Ultrasound-guided needle release of A1 pulley combined with corticosteroid injection is more effective than ultrasound-guided needle release alone in the treatment of trigger finger

被引:3
|
作者
Wu, Yan-Yan
Chen, Kai
He, Fan-Ding
Quan, Jie-Rong
Guo, Xuan-Yan [1 ]
机构
[1] Univ Elect Sci Technol China, Sichuan Acad Med Sci, Sch Med, Dept Ultrason, 32 West Second Sect,First Ring Rd, Chengdu 610072, Sichuan, Peoples R China
关键词
A1; pulley; Corticosteroid injection; Trigger finger; Ultrasonography-guided release;
D O I
10.1186/s12893-022-01665-1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The purpose of the present study was to evaluate the clinical effectiveness of ultrasonography-guided needle release of A1 pulley combined with corticosteroid injection by comparing it with ultrasound-guided needle release of the A1 pulley alone. Methods A total of 49 patients (55 fingers, thumb) with trigger fingers were included in this retrospective study. Twenty-seven fingers were treated with ultrasound-guided needle release of the A1 pulley alone (monotherapy group), and 28 fingers were treated with needle release of the A1 pulley combined with corticosteroid injection (combination group). Visual analog scale (VAS), Froimson scale, postoperative recurrence rate, and thickness of A1 pulley at baseline, Week-2, Week-12, and Month-6 were recorded. Results Higher clinical cure rates were observed in the combination group at Week-2 after treatment among patients with the Froimson scale Grade III and IV (p < 0.05). Among Froimson scale Grade IV patients, the combination group had a significantly thinner thickness of A1 pulley and better articular pain relief at Week-2 (all p < 0.05). No significant differences were found in the clinical cure rate, the thickness of the A1 pulley, articular pain relief, and recurrence rate between the two groups at Week-12 and Month-6 (all p > 0.05). Conclusions Ultrasonography-guided needle release of A1 pulley plus corticosteroid injection was superior to ultrasonography-guided A1 pulley needle release alone during early-stage treatment of severe patients with trigger fingers. Moreover, ultrasonography-guided A1 pulley needle release combined with corticosteroid injection narrows the thickness of the A1 pulley. It is necessary to carry out preoperative evaluation and individualized treatment for patients of various severities.
引用
收藏
页数:7
相关论文
共 40 条
  • [1] Ultrasound-guided needle release of A1 pulley combined with corticosteroid injection is more effective than ultrasound-guided needle release alone in the treatment of trigger finger
    Yan-Yan Wu
    Kai Chen
    Fan-Ding He
    Jie-Rong Quan
    Xuan-Yan Guo
    BMC Surgery, 22
  • [2] Treatment of Trigger finger by ultrasound-guided needle release of a1 pulley: A series of 105 cases
    Chopin, Clement
    Le Guillou, Adrien
    Salmon, Jean Hugues
    Lellouche, Henri
    Richette, Pascal
    Maillet, Jeremy
    JOINT BONE SPINE, 2022, 89 (06)
  • [3] Ultrasound-guided thread versus ultrasound-guided needle release of the A1 pulley: a cadaveric study
    Jengojan, Suren
    Sorgo, Philipp
    Streicher, Johannes
    Snoj, Ziga
    Kasprian, Gregor
    Gruber, Gerlinde
    Bodner, Gerd
    RADIOLOGIA MEDICA, 2024, 129 (10): : 1513 - 1521
  • [4] Ultrasound-Guided A1 Pulley Release A Systematic Review
    Nakagawa, Hirotaka
    Redmond, Travis
    Colberg, Ricardo
    Latzka, Erek
    White, Mia S.
    Bowers, Robert L.
    Sussman, Walter I.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (11) : 2491 - 2499
  • [5] Corticosteroid injection for trigger finger: blinded or ultrasound-guided injection?
    G. S. Cecen
    D. Gulabi
    F. Saglam
    N. U. Tanju
    H. I. Bekler
    Archives of Orthopaedic and Trauma Surgery, 2015, 135 : 125 - 131
  • [6] Safety and efficacy of ultrasound-guided percutaneous A1 pulley release using a needle knife: An anatomical study
    Qiu, Zuyun
    Li, Hui
    Shen, Yifeng
    Jia, Yan
    Sun, Xiaojie
    Zhou, Qiaoyin
    Li, Shiliang
    Zhang, Weiguang
    FRONTIERS IN SURGERY, 2022, 9
  • [7] Ultrasound-Guided Percutaneous Release of A1 Pulley by Using a Needle Knife: A Prospective Study of 41 Cases
    Pan, Min
    Sheng, Shuya
    Fan, Zhiqi
    Lu, Hao
    Yang, Hong
    Yan, Fei
    E, Zhansen
    FRONTIERS IN PHARMACOLOGY, 2019, 10
  • [8] Assessment of short-term response and review of technique of ultrasound-guided percutaneous A1 pulley release for the treatment of trigger finger
    White, Roland Z.
    Sampson, Matthew J.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2021, 65 (06) : 672 - 677
  • [9] Ultrasound-Guided First Annular Pulley Injection for Trigger Finger
    Bodor, Marko
    Flossman, Tiffany
    JOURNAL OF ULTRASOUND IN MEDICINE, 2009, 28 (06) : 737 - 743
  • [10] Ultrasound-guided percutaneous release of the annular pulley in trigger digit
    Rajeswaran, Gajan
    Lee, Justin C.
    Eckersley, Rupert
    Katsarma, Effie
    Healy, Jeremiah C.
    EUROPEAN RADIOLOGY, 2009, 19 (09) : 2232 - 2237