Numerical analysis of effective thermal conductivity with thermal conduction and radiation in packed beds

被引:9
作者
Asakuma, Yusuke [1 ]
Honda, Itsuro [1 ]
Yamamoto, Tsuyoshi [2 ]
机构
[1] Univ Hyogo, Dept Chem Engn, 2167 Shosha, Himeji, Hyogo 6712280, Japan
[2] Kyushu Univ, Dept Chem Engn, Nishi Ku, 744 Motooka, Fukuoka 8190395, Japan
关键词
Effective thermal conductivity; Homogenization method; Biot number; Packed bed; HYDROGEN-PRODUCTION; CONTACT RESISTANCE; REACTORS;
D O I
10.1016/j.ijheatmasstransfer.2017.06.083
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermal radiation in a packed bed is controlled by temperature, emissivity, particle size, and bed structure, including void fraction, particle configuration, and the number of contact points. Thus, thermal radiation plays an important role in higher temperature operation of bed reactors. In this study, effect of the radiation/conduction ratio, namely, the Biot number with a thermal radiation coefficient, on effective thermal conductivity was investigated to clarify heat transfer in a packed bed. The Biot number for thermal radiation was defined as a function of temperature, particle size, emissivity, and configuration factor. The results obtained by the homogenization method showed that effective thermal conductivity with thermal radiation is simplified by the Biot number. Finally, the behavior of thermal radiation in the packed bed can be expressed by a sigmoidal function with the Biot number, even though the bed structure is complex. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:402 / 406
页数:5
相关论文
共 19 条
[1]   Homogenization method for effective thermal conductivity of metal hydride bed [J].
Asakuma, Y ;
Miyauchi, S ;
Yamamoto, T ;
Aoki, H ;
Miura, T .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2004, 29 (02) :209-216
[2]   Thermal analysis with contact resistance of packed bed by a homogenization method [J].
Asakuma, Yusuke ;
Asada, Masahiro ;
Kanazawa, Yushin ;
Yamamoto, Tsuyoshi .
POWDER TECHNOLOGY, 2016, 291 :46-51
[3]   Thermal radiation analysis of packed bed by a homogenization method [J].
Asakuma, Yusuke ;
Kanazawa, Yushin ;
Yamamoto, Tsuyoshi .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 73 :97-102
[4]   Digital image correlation and finite element analysis of inter- and intra-granular deformation [J].
Dave, S. ;
Song, X. ;
Hofmann, F. ;
Dragnevski, K. ;
Korsunsky, A. M. .
MESOMECHANICS 2009, 2009, 1 (01) :197-200
[5]   Simulation of hydrogen production through chemical looping reforming process in a packed-bed reactor [J].
Diglio, Giuseppe ;
Bareschino, Piero ;
Mancusi, Erasmo ;
Pepe, Francesco .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2016, 105 :137-151
[6]  
Dixon A. G., 2014, P 2014 COMSOL
[7]   The effect of thermal contact resistance on heat management in the electronic packaging [J].
Grujicic, M ;
Zhao, CL ;
Dusel, EC .
APPLIED SURFACE SCIENCE, 2005, 246 (1-3) :290-302
[8]   Prediction of the effective thermal conductivity of powder insulation [J].
Jin, Lingxue ;
Park, Jiho ;
Lee, Cheonkyu ;
Jeong, Sangkwon .
PROCEEDINGS OF THE 25TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2014, 2015, 67 :970-975
[9]   X-ray computed tomography of packed bed chromatography columns for three dimensional imaging and analysis [J].
Johnson, T. F. ;
Levison, P. R. ;
Shearing, P. R. ;
Bracewella, D. G. .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1487 :108-115
[10]   Fermentative hydrogen production in packed-bed and packing-free upflow reactors [J].
Li, C. ;
Zhang, T. ;
Fang, H. H. P. .
WATER SCIENCE AND TECHNOLOGY, 2006, 54 (09) :95-103