Study of the influence of the electric field on membrane flux of a new type of membrane bioreactor

被引:87
作者
Chen, Jun-Ping [1 ]
Yang, Chang-Zhu
Zhou, Jia-Hua
Wang, Xiao-Ying
机构
[1] Hubei Univ Technol, Sch Chem & Envrionm Engn, Wuhan 430068, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Environm Sci & Engn, Wuhan 430074, Peoples R China
[3] Guangdong Univ Technol, Fac Chem Engn & Light Ind, Guangzhou 510090, Guangdong, Peoples R China
关键词
electric field; membrane flux; membrane bioreactor; anti-fouling; CROSS-FLOW;
D O I
10.1016/j.cej.2006.10.010
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The effect of appending direct electric field on the membrane flux of an antifouling membrane bioreactor (MBR) designed and built in our laboratory was investigated. The results showed that appending electric field had significant influence on the membrane flux. At an operation pressure of Delta P = 0.1 MPa, membrane flux increased with electric field strength from E = 15 V/cm to 20 V/cm, then kept almost constant after E arrived 20 V/cm. This might result from the fact that charged coarse particle and colloid accounted for 80% of CODCr and BOD5 in urban domestic sewage. Those particles and colloid moved away from the membrane surface in the electric field and their speed increased with the increase of electric field strength. When the electric field strength was strong enough to make the deposited layer on the membrane surface no longer a limiting factor in the membrane flux, no much effect was observed after the electric field strength exceeded the critical point. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:177 / 180
页数:4
相关论文
共 17 条
  • [1] SOLID-LIQUID SEPARATION PROCESS BASED ON CROSS FLOW AND ELECTROFILTRATION
    HENRY, JD
    LAWLER, LF
    KUO, CHA
    [J]. AICHE JOURNAL, 1977, 23 (06) : 851 - 859
  • [2] Fouling control in activated sludge submerged hollow fiber membrane bioreactors
    Hong, SP
    Bae, TH
    Tak, TM
    Hong, S
    Randall, A
    [J]. DESALINATION, 2002, 143 (03) : 219 - 228
  • [3] JOSEPH D, 1997, AICHE J, V23, P851
  • [4] APPLICATION OF ELECTRIC-FIELDS AND VORTEX MIXING FOR ENHANCED ULTRAFILTRATION
    JURADO, J
    BELLHOUSE, BJ
    [J]. FILTRATION & SEPARATION, 1994, 31 (03): : 273 - 281
  • [5] LIU SH, 1999, MEMBR SCI TECHNOL, V19, P13
  • [6] RADOVIOH JM, 1982, J COATING TECHNOL, V695, P33
  • [7] STUMPE M, 1993, FILTRATION SEPAR JUN, P331
  • [8] Tarleton E.S., 1992, Filbabon Separabon, V29, P246
  • [9] TARLETON ES, 1992, FILTRATION SEPAR SEP, P425
  • [10] MEMBRANE FOULING PREVENTION IN CROSS-FLOW MICROFILTRATION BY THE USE OF ELECTRIC-FIELDS
    WAKEMAN, RJ
    TARLETON, ES
    [J]. CHEMICAL ENGINEERING SCIENCE, 1987, 42 (04) : 829 - 842