Bilateral simultaneous metal inlay dissociation from the polyethylene liner of a metal-on-metal hip replacement

被引:6
|
作者
Girard, J. [1 ]
Soenen, M. [1 ]
Monnin, C. [2 ]
Migaud, H. [1 ]
机构
[1] Univ Lille 2, Dept Orthopaed C, Roger Salengro Hosp, Lille Univ Teaching Hosp Ctr, F-59037 Lille, France
[2] Private Hosp Bois, F-59000 Lille, France
关键词
Total hip arthroplasty; Composite polyethylene liner failure; Prosthetic components dissociation; THR mechanical failure; FOLLOW-UP; ARTHROPLASTY; FRACTURE;
D O I
10.1016/j.otsr.2009.07.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Hard-on-hard bearings for total hip replacement may require a modular acetabular inlay for which polyethylene is often used in a sandwich-type configuration. However, differences in the elastic modulus of the materials make fixation of this metal insert uncertain. The aim of this study is to report a case of bilateral separation of the metal insert from the polyethylene sandwich in a metal-on-metal bearings prosthesis. Materials and methods: A bilateral total hip arthroplasty was performed in two operations, four months apart, in a 53-year-old woman following a corticosteroid-induced osteonecrosis. The total hip replacement system included a cementless stem, and a press-fit hemispheric cup containing a polyethylene sandwich with a metallic insert (Sikomet (TM)). Results: Three years later, the patient consulted because of abnormal noise in her right hip which appeared normal on conventional X-ray. Three months later she consulted again for persistent noise. Separation of the metal insert from the polyethylene sandwich was diagnosed and an acetabular revision was performed selecting a metal-on-polyethylene articulation system. The postoperative course, for this revision, was uneventful, but the patient returned with the similar symptoms in her left hip four months later, resulting in the same type of revision. During the revisions, osteolysis secondary to metallosis was diagnosed, requiring synovectomy and acetabular reconstruction with morcelized allograft impaction. The left side postoperative course included three dislocations in nine months which were conservatively treated and have not since recurred. Discussion and conclusion: This is the first reported case recording an almost simultaneous bilateral dissociation of a hard-on-hard inlay from its polyethylene sandwich. This bilateral case suggests that the fixation of the metal insert inside the polyethylene was probably defective. This case is also a reminder that mechanical complications (separation, implant fracture) should be searched for in presence of any abnormal noise occurring after hard-on-hard bearings prosthetic implantation. This confirms the necessity of periodical follow-up of hip arthroplasties and the importance of knowing their radiological features. The low carbon content of the Sikomet (TM) bearing may have been the cause of this failure by increasing frictional torque on the bearing surface, causing metallosis which has already been described in the literature in this type of hip replacement system. (c) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:443 / 446
页数:4
相关论文
共 50 条
  • [31] Metal-on-metal hip resurfacing
    Ebied, A
    Journeaux, S
    CURRENT ORTHOPAEDICS, 2002, 16 (06): : 420 - 425
  • [32] Migration of metal-on-metal versus ceramic-on-polyethylene hip prostheses
    Pabinger, C
    Biedermann, R
    Stöckl, B
    Fischer, M
    Krismer, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (412) : 103 - 110
  • [33] Metal-on-metal versus polyethylene in hip arthroplasty: A randomized clinical trial
    MacDonald, SJ
    McCalden, RW
    Chess, DG
    Bourne, RB
    Rorabeck, CH
    Cleland, A
    Leung, F
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (406) : 282 - 296
  • [34] Bilateral total hip replacement: periprosthetic pseudotumor collections are more prevalent in metal-on-metal implants compared to non-metal-on-metal ones
    Slonimsky, Einat
    Kushnir, Tammar
    Kadar, Assaf
    Menahem, Aharon
    Grundshtein, Alon
    Dekel, Shmuel
    Eshed, Iris
    ACTA RADIOLOGICA, 2016, 57 (04) : 463 - 467
  • [35] Repeated metal ion measurements in patients with high risk metal-on-metal hip replacement
    Reito, Aleksi
    Moilanen, Teemu
    Puolakka, Timo
    Pajamaki, Jorma
    Eskelinen, Antti
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (07) : 1353 - 1361
  • [36] Repeated metal ion measurements in patients with high risk metal-on-metal hip replacement
    Aleksi Reito
    Teemu Moilanen
    Timo Puolakka
    Jorma Pajamäki
    Antti Eskelinen
    International Orthopaedics, 2014, 38 : 1353 - 1361
  • [37] Metal-on-metal total hip replacement - What does the literature say?
    Dumbleton, JH
    Manley, MT
    JOURNAL OF ARTHROPLASTY, 2005, 20 (02): : 174 - 188
  • [38] Wear of ceramic coated metal-on-metal bearings used for hip replacement
    Gispert, M. P.
    Serro, A. P.
    Colaco, R.
    Pires, E.
    Saramago, B.
    WEAR, 2007, 263 : 1060 - 1065
  • [39] Predictive role of the Λ ratio in the evaluation of metal-on-metal total hip replacement
    Affatato, S.
    Spinelli, M.
    Zavalloni, M.
    Leardini, W.
    Viceconti, M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H5) : 617 - 628
  • [40] Magnetic resonance imaging of painful metal-on-metal total hip replacement
    Nikolaou V.S.
    Petit A.
    Khoury V.
    Blain-Pare E.
    Zukor D.J.
    Huk O.L.
    Antoniou J.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (2) : 313 - 319