Underfilling of vacuum blood collection tubes leads to increased lactate dehydrogenase activity in serum and heparin plasma samples

被引:5
作者
Neuwinger, Nick [1 ,2 ,3 ,4 ,5 ]
zum Bueschenfelde, Dirk Meyer [1 ,2 ,3 ,4 ,5 ]
Tauber, Rudolf [1 ,2 ,3 ,4 ,5 ]
Kappert, Kai [1 ,2 ,3 ,4 ,5 ]
机构
[1] Charite Univ Med Berlin, Augustenburger Pl 1, D-13353 Berlin, Germany
[2] Free Univ Berlin, Augustenburger Pl 1, D-13353 Berlin, Germany
[3] Humboldt Univ, Augustenburger Pl 1, D-13353 Berlin, Germany
[4] Berlin Inst Hlth, Inst Lab Med Clin Chem & Pathobiochem, Augustenburger Pl 1, D-13353 Berlin, Germany
[5] Lab Berlin Charite Vivantes GmbH, Berlin, Germany
关键词
hemolysis; lactate dehydrogenase; preanalytical phase; reference limits; underfilling; venipuncture; CATALYTIC-ACTIVITY CONCENTRATIONS; ANALYTES; ENZYMES;
D O I
10.1515/cclm-2019-0616
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Lactate dehydrogenase (LD) activity is routinely monitored for therapeutic risk stratification of malignant diseases, but is also prone to preanalytical influences. Methods: We systematically analyzed the impact of defined preanalytical conditions on the hemolysis-susceptible parameters LD, potassium (K) and hemolysis index in vacuum blood collection tubes (serum [SE], heparin plasma [HP]). Blood was collected by venipuncture from healthy volunteers. Tubes were either filled or underfilled to approximately 50%, then processed directly or stored at room temperature for 4 h. Potassium (K), sodium (Na), chloride (Cl), LD, creatine kinase (CK), total cholesterol, and indices for hemolysis, icterus, and lipemia were analyzed. Filling velocity was determined in a subset of tubes. Findings in healthy volunteers were reconfirmed in an inpatient cohort (n = 74,751) that was analyzed for plasma yield and LD data distribution. Results: LD activity was higher in HP compared to SE. Underfilling led to higher LD values (SE: +21.6%; HP: +28.3%), K (SE: +4.2%; HP: +5.3%), and hemolysis index (SE: +260.8%; HP: +210.0%), while other analytes remained largely unchanged. Filling velocity of tubes was approximately 3-fold higher in the first half compared to the second half in both HP and SE collection tubes. Importantly, plasma yield also inversely correlated with LD in routine patients. By calculating reference limits, the lowest plasma yield quartile of the patient cohort displayed LD values clearly exceeding current reference recommendations. Conclusions: Underfilling of tubes leads to a higher-proportion of blood aspirated with high velocity and relevant elevations in LD. This finding should be considered in cases of clinically implausible elevated LD activities.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 34 条
[1]  
[Anonymous], 2005, J Lab Med
[2]  
Arzideh F, 2007, CLIN CHEM LAB MED, V45, P1043, DOI 10.1515/CCLM.2007.250
[3]  
Boyanton BL, 2002, CLIN CHEM, V48, P2242
[4]   ON THE ORIGIN OF THE LACTATE-DEHYDROGENASE INDUCED RATE EFFECT [J].
BURGNER, JW ;
RAY, WJ .
BIOCHEMISTRY, 1984, 23 (16) :3636-3648
[5]   Biological Variation Estimates Obtained from 91 Healthy Study Participants for 9 Enzymes in Serum [J].
Carobene, Anna ;
Roraas, Thomas ;
Solvik, Una Orvim ;
Sylte, Marit Sverresdotter ;
Sandberg, Sverre ;
Guerra, Elena ;
Marino, Irene ;
Jonker, Niels ;
Barla, Gerhard ;
Bartlett, William A. ;
Fernandez-Calle, Pilar ;
Diaz-Garzon, Jorge ;
Tosato, Francesca ;
Plebani, Mario ;
Coskun, Abdurrahman ;
Serteser, Mustafa ;
Unsal, Ibrahim ;
Ceriottil, Ferruccio .
CLINICAL CHEMISTRY, 2017, 63 (06) :1141-1150
[6]   Errors in a stat laboratory: Types and frequencies 10 years later [J].
Carraro, Paolo ;
Plebani, Mario .
CLINICAL CHEMISTRY, 2007, 53 (07) :1338-1342
[7]   Evaluation of the Becton-Dickinson rapid serum tube: does it provide a suitable alternative to lithium heparin plasma tubes? [J].
Dimeski, Goce ;
Masci, Paul P. ;
Trabi, Manuela ;
Lavin, Martin F. ;
de Jersey, John .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (05) :651-657
[8]   Usefulness of lactate dehydrogenase and its isoenzymes as indicators of lung damage or inflammation [J].
Drent, M ;
Cobben, NAM ;
Henderson, RF ;
Wouters, EFM ;
vanDieijenVisser, M .
EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (08) :1736-1742
[9]   Stability of routine biochemical analytes in whole blood and plasma/serum: focus on potassium stability from lithium heparin [J].
Dupuy, Anne Marie ;
Cristol, Jean Paul ;
Vincent, Bruno ;
Bargnoux, Anne Sophie ;
Mendes, Mickael ;
Philibert, Pascal ;
Klouche, Kadda ;
Badiou, Stephanie .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (03) :413-421
[10]   Parameters for Validating a Hospital Pneumatic Tube System [J].
Farnsworth, Christopher W. ;
Webber, Daniel M. ;
Krekeler, James A. ;
Budelier, Melissa M. ;
Bartlett, Nancy L. ;
Gronowski, Ann M. .
CLINICAL CHEMISTRY, 2019, 65 (05) :694-702