Robust, Low Cost Indoor Positioning Using Magnetic Resonant Coupling

被引:0
作者
Pirkl, Gerald [1 ]
Lukowicz, Paul [2 ]
机构
[1] Univ Passau, Embedded Syst Lab, Passau, Germany
[2] German Res Ctr Artificial Intelligence DFKI, Embedded Intelligence, Saarbrucken, Germany
来源
UBICOMP'12: PROCEEDINGS OF THE 2012 ACM INTERNATIONAL CONFERENCE ON UBIQUITOUS COMPUTING | 2012年
关键词
Oscillating Magnetic Fields; Localization; Scheduling; Sensor Networks; H.3.4 Systems and Software; TIME SYNCHRONIZATION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
We describe the design, implementation, and evaluation of an indoor positioning system based on resonant magnetic coupling. The system has an accuracy of less than 1 m(2) and, because of the underlying physical principle, is robust with respect to disturbances such as people moving around or changes in room configuration. It consists of 16x16x16 cm transmitter coils, each able to cover an area of up to 50 m(2), and provides location information to an arbitrary number of mobile receivers with an update rate of up to 30Hz. We evaluate the actual accuracy of the positioning with a robotic arm and show quantitatively that even large metallic objects have little effect on the signal. We then present an elaborate study of the performance of our system for the recognition of abstract locations such as "at the table", "in front of a cabinet". It comprises four different sites with a total of 100 individual locations some as little as 50 cm apart.
引用
收藏
页码:431 / 440
页数:10
相关论文
共 20 条
  • [1] [Anonymous], 2010, P 8 ACM C EMB NETW S
  • [2] A NEW DISTRIBUTED DEPTH-1ST-SEARCH ALGORITHM
    AWERBUCH, B
    [J]. INFORMATION PROCESSING LETTERS, 1985, 20 (03) : 147 - 150
  • [3] Bahl P., 2000, Proceedings IEEE INFOCOM 2000. Conference on Computer Communications. Nineteenth Annual Joint Conference of the IEEE Computer and Communications Societies (Cat. No.00CH37064), P775, DOI 10.1109/INFCOM.2000.832252
  • [4] PROBABILISTIC CLOCK SYNCHRONIZATION
    CRISTIAN, F
    [J]. DISTRIBUTED COMPUTING, 1989, 3 (03) : 146 - 158
  • [5] Gruenen J.V., 2003, Wsna
  • [6] Hamaguchi A, 2006, TENTH IEEE INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS, PROCEEDINGS, P55
  • [7] Hanser Friedrich, 2008, 2008 Second International Conference on Pervasive Computing Technologies for Healthcare (PervasiveHealth), P279, DOI 10.1109/PCTHEALTH.2008.4571090
  • [8] Wireless power transfer via strongly coupled magnetic resonances
    Kurs, Andre
    Karalis, Aristeidis
    Moffatt, Robert
    Joannopoulos, J. D.
    Fisher, Peter
    Soljacic, Marin
    [J]. SCIENCE, 2007, 317 (5834) : 83 - 86
  • [9] LaMarca A, 2005, LECT NOTES COMPUT SC, V3468, P116
  • [10] Lourens R., 2008, LOW FREQUENCY MAGNET