Accuracy of an unattended home CPAP titration in the treatment of obstructive sleep apnea

被引:58
作者
Sériès, F
机构
[1] Hop Laval, Ctr Pneumol, Unite Rech, Ste Foy, PQ G1V 4G5, Canada
[2] Univ Laval, Quebec City, PQ, Canada
关键词
D O I
10.1164/ajrccm.162.1.9908023
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Treatment of sleep apnea-hypopnea syndrome (SAHS) by fixed continuous positive airway pressure (CPAP) requires an in-laboratory titration procedure to determine the effective pressure level (Peff), We recently reported that one auto-CPAP machine can be used without titration study allowing Peff determination. The aim of this study was to evaluate the accuracy of an auto CPAP trial at home. A 1- or 2-wk automatic CPAP trial was done at home in 40 patients by estimating the reference pressure (Pref) to be set and a Pref + 3 cm H2O/-4 cm H2O pressure interval. Peff was then determined according to the percentage of CPAP time that was spent less than or equal to Pref. This Peff value was set on a fixed CPAP machine for two additional weeks and a control sleep study was done. The pressure setting on fixed CPAP had to be increased by 1 +/- 1 cm H2O (mean +/- SD) above estimated Pref. Sleep improved with fixed CPAP, with a normalization of the apnea + hypopnea index (AHI) in 38 of 40 and resumption of diurnal hypersomnolence. CPAP compliance remained excellent (CPAP use: 6.1 +/- 1.7 h/night) after 6.5 +/- 2.8 mo of CPAP treatment. These results indicate that auto-CPAP therapy represents a new useful and accurate way to identify conventional CPAP setting outside hospital and sleep laboratories.
引用
收藏
页码:94 / 97
页数:4
相关论文
共 19 条
[1]  
[Anonymous], 1992, SLEEP, V15, P174
[2]  
BEHDEHANI K, 1998, SLEEP, V21, P485
[3]   Two months follow up of auto-CPAP treatment in patients with obstructive sleep apnoea [J].
Boudewyns, A ;
Grillier-Lanoir, V ;
Willemen, MJ ;
De Cock, WA ;
Van de Heyning, PH ;
De Backer, WA .
THORAX, 1999, 54 (02) :147-149
[4]   Evaluation of an auto-CPAP device for treatment of obstructive sleep apnoea [J].
Ficker, JH ;
Wiest, GH ;
Lehnert, G ;
Wiest, B ;
Hahn, EG .
THORAX, 1998, 53 (08) :643-648
[5]   MORTALITY AND APNEA INDEX IN OBSTRUCTIVE SLEEP-APNEA - EXPERIENCE IN 385 MALE-PATIENTS [J].
HE, J ;
KRYGER, MH ;
ZORICK, FJ ;
CONWAY, W ;
ROTH, T .
CHEST, 1988, 94 (01) :9-14
[6]   DAYTIME SLEEPINESS, SNORING, AND OBSTRUCTIVE SLEEP-APNEA - THE EPWORTH SLEEPINESS SCALE [J].
JOHNS, MW .
CHEST, 1993, 103 (01) :30-36
[7]   Influence of nasal obstruction on auto-CPAP behaviour during sleep in sleep apnoea/hypopnoea syndrome [J].
Lafond, C ;
Sériès, F .
THORAX, 1998, 53 (09) :780-783
[8]   Comparison of manual and automatic CPAP titration in patients with sleep apnea/hypopnea syndrome [J].
Lloberes, P ;
Ballester, E ;
Montserrat, JM ;
Botifoll, E ;
Ramirez, A ;
Reolid, A ;
Gistau, C ;
RodriguezRoisin, R .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (06) :1755-1758
[9]   Efficacy of auto-CPAP in the treatment of obstructive sleep apnea/hypopnea syndrome [J].
Meurice, JC ;
Marc, I ;
Series, F .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 153 (02) :794-798
[10]   Effects of mouth opening on upper airway collapsibility in normal sleeping subjects [J].
Meurice, JC ;
Marc, I ;
Carrier, G ;
Series, F .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 153 (01) :255-259