What is bright on T1-weighted MR scans?

被引:0
作者
de Kerviler, E [1 ]
Cuenod, CA [1 ]
Clement, O [1 ]
Halimi, P [1 ]
Frija, G [1 ]
Frija, J [1 ]
机构
[1] Hop St Louis, Serv Radiol, F-75475 Paris 10, France
来源
JOURNAL DE RADIOLOGIE | 1998年 / 79卷 / 02期
关键词
MRI; contrast; relaxation times; artifacts;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The list of entities associated with a high signal intensity on T1-weighted images is extensive and classically includes fat, proteins, hemorrhage, melanin and gadolinium. However, additional entities may be responsible for abnormally high signal intensity on T1-weighted images. These include ion deposition in metabolic disorders, free radicals, increased proton density, flow phenomena, some artifacts, and new contrast agents. The aim of this article is to display both the common and uncommon causes for a high T1 signal intensity and to discuss the underlying mechanisms or attributable pathophysiology for this phenomenon.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 51 条
[1]   PELVIC ENDOMETRIOSIS - MR IMAGING [J].
ARRIVE, L ;
HRICAK, H ;
MARTIN, MC .
RADIOLOGY, 1989, 171 (03) :687-692
[2]   HUMAN-MALIGNANT MELANOMAS WITH VARYING DEGREES OF MELANIN CONTENT IN NUDE-MICE - MR IMAGING, HISTOPATHOLOGY, AND ELECTRON-PARAMAGNETIC RESONANCE [J].
ATLAS, SW ;
BRAFFMAN, BH ;
LOBRUTTO, R ;
ELDER, DE ;
HERLYN, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (04) :547-554
[3]   CALCIFIED INTRACRANIAL LESIONS - DETECTION WITH GRADIENT-ECHO-ACQUISITION RAPID MR IMAGING [J].
ATLAS, SW ;
GROSSMAN, RI ;
HACKNEY, DB ;
GOMORI, JM ;
CAMPAGNA, N ;
GOLDBERG, HI ;
BILANIUK, LT ;
ZIMMERMAN, RA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (06) :1383-1389
[4]   ANALYSIS OF MACHINE-DEPENDENT AND OBJECT-INDUCED GEOMETRIC DISTORTION IN 2DFT MR IMAGING [J].
BAKKER, CJG ;
MOERLAND, MA ;
BHAGWANDIEN, R ;
BEERSMA, R .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :597-608
[5]  
BANGERT BA, 1995, RADIOLOGY, V195, P325
[6]   HIGH SIGNAL INTENSITY LESIONS OF THE CHEST IN MR IMAGING [J].
BARAKOS, JA ;
BROWN, JJ ;
BRESCIA, RJ ;
HIGGINS, CB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (05) :797-802
[7]   A REVIEW OF H-1 NUCLEAR-MAGNETIC-RESONANCE RELAXATION IN PATHOLOGY - ARE T1 AND T2 DIAGNOSTIC [J].
BOTTOMLEY, PA ;
HARDY, CJ ;
ARGERSINGER, RE ;
ALLENMOORE, G .
MEDICAL PHYSICS, 1987, 14 (01) :1-37
[8]  
BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
[9]  
BOYKO OB, 1992, AM J NEURORADIOL, V13, P1439
[10]   THE APPEARANCE OF RAPIDLY FLOWING BLOOD ON MAGNETIC-RESONANCE IMAGES [J].
BRADLEY, WG ;
WALUCH, V ;
LAI, KS ;
FERNANDEZ, EJ ;
SPALTER, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1167-1174