Comparative analysis of aneurysm volume by different methods based on angiography and computed tomography angiography

被引:10
作者
Escobar-de la Garma, Victor Hugo [1 ]
Zenteno, Marco [1 ]
Padilla-Vazquez, Felipe [1 ]
San-Juan, Daniel [2 ]
Ceron-Morales, Aurelio [1 ]
机构
[1] Inst Nacl Neurol & Neurocirugia Manuel Velasco Su, Neuroendovasc Therapy Dept, Ave Insurgentes Sur 3877, Mexico City 14269, DF, Mexico
[2] Inst Nacl Neurol & Neurocirugia Manuel Velasco Su, Dept Clin Res, Mexico City, DF, Mexico
关键词
Aneurysm; Volume; Digital subtraction angiography; Computed tomography; Packing density; Angiogram; DIGITAL-SUBTRACTION-ANGIOGRAPHY; INTRACRANIAL ANEURYSMS; CEREBRAL ANEURYSMS; MR-ANGIOGRAPHY; CT ANGIOGRAPHY; PACKING; COILS; APPROXIMATION;
D O I
10.1007/s10143-018-0943-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Endovascular treatment and prognosis of intracranial aneurysms are based on size and volume, which demand more accurate neuroimaging techniques. Aneurysm volume calculation is important to choose endovascular treatment modalities and packing density calculation. Of all these methods, it remains unknown which one is the most accurate to calculate aneurysm volume. The objective of this study is to compare the accuracy of three angiography-based versus three tomographic-based methods which calculate aneurysm volume. A retrospective study which included patients with ruptured and unruptured cerebral aneurysms diagnosed by angiogram and computed tomography angiography (CTA) was done. The accuracy of each method was assessed with an ellipsoid glass model of known volume, which helped us to adjust variation in volumetric measurements done with AngioSuite (c) and AngioCalc (c) softwares (based on angiographic and tomographic images), 3D-rotational angiography and 3D-CTA (tridimensional computed tomography angiography), based on measurements of diameters such as maximal width and maximal height. Descriptive statistics, ANOVA for repetitive samples and t test were used. We included 89 patients (126 saccular intracraneal aneurysms). AngioSuite (c) software (angiography-based) showed more accuracy compared to other methods in our control model. The geometric system (AngioCalc) based on CTA images was statistically different from all other methods studied. AngioCalc (CTA-based) demonstrated a significant difference compared with other methods hence, it may overestimate volume measurements. AngioSuite (c) software measurements (angiography-based) may be the most accurate method to calculate aneurysm volume.
引用
收藏
页码:1013 / 1019
页数:7
相关论文
共 50 条
  • [21] Computed Tomography Angiography of the Carotid and Cerebral Circulation
    Almandoz, Josser E. Delgado
    Romero, Javier M.
    Pomerantz, Stuart R.
    Lev, Michael H.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2010, 48 (02) : 265 - +
  • [22] Interrater Agreement in the Radiologic Characterization of Ruptured Intracranial Aneurysms Based on Computed Tomography Angiography
    Maldaner, Nicolai
    Stienen, Martin N.
    Bijlenga, Philippe
    Croci, Davide
    Zumofen, Daniel W.
    Dalonzo, Donato
    Marbacher, Serge
    Maduri, Rodolfo
    Daniel, Roy Thomas
    Serra, Carlo
    Esposito, Giuseppe
    Neidert, Marian Christoph
    Bozinov, Oliver
    Regli, Luca
    Burkhardt, Jan-Karl
    WORLD NEUROSURGERY, 2017, 103 : 876 - +
  • [23] Aneurysm re-rupture during computed tomography angiography
    Pérez-Núñez, A
    Alén, JF
    Ramos, A
    Millán, JM
    ACTA RADIOLOGICA, 2006, 47 (04) : 419 - 421
  • [24] Reproducibility of image-based computational models of intracranial aneurysm: a comparison between 3D rotational angiography, CT angiography and MR angiography
    Ren, Yuan
    Chen, Guo-Zhong
    Liu, Zhen
    Cai, Yan
    Lu, Guang-Ming
    Li, Zhi-Yong
    BIOMEDICAL ENGINEERING ONLINE, 2016, 15
  • [25] Comparative Analysis of 3-Dimensional Rotation Angiography versus 3-Dimensional Computed Tomography Angiography for Intracranial Aneurysm Treatment Detection and Planning
    Park, Jonathan
    Salamon, Noriko
    Duckwiler, Gary
    Vinuela, Fernando
    Sayer, James
    Villablanca, J. Pablo
    STROKE, 2013, 44 (02)
  • [26] Assessment of long-term results of intracranial aneurysm clipping by means of computed tomography angiography
    Kunert, Przemyslaw
    Prokopienko, Marek
    Gola, Magdalena
    Dziedzic, Tomasz
    Jaworski, Maciej
    Marchel, Andrzej
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2013, 47 (01) : 18 - 26
  • [27] Anatomical variations of the anterior cerebral arterial circle visualized by multidetector computed tomography angiography: Comparison with 3D rotational angiography
    Ferre, Jean-Christophe
    Niederberger, Emilie
    Morandi, Xavier
    Raoult, Helene
    Carsin-Nicol, Beatrice
    Gauvrit, Jean-Yves
    JOURNAL OF NEURORADIOLOGY, 2013, 40 (02) : 112 - 120
  • [28] Can Coronary Computed Tomography Angiography Replace Invasive Angiography? Coronary Computed Tomography Angiography Cannot Replace Invasive Angiography
    Stefanini, Giulio G.
    Windecker, Stephan
    CIRCULATION, 2015, 131 (04) : 418 - 426
  • [29] Renal imaging: duplex ultrasound, computed tomography angiography, magnetic resonance angiography, and angiography
    AbuRahma, Ali F.
    Yacoub, Michael
    SEMINARS IN VASCULAR SURGERY, 2013, 26 (04) : 134 - 143
  • [30] Comparison of Computed Tomography Angiography With Digital Subtraction Angiography in the Assessment of Clipped Intracranial Aneurysms
    Bharatha, Aditya
    Yeung, Robert
    Durant, Dean
    Fox, Allan J.
    Aviv, Richard I.
    Howard, Peter
    Thompson, Andrew L.
    Bartlett, Eric S.
    Symons, Sean P.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (03) : 440 - 445