for mass bias with a double-focusing MC-ICP-MS [J].
Baker, J ;
Peate, D ;
Waight, T ;
Meyzen, C .
CHEMICAL GEOLOGY, 2004, 211 (3-4) :275-303
[2]  
[包志安 BAO Zhian], 2011, [岩矿测试, Rock and Mineral Analysis], V30, P521
[3]  
[包志安 BAO Zhian], 2011, [地球化学, Geochimica], V40, P223
[4]   Applications of accurate, high-precision Pb isotope ratio measurement by multi-collector ICP-MS [J].
Collerson, KD ;
Kamber, BS ;
Schoenberg, R .
CHEMICAL GEOLOGY, 2002, 188 (1-2) :65-83
[5]   Laser ablation ICP-MS analysis of geological materials prepared as lithium bordte glasses [J].
Eggins, SM .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2003, 27 (02) :147-162
[6]   Sr and Pb isotopic composition of five USGS glasses (BHVO-2G, BIR-1G, BCR-2G, TB-1G, NKT-1G) [J].
Elburg, M ;
Vroon, P ;
van der Wagt, B ;
Tchalikian, A .
CHEMICAL GEOLOGY, 2005, 223 (04) :196-207
[7]  
Galer S.J.G., 1998, Mineralogical Magazine, V62A, P491, DOI DOI 10.1180/MINMAG.1998.62A.1.260
[8]   Nano-particulate pressed powder tablets for LA-ICP-MS [J].
Garbe-Schoenberg, Dieter ;
Mueller, Samuel .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (06) :990-1000
[9]   Obsidian characterization by laser ablation ICP-MS and its application to prehistoric trade in the Mediterranean and the Near East: Sources and distribution of obsidian within the Aegean and Anatolia [J].
Gratuze, B .
JOURNAL OF ARCHAEOLOGICAL SCIENCE, 1999, 26 (08) :869-881
[10]   Trace element fingerprinting of australian ocher using laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS) for the provenance establishment and authentication of indigenous art [J].
Green, Rachel L. ;
Watling, R. John .