Real-time and high-performance calibration method for high-speed swept-source optical coherence tomography

被引:14
|
作者
Azimi, Ehsan [1 ,2 ]
Liu, Bin [1 ,2 ]
Brezinski, Mark E. [1 ,2 ]
机构
[1] Brigham & Womens Hosp, Dept Orthoped Surg, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
基金
美国国家卫生研究院;
关键词
coherence; optical coherence tomography; algorithms; calibration; plaque rupture; arthritis; DOMAIN MODE-LOCKING; SEMICONDUCTOR-LASER; WAVELENGTH; BIOPSY; NM;
D O I
10.1117/1.3285660
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For high-speed swept-source optical coherence tomography (SS-OCT), the real-time calibration process to convert the OCT signal to wave number space is highly essential. A novel calibration process/algorithm using a genetic algorithm and precise interpolation is developed. This algorithm is embedded and validated in a SS-OCT system with 16-kHz A-scan rate. The performance of the new algorithm is evaluated by measuring point spread functions at two distinct locations in the entire imaging range. The data is compared to the same system but embedded with a regular calibration algorithm, which demonstrates about 20% improvement in the axial resolution. The steady improvement at different locations of the range suggests the strong robustness of the algorithm, which will ultimately optimize the operation performance of this SS-OCT system in terms of resolution and dynamic range and improves details in biological tissues. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3285660]
引用
收藏
页数:8
相关论文
共 50 条
  • [21] High-speed swept source optical coherence Doppler tomography for deep brain microvascular imaging
    Wei Chen
    Jiang You
    Xiaochun Gu
    Congwu Du
    Yingtian Pan
    Scientific Reports, 6
  • [22] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79
  • [23] High-speed swept source optical coherence Doppler tomography for deep brain microvascular imaging
    Chen, Wei
    You, Jiang
    Gu, Xiaochun
    Du, Congwu
    Pan, Yingtian
    SCIENTIFIC REPORTS, 2016, 6
  • [24] Comment on Real-Time In Vivo Assessment of Retinal Reattachment in Humans Using Swept-Source Optical Coherence Tomography
    Dell'Omo, Roberto
    Costagliola, Ciro
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 235 : 341 - 342
  • [25] High-speed wavelength-swept laser source with high-linearity sweep for optical coherence tomography
    Chong, Changho
    Morosawa, Atsushi
    Sakai, Tooru
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2008, 14 (01) : 235 - 242
  • [26] Real-time high-speed volumetric imaging using compressive sampling optical coherence tomography
    Young, Mei
    Lebed, Evgeniy
    Jian, Yifan
    Mackenzie, Paul J.
    Beg, Mirza Faisal
    Sarunic, Marinko V.
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (09): : 2690 - 2697
  • [27] High-speed cross-sectional imaging of valuable documents using common-path swept-source optical coherence tomography
    Fujiwara, Kazuo
    Matoba, Osamu
    APPLIED OPTICS, 2011, 50 (34) : H165 - H170
  • [28] Two-reference swept-source optical coherence tomography of high operation flexibility
    Chi, Ting-Ta
    Wu, Chiung-Ting
    Liao, Chen-Chin
    Tu, Yi-Chou
    Kiang, Yean-Woei
    Yang, C. C.
    OPTICS EXPRESS, 2012, 20 (27): : 28418 - 28430
  • [29] Ultrahigh-speed swept-source optical coherence tomography for macular optoretinography
    Ni, Shuibin
    Khan, Shanjida
    Jimenez-Villar, Alfonso
    Pennesi, Mark E.
    Bailey, Steven T.
    Huang, David
    Jian, Yifan
    Chen, Siyu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (09)
  • [30] Novel perspectives on swept-source optical coherence tomography
    Lavinsky F.
    Lavinsky D.