Benchmarking BrachyDose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters

被引:138
作者
Taylor, R. E. P. [1 ]
Yegin, G. [1 ]
Rogers, D. W. O. [1 ]
机构
[1] Carleton Univ, Ottawa Carleton Inst Phys, Ottawa, ON K1S 5B6, Canada
关键词
D O I
10.1118/1.2400843
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, BrachyDose, a recently developed EGSnre Monte Carlo code for rapid brachytherapy dose calculations, has been benchmarked by reproducing previously published dosimetry parameters for three brachytherapy seeds with varied internal structure and encapsulation. Calculations are performed for two I-125 seeds (Source Tech Medical Model STM1251 and Imagyn isoSTAR model 12501) and one Pd-103 source (Theragenics Model 200). Voxel size effects were investigated with dose distribution calculations for three voxel sizes: 0.1 X 0.1 X 0.1 mm(3), 0.5 X 0.5 X 0.5 mm(3), and 1 X I X I mm3. In order to minimize the impact of voxel size effects, tabulated dosimetry data for this study consist of a combination of the three calculations: 0.1 X 0.1 X 0.1 mm(3) voxels for distances in the range of 0 < r <= 1 cm, 0.5 X 0.5 X 0.5 mm(3) voxels for 1 < r <= 5 cm and 1 X 1 X 1 mm(3) voxels for 5 < r <= 10 cm. Dosimetry parameters from this study are compared with values calculated by other authors using Williamson's PTRAN code and to measured values. Overall, calculations made with Brachydose show good agreement with calculations made with PTRAN although there are some exceptions. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:445 / 457
页数:13
相关论文
共 39 条
[1]  
[Anonymous], 1987, NBSIR873597 NIST
[2]   Anisotropy functions for low energy interstitial brachytherapy sources:: an EGS4 Monte Carlo study [J].
Capote, R ;
Mainegra, E ;
López, E .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (01) :135-150
[3]   Dose rate constant and energy spectrum of interstitial brachytherapy sources [J].
Chen, Z ;
Nath, R .
MEDICAL PHYSICS, 2001, 28 (01) :86-96
[4]   Thermoluminescent dosimetry of the SourceTech Medical model STM125l 125I seed [J].
Chiu-Tsao, ST ;
Duckworth, TL ;
Hsiung, CY ;
Li, ZF ;
Williamson, J ;
Patel, NS ;
Harrison, LB .
MEDICAL PHYSICS, 2003, 30 (07) :1732-1735
[5]   Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts [J].
Das, RK ;
Li, Z ;
Perera, H ;
Williamson, JF .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (06) :995-1006
[6]  
Davis SD, 2003, RADIAT PROT DOSIM, V106, P33, DOI 10.1093/oxfordjournals.rpd.a006332
[7]   Dosimetric characteristics of a new 125I brachytherapy source [J].
Gearheart, DM ;
Drogin, A ;
Sowards, K ;
Meigooni, AS ;
Ibbott, GS .
MEDICAL PHYSICS, 2000, 27 (10) :2278-2285
[8]   Monte Carlo determination of dose rate constant [J].
Ibbott, GS ;
Meigooni, AS ;
Gearheart, DM .
MEDICAL PHYSICS, 2002, 29 (07) :1637-1638
[9]   Dose-rate constant for Imagyn 125I brachytherapy source [J].
Ibbott, GS ;
Nath, R .
MEDICAL PHYSICS, 2001, 28 (04) :705-705
[10]   Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version [J].
Kawrakow, I .
MEDICAL PHYSICS, 2000, 27 (03) :485-498