Amperometric biosensor based on immobilized acetylcholinesterase on gold nanoparticles and silk fibroin modified platinum electrode for detection of methyl paraoxon, carbofuran and phoxim

被引:70
作者
Yin, Huanshun [1 ]
Ai, Shiyun [1 ]
Xu, Jing [1 ]
Shi, Weijie [1 ]
Zhu, Lusheng [2 ]
机构
[1] Shandong Agr Univ, Coll Chem & Mat Sci, Tai An 271018, Shandong, Peoples R China
[2] Shandong Agr Univ, Coll Resources & Environm, Tai An 271018, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Acetylcholinesterase; Gold nanoparticle; Biosensor; Methyl paraoxon; Carbofuran; Phoxim; PESTICIDE SENSITIVITY; LIQUID-CHROMATOGRAPHY; ENZYME ELECTRODE; CARBARYL; THIOCHOLINE; INHIBITION; SENSORS;
D O I
10.1016/j.jelechem.2009.09.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new sensitive and stable amperometric biosensor for the detection of methyl paraoxon, carbofuran and phoxim had been developed based on immobilization of acetylcholinasterase (AChE) on gold nanoparticles (AuNPs) and silk fibroin (SF) modified platinum electrode. The SF provided a biocompatible microenvironment around the enzyme molecule to stabilize its biological activity and effectively prevented it from leaking out of platinum electrode surface. In the presence of acetylthiocholine chloride (ATCl) as a substrate, AuNPs promoted electron transfer reaction at a lower potential and catalyzed the electrochemical oxidation of thiocholine (TCh), thus increasing detection sensitivity. The influences of pH, enzyme loading, temperature and inhibition time on the response of the fabricated biosensor were investigated. Under optimum conditions, the inhibition percentages of methyl paraoxon, carbofuran and phoxim were proportional to their concentrations in the range of 6 x 10(-11)-5 x 10(-8) M. 2 x 10(-10)-1 X 10(-7) M and 5 x 10(-9)-2 x 10(-7) M, respectively. The detection limits were found to be 2 x 10(-11) M for methyl paraoxon, 1x 10(-10) M for carbofuran and 2 x 10(-9) M for phoxim. Moreover. the fabricated biosensor had good reproducibility and acceptable stability. The biosensor is a promising new tool for pesticide analysis. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 50 条
  • [21] Acetylcholinesterase biosensor based on a gold nanoparticle-polypyrrole-reduced graphene oxide nanocomposite modified electrode for the amperometric detection of organophosphorus pesticides
    Yang, Yuqi
    Asiri, Abdullah Mohamed
    Du, Dan
    Lin, Yuehe
    ANALYST, 2014, 139 (12) : 3055 - 3060
  • [22] A Sensitive Amperometric Acetylcholine Biosensor Based on Carbon Nanosphere and Acetylcholinesterase Modified Electrode for Detection of Pesticide Residues
    Cai, Jian-Rong
    Zhou, Li-Na
    Han, En
    ANALYTICAL SCIENCES, 2014, 30 (06) : 669 - 673
  • [23] An acetylcholinesterase-based biosensor for isoprocarb using a gold nanoparticles-polyaniline modified graphite pencil electrode
    Anita Rachmawati
    Afiten Rahmin Sanjaya
    Yulia Mariana Tesa Ayudia Putri
    Jarnuzi Gunlazuardi
    Tribidasari A. Ivandini
    Analytical Sciences, 2023, 39 : 911 - 923
  • [24] Amperometric acetylthiocholine sensor based on acetylcholinesterase immobilized on nanostructured polymer membrane containing gold nanoparticles
    Marinov, Ivaylo
    Ivanov, Yavor
    Gabrovska, Katya
    Godjevargova, Tzonka
    JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2010, 62 (01) : 67 - 75
  • [25] Acetylcholinesterase biosensor based on 3-carboxyphenylboronic acid/reduced graphene oxide-gold nanocomposites modified electrode for amperometric detection of organophosphorus and carbamate pesticides
    Liu, Tao
    Su, Haichao
    Qu, Xiangjin
    Ju, Peng
    Cui, Lin
    Ai, Shiyun
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01): : 1255 - 1261
  • [26] An amperometric urea biosensor based on covalently immobilized urease on an electrode made of hyperbranched polyester functionalized gold nanoparticles
    Tiwari, Ashutosh
    Aryal, Santosh
    Pilla, Srikanth
    Gong, Shaoqin
    TALANTA, 2009, 78 (4-5) : 1401 - 1407
  • [27] Development of an acetylcholinesterase immobilized flow through amperometric detector based on thiocholine detection at a silver electrode
    Parsajoo, Cobra
    Kauffmann, Jean-Michel
    TALANTA, 2013, 109 : 116 - 120
  • [28] Amperometric Biosensor Based on Diamine Oxidase/Platinum Nanoparticles/Graphene/Chitosan Modified Screen-Printed Carbon Electrode for Histamine Detection
    Apetrei, Irina Mirela
    Apetrei, Constantin
    SENSORS, 2016, 16 (04):
  • [29] Amperometric hydrogen peroxide biosensor based on a modified gold electrode with silver nanowires
    Song, Min-Jung
    Hwang, Sung Woo
    Whang, Dongmok
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (12) : 2099 - 2105
  • [30] AMPEROMETRIC IMMUNOSENSOR BASED ON L-CYSTEINE/GOLD COLLOIDAL NANOPARTICLES FOR CARBOFURAN DETECTION
    Du, Shuyuan
    Wang, Xiangyou
    Sun, Xia
    Li, Qingqing
    ANALYTICAL LETTERS, 2012, 45 (10) : 1230 - 1241