Endovascular placement of a ventriculoatrial shunt - Technical note

被引:13
|
作者
Gonzalez, L. Fernando [1 ]
Kim, Louis [1 ]
Rekate, Harold L. [1 ]
McDougall, Cameron G. [1 ]
Albuquerque, Felipe C. [1 ]
机构
[1] St Josephs Hosp, Barrow Neurol Inst, Div Neurol Surg, Phoenix, AZ 85013 USA
关键词
cerebrospinal fluid; venography; endoscopy; ventriculoatrial shunt; pediatric neurosurgery;
D O I
10.3171/ped.2007.106.4.319
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Atrial shunt revision surgeries are sometimes difficult due to venous occlusion and neck scarring. A direct approach Guided by venography facilitates exposure and guarantees accurate placement of the distal catheter. Five patients with complicated histories of shunt malfunction were treated using an endoscope-assisted technique. The distal end of an atrial catheter was advanced into the atrium after having been connected to a venous catheter of a slightly smaller diameter than the one previously advanced from the femoral vein through the atrium. Once the position of the atrial catheter was confirmed fluoroscopically, the venous catheter was detached and removed. No complications developed in any patient. This endoscope-assisted technique offers three advantages: it demonstrates the patency of the jugular vein through venography, facilitates identification of the internal jugular vein in the neck, and provides a quick way to confirm that the distal end of the atrial catheter has been placed correctly. This technique should be considered for use in patients with a history of failed atrial shunts.
引用
收藏
页码:319 / 321
页数:3
相关论文
共 50 条
  • [1] Transfemoral vein placement of a ventriculoatrial shunt - Technical note
    Tubbs, R. Shane
    Barnhart, Douglas
    Acakpo-Satchivi, Leslie
    JOURNAL OF NEUROSURGERY, 2007, 106 (01) : 68 - 69
  • [2] Echocardiographic placement of cardiac tube in ventriculoatrial shunt - Technical note
    Szczerbicki, MR
    Michalak, M
    JOURNAL OF NEUROSURGERY, 1996, 85 (04) : 723 - 724
  • [3] Direct Cardiac Ventriculoatrial Shunt: Technical Note
    Heuer, Gregory G.
    Ranalli, Nathan J.
    Pisapia, Jared
    Storm, Phillip B.
    Gruber, Peter J.
    Sutton, Leslie N.
    PEDIATRIC NEUROSURGERY, 2012, 48 (02) : 118 - 121
  • [4] ACCURATE PLACEMENT OF THE ATRIAL CATHETER IN VENTRICULOATRIAL SHUNTS - TECHNICAL NOTE
    THOMPSON, DNP
    CASEY, AT
    HAYWARD, RD
    HARKNESS, WF
    JOURNAL OF NEUROSURGERY, 1995, 82 (01) : 140 - 141
  • [5] Ventriculoatrial Shunt Under Locoregional Anesthesia: A Technical Note
    Aspide, Raffaele
    Migliorino, Ernesto
    Pirina, Alessandro
    Berselli, Bruno
    Manet, Romain
    Goutagny, Stephane
    Castioni, Carlo Alberto
    Palandri, Giorgio
    WORLD NEUROSURGERY, 2022, 166 : 135 - 140
  • [6] Minimally invasive echo-guided placement of the cardiac tube in a ventriculoatrial shunt during pregnancy: Technical note
    Di Muro, Licia
    Pallini, Roberto
    Pietrini, Domenico
    Colizzi, Christian
    Denaro, Luca
    NEUROSURGERY, 2007, 61 (05) : 398 - 398
  • [7] Accurate placement of the distal end of a ventriculoatrial shunt with the aid of real-time transesophageal echocardiography - Technical note
    Machinis, Theofilos G.
    Fountas, Kostas N.
    Hudson, John
    Robinson, Joe Sam
    Troup, E. Christopher
    JOURNAL OF NEUROSURGERY, 2006, 105 (01) : 153 - 156
  • [8] A new method for inserting the atrial end of a ventriculoatrial shunt - Technical note
    Harrison, MJ
    Welling, BG
    DuBois, JJ
    JOURNAL OF NEUROSURGERY, 1996, 84 (04) : 705 - 707
  • [9] Port-a-cath and ventriculoatrial shunt at the same atrium: technical note
    Ezgu, Mehmet Can
    Kural, Cahit
    Guler, Salih
    Izci, Yusuf
    CHILDS NERVOUS SYSTEM, 2019, 35 (05) : 857 - 860
  • [10] Port-a-cath and ventriculoatrial shunt at the same atrium: technical note
    Mehmet Can Ezgu
    Cahit Kural
    Salih Guler
    Yusuf Izci
    Child's Nervous System, 2019, 35 : 857 - 860