High-temperature ampacity model for overhead conductors

被引:20
|
作者
Chen, SL [1 ]
Black, WZ
Loard, HW
机构
[1] Cordis Corp, Miami Lakes, FL 33014 USA
[2] Georgia Inst Technol, Sch Mech Engn, Atlanta, GA 30332 USA
[3] Georgia Power Co, Line Design, Atlanta, GA 30297 USA
关键词
ampacity; heat transfer; high-temperature operation; overhead lines;
D O I
10.1109/TPWRD.2002.804003
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A computer-based ampacity model that can predict the temperature of overhead conductors for temperatures as high as 250 degreesC has been developed. The model is a revision of a program that has been reliably used for approximately 20 years to calculate the transient ampacity of a wide variety of conductor designs. The accuracy of the program has been determined by comparing the program predictions with temperatures that are measured on a full-scale energized outdoor test span. The accuracy of the program decreases as the average conductor temperature increases. As the conductor temperature increases, the spatial variations, both azimuthal and radial, are magnified and the task of calculating a single, average conductor temperature becomes more challenging. Typical variations in the conductor temperature were as high as 65 degreesC in a single span when the conductor temperature approached 250 degreesC. These temperature variations create difficulties when trying to either measure the conductor temperature with hardware attached to the line or predict the temperature with a computer-based ampacity model.
引用
收藏
页码:1136 / 1141
页数:6
相关论文
共 50 条
  • [41] A Dynamic Tanks-in-Series Model for a High-Temperature PEM Fuel Cell
    Danilov, Valery A.
    Kolb, Gunther
    Cremers, Carsten
    ENERGIES, 2024, 17 (12)
  • [42] High-temperature effects on the mucus layers in a realistic human upper airway model
    Kulkarni, Nilay Atul
    Kleinstreuer, Clement
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 163
  • [43] The high temperature cable solution for electrical overhead distribution lines
    Landeira, Marta
    Mazon, Angel Javier
    Morentin, Patxi
    Albizu, Igor
    DYNA, 2007, 82 (05): : 226 - 230
  • [44] Human thermoregulatory model for simulating thermal response in high-temperature and hypobaric environments
    Zhang, Qing
    Ding, Li
    Xu, Ruiqi
    Feng, Hetian
    Liu, Chengyi
    Zhou, Shengjun
    Nie, Jiachen
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 52
  • [45] APPLICATION OF A LINE AMPACITY MODEL AND ITS USE IN TRANSMISSION LINES OPERATIONS
    Snajdr, Jaroslav
    Sedlacek, Jan
    Vostracky, Zdenek
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2014, 65 (04): : 221 - 227
  • [46] High-Temperature Perovskite Solar Cells
    Dong, Zijing
    Li, Weiping
    Wang, Hailiang
    Jiang, Xiaoyu
    Liu, Huicong
    Zhu, Liqun
    Chen, Haining
    SOLAR RRL, 2021, 5 (09):
  • [47] Factors influencing ampacity and temperature of underground power cables
    Metwally, I. A.
    Al-Badi, A. H.
    Al Farsi, A. S.
    ELECTRICAL ENGINEERING, 2013, 95 (04) : 383 - 392
  • [48] Factors influencing ampacity and temperature of underground power cables
    I. A. Metwally
    A. H. Al-Badi
    A. S. Al Farsi
    Electrical Engineering, 2013, 95 : 383 - 392
  • [49] ALUMINUM-ALLOY CONDUCTORS FOR AC TRACTION OVERHEAD EQUIPMENT
    MUKERJEE, MN
    SANKARANARAYANAN, CA
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1979, 126 (07): : 665 - 669
  • [50] Analysis of High Temperature Low Sag Conductors used for High Voltage Transmission
    Reddy, Subba B.
    Chatterjee, Diptendu
    5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESEARCH (ICAER) 2015, 2016, 90 : 179 - 184