Ultrasound-guided needle release of A1 pulley combined with corticosteroid injection is more effective than ultrasound-guided needle release alone in the treatment of trigger finger

被引:3
|
作者
Wu, Yan-Yan
Chen, Kai
He, Fan-Ding
Quan, Jie-Rong
Guo, Xuan-Yan [1 ]
机构
[1] Univ Elect Sci Technol China, Sichuan Acad Med Sci, Sch Med, Dept Ultrason, 32 West Second Sect,First Ring Rd, Chengdu 610072, Sichuan, Peoples R China
关键词
A1; pulley; Corticosteroid injection; Trigger finger; Ultrasonography-guided release;
D O I
10.1186/s12893-022-01665-1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The purpose of the present study was to evaluate the clinical effectiveness of ultrasonography-guided needle release of A1 pulley combined with corticosteroid injection by comparing it with ultrasound-guided needle release of the A1 pulley alone. Methods A total of 49 patients (55 fingers, thumb) with trigger fingers were included in this retrospective study. Twenty-seven fingers were treated with ultrasound-guided needle release of the A1 pulley alone (monotherapy group), and 28 fingers were treated with needle release of the A1 pulley combined with corticosteroid injection (combination group). Visual analog scale (VAS), Froimson scale, postoperative recurrence rate, and thickness of A1 pulley at baseline, Week-2, Week-12, and Month-6 were recorded. Results Higher clinical cure rates were observed in the combination group at Week-2 after treatment among patients with the Froimson scale Grade III and IV (p < 0.05). Among Froimson scale Grade IV patients, the combination group had a significantly thinner thickness of A1 pulley and better articular pain relief at Week-2 (all p < 0.05). No significant differences were found in the clinical cure rate, the thickness of the A1 pulley, articular pain relief, and recurrence rate between the two groups at Week-12 and Month-6 (all p > 0.05). Conclusions Ultrasonography-guided needle release of A1 pulley plus corticosteroid injection was superior to ultrasonography-guided A1 pulley needle release alone during early-stage treatment of severe patients with trigger fingers. Moreover, ultrasonography-guided A1 pulley needle release combined with corticosteroid injection narrows the thickness of the A1 pulley. It is necessary to carry out preoperative evaluation and individualized treatment for patients of various severities.
引用
收藏
页数:7
相关论文
共 40 条
  • [31] Effectiveness of ultrasound-guided corticosteroid injection in the treatment of Morton's neuroma
    Markovic, Maja
    Crichton, Ken
    Read, John W.
    Lam, Peter
    Slater, Henry Kim
    FOOT & ANKLE INTERNATIONAL, 2008, 29 (05) : 483 - 487
  • [32] Open Surgery Versus Ultrasound-Guided Corticosteroid Injection for Trigger Finger: A Randomized Controlled Trial With 1-Year Follow-up
    Hansen, Rehne L.
    Sondergaard, Morten
    Lange, Jeppe
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (05): : 359 - 366
  • [33] Percutaneous ultrasound guided A1 pulley release. Part II: Intravaginal technique
    Rojo Manaute, J. M.
    Igualada Blazquez, C.
    Lopez Soto, V
    de las Heras Sanchez-Heredero, J.
    Del Cerro Gutierrez, M.
    Vaquero Martin, J.
    TRAUMA-SPAIN, 2010, 21 (03): : 141 - 149
  • [34] Percutaneous ultrasound guided A1 pulley release. Part I: Description of the "safe area"
    Igualada Blazquez, C.
    Rojo Manaute, J. M.
    Tabernero Fernandez, J. M.
    Rodriguez Conde, C.
    Del Cerro Gutierrez, M.
    Vaquero Martin, J.
    TRAUMA-SPAIN, 2010, 21 (03): : 136 - 140
  • [35] Clinical Study Between Percutaneous Ultrasound-Guided Release and Open Classic Surgery in Treating Multiple Trigger Fingers
    Yavari, Masoud
    Modaresi, Seyed Masoud
    Hassanpour, Seyed Esmail
    Moosavizadeh, Seyed Mehdi
    Tabrizi, Ali
    ADVANCED BIOMEDICAL RESEARCH, 2023, 12 (01):
  • [36] The effects of ultrasound-guided corticosteroid injection for the treatment of hemiplegic shoulder pain on depression and anxiety in patients with chronic stroke
    Chang, Min Cheol
    INTERNATIONAL JOURNAL OF NEUROSCIENCE, 2017, 127 (11) : 958 - 964
  • [38] Ultrasound-guided percutaneous opening of the A1 pulley with surgical knife on anterograde versus retrograde approach: A comparative cadaver study (40 fingers)
    Pages, Laure
    Cambon, Adeline
    HAND SURGERY & REHABILITATION, 2023, 42 (06) : 512 - 516
  • [39] IMPACT OF CORTICOSTEROID INJECTION SITE ON THE TREATMENT SUCCESS RATE OF TRIGGER FINGER: A PROSPECTIVE STUDY COMPARING ULTRASOUND-GUIDED TRUE INTRA-SHEATH AND TRUE EXTRA-SHEATH INJECTIONS
    Shinomiya, Rikuo
    Sunagawa, Toru
    Nakashima, Yuko
    Yoshizuka, Masaaki
    Adachi, Nobuo
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (09) : 2203 - 2208
  • [40] Prospective evaluation of a novel device for ultrasound-guided percutaneous treatment of carpal tunnel and trigger finger disease. Efficacy and safety of sono-instruments®
    Moungondo, Fabian
    Van Rompaey, Hannah
    Moussa, Mohamad K.
    Schuind, Frederic
    JOURNAL OF ULTRASOUND, 2024, 27 (04) : 873 - 885