Salvage of Monoblock Metal-on-Metal Acetabular Components Using a Dual-Mobility Bearing

被引:27
作者
Plummer, Darren R. [1 ]
Botero, Herman G. [2 ]
Berend, Keith R. [3 ]
Pritchett, James W. [4 ]
Lombardi, Adolph V. [3 ]
Della Valle, Craig J. [5 ]
机构
[1] Ohio State Univ, Wexner Med Ctr, Dept Orthopaed Surg, 376 West 10th Ave,725 Prior Hall, Columbus, OH 43210 USA
[2] Knoxville Orthopaed Clin, Knoxville, TN USA
[3] Joint Implant Surg, New Albany, IN USA
[4] Swedish Med Ctr, Seattle, WA USA
[5] Midwest Orthopaed Rush, Chicago, IL USA
关键词
total hip arthroplasty; bearing surfaces; revision total hip arthroplasty; salvage monoblock metal-on-metal; adverse local tissue reaction; metal-on-metal; TOTAL HIP-ARTHROPLASTY; NATIONAL JOINT REGISTRY; REVISION; SURVIVAL; FAILURE; SOCKET;
D O I
10.1016/j.arth.2015.08.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Large-diameter, monoblock acetabular components have been used for both hip resurfacing arthroplasty and metal-on-metal (MoM) total hip arthroplasty (THA). If revision is required, one solution is to retain the shell and use a dual-mobility bearing. Methods: We reviewed the results of 25 revision THAs including 11 hip resurfacing arthroplasty and 14 MoM THAs where a monoblock acetabular component was mated to a dual-mobility bearing. Results: At amean of 29 months, there was one failure, an intraprosthetic dislocation of the dual-mobility bearing. There was a significant decrease in serum metal ion levels postoperatively. Conclusion: Retention of a well-fixed, monoblock MoM acetabular shell and mating it to a dual-mobility bearing in the setting of revision surgery seems to be a reasonable, low-morbidity option at short-term follow-up in appropriately positioned cups. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:846 / 849
页数:4
相关论文
共 37 条
[1]   Dislocationm after revision total hip arthroplasty - An analysis of risk factors and treatment options [J].
Alberton, GM ;
High, WA ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) :1788-1792
[2]   Complications After Metal-on-Metal Hip Resurfacing Arthroplasty [J].
Amstutz, Harlan C. ;
Le Duff, Michel J. ;
Campbell, Patricia A. ;
Wisk, Lauren E. ;
Takamura, Karren M. .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2011, 42 (02) :207-+
[3]   Grading the severity of soft tissue changes associated with metal-on-metal hip replacements: reliability of an MR grading system [J].
Anderson, Helen ;
Toms, Andoni Paul ;
Cahir, John G. ;
Goodwin, Richard W. ;
Wimhurst, James ;
Nolan, John F. .
SKELETAL RADIOLOGY, 2011, 40 (03) :303-307
[4]   Large-Diameter Modular Metal-on-Metal Total Hip Arthroplasty Incidence of Revision for Adverse Reaction to Metallic Debris [J].
Barrett, William P. ;
Kindsfater, Kirk A. ;
Lesko, James P. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :976-983
[5]   The Epidemiology of Bearing Surface Usage in Total Hip Arthroplasty in the United States [J].
Bozic, Kevin J. ;
Kurtz, Steven ;
Lau, Edmund ;
Ong, Kevin ;
Chiu, Vanessa ;
Vail, Thomas P. ;
Rubash, Harry E. ;
Berry, Daniel J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (07) :1614-1620
[6]   Low Rate of Dislocation of Dual-mobility Cups in Primary Total Hip Arthroplasty [J].
Combes, Antoine ;
Migaud, Henri ;
Girard, Julien ;
Duhamel, Alain ;
Fessy, Michel Henri .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (12) :3891-3900
[7]   Birmingham hip resurfacing at a mean of ten years RESULTS FROM AN INDEPENDENT CENTRE [J].
Coulter, G. ;
Young, D. A. ;
Dalziel, R. E. ;
Shimmin, A. J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (03) :315-321
[8]  
Earll MD, 2011, J ARTHROPLASTY, V26, pe335
[9]  
Earll MD, 2011, J ARTHROPLASTY, V26, P338, DOI [10.1016/j.arth.2009.11.006, DOI 10.1016/J.ARTH.2009.11.006]
[10]   Metal-on-Metal Total Hip Arthroplasty: Causes and High Incidence of Early Failure [J].
Fabi, David ;
Levine, Brett ;
Paprosky, Wayne ;
Della Valle, Craig ;
Sporer, Scott ;
Klein, Gregg ;
Levine, Harlan ;
Hartzband, Mark .
ORTHOPEDICS, 2012, 35 (07) :E1009-E1016