What is bright on T1-weighted MR scans?

被引:0
作者
de Kerviler, E [1 ]
Cuenod, CA [1 ]
Clement, O [1 ]
Halimi, P [1 ]
Frija, G [1 ]
Frija, J [1 ]
机构
[1] Hop St Louis, Serv Radiol, F-75475 Paris 10, France
来源
JOURNAL DE RADIOLOGIE | 1998年 / 79卷 / 02期
关键词
MRI; contrast; relaxation times; artifacts;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The list of entities associated with a high signal intensity on T1-weighted images is extensive and classically includes fat, proteins, hemorrhage, melanin and gadolinium. However, additional entities may be responsible for abnormally high signal intensity on T1-weighted images. These include ion deposition in metabolic disorders, free radicals, increased proton density, flow phenomena, some artifacts, and new contrast agents. The aim of this article is to display both the common and uncommon causes for a high T1 signal intensity and to discuss the underlying mechanisms or attributable pathophysiology for this phenomenon.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 51 条
[31]  
MAEDER PP, 1990, AM J NEURORADIOL, V11, P575
[32]   CALCIFICATION DEMONSTRATED AS HIGH SIGNAL INTENSITY ON T1-WEIGHTED MR-IMAGES OF THE DISKS OF THE LUMBAR SPINE [J].
MAJOR, NM ;
HELMS, CA ;
GENANT, HK .
RADIOLOGY, 1993, 189 (02) :494-496
[33]  
MARK LP, 1991, AM J NEURORADIOL, V12, P529
[34]  
MCALLISTER JD, 1987, AJNR, V13, P249
[35]   ANTERIOR-PITUITARY GLAND IN PREGNANCY - HYPERINTENSITY AT MR [J].
MIKI, Y ;
ASATO, R ;
OKUMURA, R ;
TOGASHI, K ;
KIMURA, I ;
KAWAKAMI, S ;
KONISHI, J .
RADIOLOGY, 1993, 187 (01) :229-231
[36]  
MIROWITZ SA, 1989, AM J NEURORADIOL, V10, P1159
[37]   BASAL GANGLIAL SIGNAL INTENSITY ALTERATIONS - REVERSAL AFTER DISCONTINUATION OF PARENTERAL MANGANESE ADMINISTRATION [J].
MIROWITZ, SA ;
WESTRICH, TJ .
RADIOLOGY, 1992, 185 (02) :535-536
[38]   HYPERINTENSE BASAL GANGLIA ON T1-WEIGHTED MR IMAGES IN PATIENTS RECEIVING PARENTERAL-NUTRITION [J].
MIROWITZ, SA ;
WESTRICH, TJ ;
HIRSCH, JD .
RADIOLOGY, 1991, 181 (01) :117-120
[39]   FUNCTIONAL BRAIN MR-IMAGING BASED ON BOLUS TRACKING WITH A FAST T-2-ASTERISK-SENSITIZED GRADIENT-ECHO METHOD [J].
MOONEN, CTW ;
BARRIOS, FA ;
ZIGUN, JR ;
GILLEN, J ;
LIU, GY ;
SOBERING, G ;
SEXTON, R ;
WOO, J ;
FRANK, J ;
WEINBERGER, DR .
MAGNETIC RESONANCE IMAGING, 1994, 12 (03) :379-385
[40]   HIGH-INTENSITY AREAS ON NONCONTRAST T1-WEIGHTED MR IMAGES IN CEREBRAL INFARCTION [J].
NABATAME, H ;
FUJIMOTO, N ;
NAKAMURA, K ;
IMURA, Y ;
DODO, Y ;
FUKUYAMA, H ;
KIMURA, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (04) :521-526