Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients

被引:41
作者
Kok, Madeleine [1 ,2 ]
Mihl, Casper [1 ,2 ]
Hendriks, Babs M. F. [1 ]
Altintas, Sibel [2 ,3 ]
Kietselaer, Bas L. J. H. [1 ,2 ,3 ]
Wildberger, Joachim E. [1 ,2 ]
Das, Marco [1 ,2 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Radiol, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ, Med Ctr, Sch Cardiovasc Dis, CARIM, NL-6202 AZ Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Cardiol, NL-6202 AZ Maastricht, Netherlands
关键词
Multidetector-row computed tomography; Contrast media; Tube voltage; AFFIRMED ITERATIVE RECONSTRUCTION; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; FILTERED BACK-PROJECTION; RADIATION-DOSE REDUCTION; DUAL-SOURCE CT; IMAGE QUALITY; ABDOMINAL CT; OBESE-PATIENTS; CHEST CT; IODINE;
D O I
10.1016/j.ejrad.2016.03.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose was to investigate optimal contrast media (CM) injection parameters for lower kVp settings, whilst maintaining diagnostic attenuation levels. Methods and materials: First, a circulation phantom with physiological parameters (BP 120/80 mmHg, HR 60 bpm) was used. A fixed CM injection protocol was used for each kVp setting (300 mgI/m1 [Iopromide], volume =45 ml, flow rate = 6.0 ml/s, iodine delivery rate [IDR] = 1.8 gI/s, iodine load = 13.5 gI; at 120, 100, 80 and 70 kVp). Then, IDR was decreased by steps of 0.2 gI/s for each kVp setting, until diagnostically insufficient attenuation values were reached (<325 HU). In order to keep injection time constant (7.5 s), total iodine load (TIL) was reduced accordingly. Second, clinical applicability at 120 and 100 kVp was evaluated in patients (n = 60) referred for coronary CT angiography. A standard and reduced (12% less) CM protocol was used based on weight classes and scan duration (`high-pitch': 1 s; 'adaptive sequence' and 'helical': 7 s). Attenuation levels of the coronary arteries were measured and compared between protocols. Results: Using a fixed CM injection at each kVp level resulted in the following HU values: 335 HU +/- 31 (120 kVp); 425 HU +/- 30 (100 kVp); 587 HU +/- 29 (80 kVp); 666 HU +/- 27 (70 kVp). Keeping diagnostic enhancement levels (353 HU +/- 28) CM could be reduced as follows: 12% for 100 kVp; 45% for 80 kVp and 56% for 70 kVp. Diagnostic enhancement levels could be reproduced with concurrent CM reduction (-12% at 100 kV) in the clinical setting (382 HU +/- 35). Conclusion: CM injection parameters can be substantially reduced at low kVp settings (up to 56% at 70 kVp), whilst maintaining diagnostic attenuation levels. This may play an important role in CT imaging of the coronary arteries as well as cerebral and peripheral circulations in the future. (C) 2016 Published by Elsevier Ireland Ltd.
引用
收藏
页码:1068 / 1074
页数:7
相关论文
共 33 条
  • [1] Contrast-to-Noise Ratio and Low-Contrast Object Resolution on Full- and Low-Dose MDCT: SAFIRE Versus Filtered Back Projection in a Low-Contrast Object Phantom and in the Liver
    Baker, Mark E.
    Dong, Frank
    Primak, Andrew
    Obuchowski, Nancy A.
    Einstein, David
    Gandhi, Namita
    Herts, Brian R.
    Purysko, Andrei
    Remer, Erick
    Vachani, Neil
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (01) : 8 - 18
  • [2] Introduction of a dedicated circulation phantom for comprehensive in vitro analysis of intravascular contrast material application
    Behrendt, Florian F.
    Bruners, Philipp
    Kalafut, John
    Mahnken, Andreas H.
    Keil, Sebastian
    Plumhans, Cedric
    Das, Marco
    Stanzel, Sven
    Wildberger, Joachim E.
    Pfeffer, Jochen
    Guenther, Rolf W.
    Muehlenbruch, Georg
    [J]. INVESTIGATIVE RADIOLOGY, 2008, 43 (10) : 729 - 736
  • [3] Successful Dose Reduction Using Reduced Tube Voltage With Hybrid Iterative Reconstruction in Pediatric Abdominal CT
    Berlin, Sheila C.
    Weinert, Dayna M.
    Vasavada, Pauravi S.
    Martinez-Rios, Claudia
    Parikh, Roshni A.
    Wien, Michael A.
    Jordan, David W.
    Novak, Ronald D.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (02) : 392 - 399
  • [4] QUANTITATIVE THEORY OF HOUNSFIELD UNIT AND ITS APPLICATION TO DUAL ENERGY SCANNING
    BROOKS, RA
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (04) : 487 - 493
  • [5] Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography
    Cademartiri, Filippo
    Maffei, Erica
    Palumbo, Anselmo Alessandro
    Malago, Roberto
    La Grutta, Ludovico
    Meiijboom, W. Bob
    Aldrovandi, Annachiara
    Fusaro, Michele
    Vignali, Luigi
    Menozzi, Alberto
    Brambilla, Valerio
    Coruzzi, Paolo
    Midiri, Massimo
    Kirchin, Miles A.
    Mollet, Nico R. A.
    Krestin, Gabriel P.
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (03) : 576 - 583
  • [6] Cademartiri Filippo, 2006, AJR Am J Roentgenol, V187, pW430, DOI 10.2214/AJR.05.1406
  • [7] Radiation and contrast agent doses reductions by using 80-kV tube voltage in coronary computed tomographic angiography: A comparative study
    Cao, Jian-xin
    Wang, Yi-min
    Lu, Jin-guo
    Zhang, Yu
    Wang, Peng
    Yang, Cheng
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) : 309 - 314
  • [8] Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: Phantom study
    Funama, Y
    Awai, K
    Nakayama, Y
    Kakei, K
    Nagasue, N
    Shimamura, M
    Sato, N
    Sultana, S
    Morishita, S
    Yamashita, Y
    [J]. RADIOLOGY, 2005, 237 (03) : 905 - 910
  • [9] Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: Feasibility, image quality, radiation dose, and effect of iterative reconstruction
    Hell, Michaela M.
    Bittner, Daniel
    Schuhbaeck, Annika
    Muschiol, Gerd
    Brand, Michael
    Lell, Michael
    Uder, Michael
    Achenbach, Stephan
    Marwan, Mohamed
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (06) : 418 - 425
  • [10] Technique factors and image quality as functions of patient weight at abdominal CT
    Huda, W
    Scalzetti, EM
    Levin, G
    [J]. RADIOLOGY, 2000, 217 (02) : 430 - 435