Direct immunosensing with an integrated-optical output grating coupler

被引:33
作者
Clerc, D [1 ]
Lukosz, W [1 ]
机构
[1] SWISS FED INST TECHNOL,OPT LAB,CH-8093 ZURICH,SWITZERLAND
关键词
biosensors; immunosensors; integrated-optical sensors; avidin-biotin affinity binding;
D O I
10.1016/S0925-4005(97)80199-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have used an output grating coupler for direct immunosensing. The antigen, a rabbit-IgG, is selectively detected in subnanomolar concentrations in a few minutes by its binding to the corresponding antibodies (goat-anti-rabbit-IgG) immobilized on the waveguide surface. The following immobilization technique of the antibody, which requires no surface chemistry, is used: the waveguide is first coated (by adsorption) with avidin which adheres well on it; in a second step, the biotinylated antibodies are bound irreversibly to the avidin layer by the strong avidin-biotin affinity binding. In order to improve the accuracy of the determined surface mass densities and thus to lower the detection limit, we introduce a new drift-correction method which is based on the simultaneous measurement of both effective refractive indices N-TE0 and N-TM0 of the guided TE0 and TM0 modes. The drift effect is a small and slow but persistent increase of the effective refractive indices N-TE0 and N-TM0 of the somewhat microporous (SiO2-TiO2) waveguides in contact with an aqueous buffer solution with time.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 12 条
[1]   INTEGRATED OPTICAL OUTPUT GRATING COUPLER AS REFRACTOMETER AND (BIO-)CHEMICAL SENSOR [J].
CLERC, D ;
LUKOSZ, W .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) :461-465
[2]  
CLERC D, 1995, THESIS ETH ZURICH
[3]  
CLERC D, 1994, SENSOR ACTUAT B-CHEM, V18, P581
[4]  
DAY ED, 1990, ADV IMMUNOCHEMISTRY
[5]   ELLIPSOMETRY AS A TOOL TO STUDY ADSORPTION BEHAVIOR OF SYNTHETIC AND BIOPOLYMERS AT AIR-WATER-INTERFACE [J].
DEFEIJTER, JA ;
BENJAMINS, J ;
VEER, FA .
BIOPOLYMERS, 1978, 17 (07) :1759-1772
[6]   USE OF BIFUNCTIONAL BIOTINYL COMPOUNDS TO DETERMINE ARRANGEMENT OF SUBUNITS IN AVIDIN [J].
GREEN, NM ;
KONIECZNY, L ;
TOMS, EJ ;
VALENTINE, RC .
BIOCHEMICAL JOURNAL, 1971, 125 (03) :781-+
[7]   PERFORMANCE OF A HIGHLY SENSITIVE OPTICAL WAVE-GUIDE MACH-ZEHNDER INTERFEROMETER IMMUNOSENSOR [J].
HEIDEMAN, RG ;
KOOYMAN, RPH ;
GREVE, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 10 (03) :209-217
[8]  
HEMING M, 1992, MATER RES SOC SYMP P, V276, P117, DOI 10.1557/PROC-276-117
[9]   SENSITIVITY OF INTEGRATED OPTICAL GRATING AND PRISM COUPLERS AS (BIO)CHEMICAL SENSORS [J].
LUKOSZ, W ;
TIEFENTHALER, K .
SENSORS AND ACTUATORS, 1988, 15 (03) :273-284