Segmental quantitative myocardial perfusion with PET for the detection of significant coronary artery disease in patients with stable angina

被引:19
|
作者
Berti, Valentina [1 ]
Sciagra, Roberto [1 ]
Neglia, Danilo [2 ]
Pietila, Mikko [3 ,4 ,5 ]
Scholte, Arthur J. [6 ]
Nekolla, Stephan [7 ]
Rouzet, Francois [8 ]
Pupi, Alberto [1 ]
Knuuti, Juhani [3 ,4 ,5 ]
机构
[1] Univ Florence, Dept Biomed Expt & Clin Sci Mario Serio, Nucl Med Unit, Largo Brambilla 3, I-50134 Florence, Italy
[2] CNR, Inst Clin Physiol, Via Savi 8, I-56100 Pisa, Italy
[3] Univ Turku, Ctr Heart, Turku, Finland
[4] Univ Turku, Turku PET Ctr, Turku, Finland
[5] Turku Univ Hosp, FIN-20520 Turku, Finland
[6] Leiden Univ, Med Ctr, Dept Cardiol, Leiden, Netherlands
[7] Tech Univ Munich, Nukl Med Klin, D-80290 Munich, Germany
[8] Univ Paris Diderot, Bichat Univ Hosp, Dept Nucl Med, Paris, France
基金
芬兰科学院;
关键词
Myocardial perfusion imaging; Cardiac PET; Absolute quantification; Reproducibility; Accuracy; POSITRON-EMISSION-TOMOGRAPHY; AMERICAN-HEART-ASSOCIATION; BLOOD-FLOW; RB-82; PET; STENOSIS SEVERITY; PHYSIOLOGICAL ASSESSMENT; DIAGNOSTIC-ACCURACY; CLINICAL CARDIOLOGY; N-13; AMMONIA; QUANTIFICATION;
D O I
10.1007/s00259-016-3362-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The goal of this study is to determine the technical accuracy of segmental perfusion parameters assessed with quantitative cardiac PET imaging in the evaluation of coronary artery disease (CAD) in patients with stable angina. A cohort of patients who participated in the EVINCI protocol underwent an evaluation of coronary anatomy by invasive coronary angiography (ICA) and/or coronary computed tomography angiography (CCTA) and PET myocardial perfusion imaging with H-2 O-15, (NH3)-N-13 or Rb-82. PET studies were analyzed by two independent observers blinded to clinical and instrumental data, and classified as positive or negative for significant CAD using only segmental perfusion measurements and cut-off values from literature. On a per-patient basis, the overall inter-observer agreement on PET results was 90 % (kappa = 0.79), indicating substantial agreement. On a per-vessel basis, the inter-observer agreement on PET results was 88 % (kappa = 0.74) in the RCA territory, 94 % (kappa = 0.84) in the LAD territory and 94 % (kappa = 0.85) in the LCX territory. Segmental PET measurements correctly identified 85 % of the patients, resulting in a global sensitivity of 86 %, a specificity of 84 %, a positive predictive value (PPV) of 69 % and a negative predictive value (NPV) of 93 %. In vessel-based analyses, quantitative perfusion parameters had a sensitivity, specificity, PPV and NPV of 92 %, 82 %, 42 % and 99 %, respectively, for the detection of significant coronary stenoses in all major coronary arteries. The assessment of absolute myocardial perfusion parameters measured at a segment level lead to reliable and accurate identification of patients with significant coronary stenosis at ICA and/or CCTA.
引用
收藏
页码:1522 / 1529
页数:8
相关论文
共 50 条
  • [1] Segmental quantitative myocardial perfusion with PET for the detection of significant coronary artery disease in patients with stable angina
    Valentina Berti
    Roberto Sciagrà
    Danilo Neglia
    Mikko Pietilä
    Arthur J. Scholte
    Stephan Nekolla
    François Rouzet
    Alberto Pupi
    Juhani Knuuti
    European Journal of Nuclear Medicine and Molecular Imaging, 2016, 43 : 1522 - 1529
  • [2] Quantitative Assessment of Myocardial Perfusion in the Detection of Significant Coronary Artery Disease Cutoff Values and Diagnostic Accuracy of Quantitative [15O]H2O PET Imaging
    Danad, Ibrahim
    Uusitalo, Valtteri
    Kero, Tanja
    Saraste, Antti
    Raijmakers, Pieter G.
    Lammertsma, Adriaan A.
    Heymans, Martijn W.
    Kajander, Sami A.
    Pietilae, Mikko
    James, Stefan
    Soerensen, Jens
    Knaapen, Paul
    Knuuti, Juhani
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (14) : 1464 - 1475
  • [3] Dynamic Myocardial Perfusion CT for the Detection of Hemodynamically Significant Coronary Artery Disease
    Nous, Fay M. A.
    Geisler, Tobias
    Kruk, Mariusz B. P.
    Alkadhi, Hatem
    Kitagawa, Kakuya
    Vliegenthart, Rozemarijn
    Hell, Michaela M.
    Hausleiter, Jorg
    Nguyen, Patricia K.
    Budde, Ricardo P. J.
    Nikolaou, Konstantin
    Kepka, Cezary
    Manka, Robert
    Sakuma, Hajime
    Malik, Sachin B.
    Coenen, Adriaan
    Zijlstra, Felix
    Klotz, Ernst
    van der Harst, Pim
    Artzner, Christoph
    Dedic, Admir
    Pugliese, Francesca
    Bamberg, Fabian
    Nieman, Koen
    JACC-CARDIOVASCULAR IMAGING, 2022, 15 (01) : 75 - 87
  • [4] Myocardial perfusion PET/CT to evaluate known and suspected coronary artery disease
    Naya, M.
    Di Carli, M. F.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 54 (02) : 145 - 156
  • [5] Improved diagnostic accuracy for coronary artery disease detection with quantitative 3D 82Rb PET myocardial perfusion imaging
    Renaud, Jennifer M.
    Poitrasson-Riviere, Alexis
    Moody, Jonathan B.
    Hagio, Tomoe
    Ficaro, Edward P.
    Murthy, Venkatesh L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 51 (01) : 147 - 158
  • [6] Comparison of two dipyridamole infusion protocols for myocardial perfusion imaging in subjects with low likelihood of significant obstructive coronary artery disease
    Harel, Francois
    Finnerty, Vincent
    Authier, Sebastien
    Pelletier-Galarneau, Matthieu
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (05) : 1820 - 1828
  • [7] Comparison of Dual to Single Contrast Bolus Magnetic Resonance Myocardial Perfusion Imaging for Detection of Significant Coronary Artery Disease
    Groothuis, Jan G. J.
    Kremers, Frans P. P. J.
    Beek, Aernout M.
    Brinckman, Stijn L.
    Tuinenburg, Alvin C.
    Jerosch-Herold, Michael
    van Rossum, Albert C.
    Hofman, Mark B. M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (01) : 88 - 93
  • [8] Quantitative myocardial perfusion response to adenosine and regadenoson in patients with suspected coronary artery disease
    Kero, Tanja
    Saraste, Antti
    Lagerqvist, Bo
    Sorensen, Jens
    Pikkarainen, Essi
    Lubberink, Mark
    Knuuti, Juhani
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (01) : 24 - 36
  • [9] Absolute flow ormyocardial flow reserve for the detection of significant coronary artery disease?
    Joutsiniemi, Esa
    Saraste, Antti
    Pietila, Mikko
    Maki, Maija
    Kajander, Sami
    Ukkonen, Heikki
    Airaksinen, Juhani
    Knuuti, Juhani
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (06) : 659 - 665
  • [10] Quantification of Absolute Myocardial Perfusion in Patients With Coronary Artery Disease
    Morton, Geraint
    Chiribiri, Amedeo
    Ishida, Masaki
    Hussain, Shazia T.
    Schuster, Andreas
    Indermuehle, Andreas
    Perera, Divaka
    Knuuti, Juhani
    Baker, Stacey
    Hedstroem, Erik
    Schleyer, Paul
    O'Doherty, Michael
    Barrington, Sally
    Nagel, Eike
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (16) : 1546 - 1555